메뉴 건너뛰기




Volumn 29, Issue 6, 2008, Pages 1071-1075

Subtraction 3D CT angiography with the orbital synchronized helical scan technique for the evaluation of postoperative cerebral aneurysms treated with cobalt-alloy clips

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; COBALT;

EID: 46749105566     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1040     Document Type: Article
Times cited : (29)

References (15)
  • 1
    • 33747391589 scopus 로고    scopus 로고
    • Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: Comparison with conventional digital subtraction angiography
    • Sakamoto S, Kiura Y, Shibukawa M, et al. Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: comparison with conventional digital subtraction angiography. AJNR Am J Neuroradiol 2006;27:1332-37
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1332-1337
    • Sakamoto, S.1    Kiura, Y.2    Shibukawa, M.3
  • 2
    • 33644861883 scopus 로고    scopus 로고
    • Bone-subtraction CT angiography for the evaluation of intracranial aneurysms
    • Tomandl BF, Hammen T, Klotz E, et al. Bone-subtraction CT angiography for the evaluation of intracranial aneurysms. AJNR Am J Neuroradiol 2006;27:55-59
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 55-59
    • Tomandl, B.F.1    Hammen, T.2    Klotz, E.3
  • 3
    • 0035116568 scopus 로고    scopus 로고
    • CT angiography of the circle of Willis and intracranial internal carotid arteries: Maximum intensity projection with matched mask bone elimination-feasibility study
    • Venema HW, Hulsmans FJ, den Heeten GJ. CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study. Radiology 2001;218:893-98
    • (2001) Radiology , vol.218 , pp. 893-898
    • Venema, H.W.1    Hulsmans, F.J.2    den Heeten, G.J.3
  • 4
    • 0032471416 scopus 로고    scopus 로고
    • Subtraction CT angiography with controlled-orbit helical scanning for detection of intracranial aneurysms
    • Imakita S, Onishi Y, Hashimoto T, et al. Subtraction CT angiography with controlled-orbit helical scanning for detection of intracranial aneurysms. AJNR Am J Neuroradiol 1998;19:291-95
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 291-295
    • Imakita, S.1    Onishi, Y.2    Hashimoto, T.3
  • 5
    • 33644651307 scopus 로고    scopus 로고
    • Comparison of multislice computerized tomography angiography and digital subtraction angiography in the postoperative evaluation of patients with clipped aneurysms
    • Dehdashti AR, Binaghi S, Uske A, et al. Comparison of multislice computerized tomography angiography and digital subtraction angiography in the postoperative evaluation of patients with clipped aneurysms. J Neurosurg 2006;104:395-403
    • (2006) J Neurosurg , vol.104 , pp. 395-403
    • Dehdashti, A.R.1    Binaghi, S.2    Uske, A.3
  • 6
    • 33646516008 scopus 로고    scopus 로고
    • Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: Detection with single detector CT - comparison with intra-arterial digital subtraction angiography
    • Sakuma I, Tomura N, Kinouchi H, et al. Postoperative three-dimensional CT angiography after cerebral aneurysm clipping with titanium clips: detection with single detector CT - comparison with intra-arterial digital subtraction angiography. Clin Radiol 2006;61:505-12
    • (2006) Clin Radiol , vol.61 , pp. 505-512
    • Sakuma, I.1    Tomura, N.2    Kinouchi, H.3
  • 7
    • 16544368352 scopus 로고    scopus 로고
    • Multi-slice computed tomography angiography in the detection of residual or recurrent cerebral aneurysms after surgical clipping
    • Teksam M, McKinney A, Cakir B, et al. Multi-slice computed tomography angiography in the detection of residual or recurrent cerebral aneurysms after surgical clipping. Acta Radiol 2004;45:571-76
