메뉴 건너뛰기




Volumn 133, Issue 1, 2008, Pages 244-250

Glucose biosensor constructed from capped conducting microtubules of PEDOT

Author keywords

Capping; Enzyme; Glucose biosensor; Imprisonment; Microtubule

Indexed keywords

BIOSENSORS; CELL MEMBRANES; CHEMICAL REACTIONS; CHEMICALS; DETECTORS; ELECTROCHEMICAL ELECTRODES; ELECTROLYSIS; ENZYME SENSORS; ENZYMES; FOOD ADDITIVES; GLUCOSE; GLUCOSE OXIDASE; GOLD; HYDROGEN; HYDROGEN PEROXIDE; METALLIZING; MONOMERS; OPTICAL DESIGN; POLYMERIZATION; POLYMERS; SENSORS; SIGNAL TRANSDUCTION;

EID: 46749113877     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2008.02.029     Document Type: Article
Times cited : (65)

References (18)
  • 1
    • 34248525070 scopus 로고    scopus 로고
    • Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode
    • Li J., and Lin X. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode. Biosens. Bioelectron. 22 (2007) 2898-2905
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 2898-2905
    • Li, J.1    Lin, X.2
  • 2
    • 33747887674 scopus 로고    scopus 로고
    • A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment
    • Shan D., He Y., Wang S., Xue H., and Zheng H. A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment. Anal. Biochem. 356 (2006) 215-221
    • (2006) Anal. Biochem. , vol.356 , pp. 215-221
    • Shan, D.1    He, Y.2    Wang, S.3    Xue, H.4    Zheng, H.5
  • 4
    • 0000842332 scopus 로고
    • Template synthesis of polymeric and metal microtubules
    • Martin C.R. Template synthesis of polymeric and metal microtubules. Adv. Mater. 3 (1991) 457-459
    • (1991) Adv. Mater. , vol.3 , pp. 457-459
    • Martin, C.R.1
  • 5
    • 0028292641 scopus 로고
    • Synthesis of polymeric microcapsule arrays and their use for enzyme immobilization
    • Parthasarathy R.V., and Martin C.R. Synthesis of polymeric microcapsule arrays and their use for enzyme immobilization. Nature 369 (1994) 298-301
    • (1994) Nature , vol.369 , pp. 298-301
    • Parthasarathy, R.V.1    Martin, C.R.2
  • 7
    • 33744917039 scopus 로고    scopus 로고
    • Conducting polymer micro-tubules hosting electroactive species without guest modification
    • Park J., Kim J., and Son Y. Conducting polymer micro-tubules hosting electroactive species without guest modification. Synth. Met. 156 (2006) 714-720
    • (2006) Synth. Met. , vol.156 , pp. 714-720
    • Park, J.1    Kim, J.2    Son, Y.3
  • 8
    • 0026628622 scopus 로고
    • Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials
    • Chen C.-Y., Goto M., Makino H., Su Y.-C., Tamiya E., and Karube I. Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials. Anal. Chim. Acta 265 (1992) 5-14
    • (1992) Anal. Chim. Acta , vol.265 , pp. 5-14
    • Chen, C.-Y.1    Goto, M.2    Makino, H.3    Su, Y.-C.4    Tamiya, E.5    Karube, I.6
  • 9
    • 0034093802 scopus 로고    scopus 로고
    • Glow-discharge-treated cellulose acetate (CA) membrane for a high linearity single-layer glucose electrode in the food industry
    • Alp B., Mutlu S., and Mutlu M. Glow-discharge-treated cellulose acetate (CA) membrane for a high linearity single-layer glucose electrode in the food industry. Food Res. Int. 33 (2000) 107-112
    • (2000) Food Res. Int. , vol.33 , pp. 107-112
    • Alp, B.1    Mutlu, S.2    Mutlu, M.3
  • 10
    • 0029745329 scopus 로고    scopus 로고
    • A Clark-type oxidase enzyme-based amperometric microbiosensor for sensing glucose, galactose, or choline
