메뉴 건너뛰기




Volumn 34, Issue 2, 2008, Pages 350-353

Do repeated runs of a cell saver device increase the pro-inflammatory properties of washed blood?

Author keywords

Blood quality; Cardiac surgery; Cell saver; Interleukins

Indexed keywords

HEMOGLOBIN; HEPARIN; INTERLEUKIN 6;

EID: 46749112578     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2008.05.004     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0032799238 scopus 로고    scopus 로고
    • Influence of different autotransfusion devices on the quality of salvaged blood
    • Reents W., Babin-Ebell J., Misoph M.R., Schwarzkopf A., and Elert O. Influence of different autotransfusion devices on the quality of salvaged blood. Ann Thorac Surg 68 (1999) 58-62
    • (1999) Ann Thorac Surg , vol.68 , pp. 58-62
    • Reents, W.1    Babin-Ebell, J.2    Misoph, M.R.3    Schwarzkopf, A.4    Elert, O.5
  • 2
    • 0028941017 scopus 로고
    • Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis
    • de Haan J., Boonstra P.W., Monnink S.H., Ebels T., and van Oeveren W. Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis. Ann Thorac Surg 59 (1995) 901-907
    • (1995) Ann Thorac Surg , vol.59 , pp. 901-907
    • de Haan, J.1    Boonstra, P.W.2    Monnink, S.H.3    Ebels, T.4    van Oeveren, W.5
  • 3
    • 10444235016 scopus 로고    scopus 로고
    • Influence of pericardial suction blood retransfusion on memory function and release of protein S100B
    • Svenmarker S., Engstrom K.G., Karlsson T., Jansson E., Lindholm R., and Aberg T. Influence of pericardial suction blood retransfusion on memory function and release of protein S100B. Perfusion 19 (2004) 337-343
    • (2004) Perfusion , vol.19 , pp. 337-343
    • Svenmarker, S.1    Engstrom, K.G.2    Karlsson, T.3    Jansson, E.4    Lindholm, R.5    Aberg, T.6
  • 5
    • 0036203167 scopus 로고    scopus 로고
    • Levels of inflammatory markers in the blood processed by autotransfusion devices during cardiac surgery associated with cardiopulmonary bypass circuit
    • Amand T., Pincemail J., Blaffart F., Larbuisson R., Limet R., and Defraigne J.O. Levels of inflammatory markers in the blood processed by autotransfusion devices during cardiac surgery associated with cardiopulmonary bypass circuit. Perfusion 17 (2002) 117-123
    • (2002) Perfusion , vol.17 , pp. 117-123
    • Amand, T.1    Pincemail, J.2    Blaffart, F.3    Larbuisson, R.4    Limet, R.5    Defraigne, J.O.6
  • 7
    • 0031467551 scopus 로고    scopus 로고
    • Interindividual variations in cytokine levels following cardiopulmonary bypass
    • Misoph M., and Babin-Ebell J. Interindividual variations in cytokine levels following cardiopulmonary bypass. Heart Vessels 12 (1997) 119-127
    • (1997) Heart Vessels , vol.12 , pp. 119-127
    • Misoph, M.1    Babin-Ebell, J.2
  • 8
    • 33846900657 scopus 로고    scopus 로고
    • Washing of stored red blood cells by an autotransfusion device before transfusion
    • de Vroege R., Wildevuur W.R., Muradin J.A.G., Graves D., and van Oeveren W. Washing of stored red blood cells by an autotransfusion device before transfusion. Vox Sang 92 (2007) 130-135
    • (2007) Vox Sang , vol.92 , pp. 130-135
    • de Vroege, R.1    Wildevuur, W.R.2    Muradin, J.A.G.3    Graves, D.4    van Oeveren, W.5
  • 9
    • 0028916674 scopus 로고
    • Leucocyte content in blood processed by autotransfusion devices during open-heart surgery
    • Perttila J., Leino L., Poyhonen M., and Salo M. Leucocyte content in blood processed by autotransfusion devices during open-heart surgery. Acta Anaesthesiol Scand 39 (1995) 445-448
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 445-448
    • Perttila, J.1    Leino, L.2    Poyhonen, M.3    Salo, M.4
  • 10
    • 0023693754 scopus 로고
    • Clinical implications of procoagulant and leukoattractant formation during intraoperative blood salvage
    • Bull M.H., Bull B.S., Van Arsdell G.S., and Smith L.L. Clinical implications of procoagulant and leukoattractant formation during intraoperative blood salvage. Arch Surg 123 (1988) 1073-1078
    • (1988) Arch Surg , vol.123 , pp. 1073-1078
    • Bull, M.H.1    Bull, B.S.2    Van Arsdell, G.S.3    Smith, L.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.