    • (2004) Acta Radiol , vol.45 , pp. 571-576
    • Teksam, M.1    McKinney, A.2    Cakir, B.3
  • 8
    • 32044470061 scopus 로고    scopus 로고
    • Limitations of three-dimensional reconstructed computerized tomography angiography after clip placement for intracranial aneurysms
    • Sagara Y, Kiyosue H, Hori Y, et al. Limitations of three-dimensional reconstructed computerized tomography angiography after clip placement for intracranial aneurysms. J Neurosurg 2005;103:656-61
    • (2005) J Neurosurg , vol.103 , pp. 656-661
    • Sagara, Y.1    Kiyosue, H.2    Hori, Y.3
  • 9
    • 33750732949 scopus 로고    scopus 로고
    • Multislice computed tomography angiography screening for new aneurysms in patients with previously clip-treated intracranial aneurysms: Feasibility, positive predictive value, and interobserver agreement
    • van der Schaaf IC, Velthuis BK, Wermer MJ, et al. Multislice computed tomography angiography screening for new aneurysms in patients with previously clip-treated intracranial aneurysms: feasibility, positive predictive value, and interobserver agreement. J Neurosurg 2006;105:682-88
    • (2006) J Neurosurg , vol.105 , pp. 682-688
    • van der Schaaf, I.C.1    Velthuis, B.K.2    Wermer, M.J.3
  • 10
    • 0034512148 scopus 로고    scopus 로고
    • What percentage of surgically clipped intracranial aneurysms have residual necks?
    • discussion 1298-1300
    • Thornton J, Bashir Q, Aletich VA, et al. What percentage of surgically clipped intracranial aneurysms have residual necks? Neurosurgery 2000;46:1294-98, discussion 1298-1300
    • (2000) Neurosurgery , vol.46 , pp. 1294-1298
    • Thornton, J.1    Bashir, Q.2    Aletich, V.A.3
  • 11
    • 0034852465 scopus 로고    scopus 로고
    • Risk of aneurysm recurrence in patients with clipped cerebral aneurysms: Results of long-term follow-up angiography - what percentage of surgically clipped intracranial aneurysms have residual necks?
    • Tsutsumi K, Ueki K, Morita A, et al. Risk of aneurysm recurrence in patients with clipped cerebral aneurysms: results of long-term follow-up angiography - what percentage of surgically clipped intracranial aneurysms have residual necks? Stroke 2001;32:1191-94
    • (2001) Stroke , vol.32 , pp. 1191-1194
    • Tsutsumi, K.1    Ueki, K.2    Morita, A.3
  • 12
    • 1042276581 scopus 로고    scopus 로고
    • Yield of screening for new aneurysms after treatment for subarachnoid hemorrhage
    • Wermer MJ, Buskens E, van der Schaaf IC, et al. Yield of screening for new aneurysms after treatment for subarachnoid hemorrhage. Neurology 2004;62:369-75
    • (2004) Neurology , vol.62 , pp. 369-375
    • Wermer, M.J.1    Buskens, E.2    van der Schaaf, I.C.3
  • 13
    • 26044470141 scopus 로고    scopus 로고
    • Follow-up screening after subarachnoid haemorrhage: Frequency and determinants of new aneurysms and enlargement of existing aneurysms
    • Wermer MJ, van der Schaaf IC, Velthuis BK, et al. Follow-up screening after subarachnoid haemorrhage: frequency and determinants of new aneurysms and enlargement of existing aneurysms. Brain 2005;128:2421-29
    • (2005) Brain , vol.128 , pp. 2421-2429
    • Wermer, M.J.1    van der Schaaf, I.C.2    Velthuis, B.K.3
  • 15
    • 0344405731 scopus 로고    scopus 로고
    • Venema HW, den Heeten GJ. Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience - rediscovery of matched mask bone elimination? AJNR Am J Neuroradiol 2003;24:1491, author reply 1491-14
    • Venema HW, den Heeten GJ. Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience - rediscovery of matched mask bone elimination? AJNR Am J Neuroradiol 2003;24:1491, author reply 1491-14


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.