    • Peteu S.F., Emerson D., and Worden R.M. A Clark-type oxidase enzyme-based amperometric microbiosensor for sensing glucose, galactose, or choline. Biosens. Bioelectron. 11 (1996) 1059-1071
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 1059-1071
    • Peteu, S.F.1    Emerson, D.2    Worden, R.M.3
  • 11
    • 0030033014 scopus 로고    scopus 로고
    • Electrochemical characterization of polypyrrole/glucose oxidase biosensor. Part II. Optimal preparation conditions for the biosensor
    • Shin M.-C., and Kim H.-S. Electrochemical characterization of polypyrrole/glucose oxidase biosensor. Part II. Optimal preparation conditions for the biosensor. Biosens. Bioelectron. 11 (1996) 171-178
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 171-178
    • Shin, M.-C.1    Kim, H.-S.2
  • 12
    • 18344396429 scopus 로고    scopus 로고
    • Carbon-nanotubes doped polypyrrole glucose biosensor
    • Wang J., and Musameh M. Carbon-nanotubes doped polypyrrole glucose biosensor. Anal. Chim. Acta 539 (2005) 209-213
    • (2005) Anal. Chim. Acta , vol.539 , pp. 209-213
    • Wang, J.1    Musameh, M.2
  • 13
    • 8744232097 scopus 로고    scopus 로고
    • Highly sensitive amperometric glucose biosensor based on glassy carbon electrode with copper/palladium coating
    • Dai Y.-Q., and Shiu K.-K. Highly sensitive amperometric glucose biosensor based on glassy carbon electrode with copper/palladium coating. Electroanalysis 16 (2004) 1806-1813
    • (2004) Electroanalysis , vol.16 , pp. 1806-1813
    • Dai, Y.-Q.1    Shiu, K.-K.2
  • 14
    • 2342470000 scopus 로고    scopus 로고
    • In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor
    • Zimmermann S., Fienbork D., Flounders A.W., and Liepmann D. In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor. Sens. Actuators B 99 (2004) 163-173
    • (2004) Sens. Actuators B , vol.99 , pp. 163-173
    • Zimmermann, S.1    Fienbork, D.2    Flounders, A.W.3    Liepmann, D.4
  • 15
    • 2342573708 scopus 로고    scopus 로고
    • Multifunctional biocompatible membrane and its application to fabricate a miniaturized glucose sensor with potential for use in vivo
    • Chen C.-Y., Ishihara K., Nakabayashi N., Tamiya E., and Karube I. Multifunctional biocompatible membrane and its application to fabricate a miniaturized glucose sensor with potential for use in vivo. Biomed. Microdevices 1 (1999) 155-166
    • (1999) Biomed. Microdevices , vol.1 , pp. 155-166
    • Chen, C.-Y.1    Ishihara, K.2    Nakabayashi, N.3    Tamiya, E.4    Karube, I.5
  • 16
    • 1942470076 scopus 로고    scopus 로고
    • Using electropolymerized non-conducting polymers to develop enzyme amperometric biosensors
    • Yuqing M., Jianrong C., and Xiaohua W. Using electropolymerized non-conducting polymers to develop enzyme amperometric biosensors. Trends Biotechnol. 22 (2004) 227-231
    • (2004) Trends Biotechnol. , vol.22 , pp. 227-231
    • Yuqing, M.1    Jianrong, C.2    Xiaohua, W.3
  • 17
    • 0026147814 scopus 로고
    • Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film
    • Fortier G., and Bélanger D. Characterization of the biochemical behavior of glucose oxidase entrapped in a polypyrrole film. Biotechnol. Bioeng. 37 (1991) 854-858
    • (1991) Biotechnol. Bioeng. , vol.37 , pp. 854-858
    • Fortier, G.1    Bélanger, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.