1
-
-
46549083163
-
-
IAEA, 2002. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. IAEA, Vienna, IAEA-DOC-1331, ISBN 92-0-119402-1.
-
IAEA, 2002. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. IAEA, Vienna, IAEA-DOC-1331, ISBN 92-0-119402-1.
-
-
-
-
2
-
-
0034658397
-
New computer procedure for routine EPR-dosimetry on tooth enamel. Description and verification
-
Koshta A.A., Wieser A., Ignatiev E.A., Bayankin S., Romanyukha A.A., and Degteva M.O. New computer procedure for routine EPR-dosimetry on tooth enamel. Description and verification. Appl. Radiat. Isot. 52 (2000) 1287-1290
-
(2000)
Appl. Radiat. Isot.
, vol.52
, pp. 1287-1290
-
-
Koshta, A.A.1
Wieser, A.2
Ignatiev, E.A.3
Bayankin, S.4
Romanyukha, A.A.5
Degteva, M.O.6
-
4
-
-
0343018450
-
The second international intercomparison on EPR tooth dosimetry
-
Wieser A., Mehta K., Amira S., Aragno D., Bercea S., Brik A., Bugai A., Callens F., Chumak V., Ciesielski B., Debuyst R., Dubovsky S., Duliu O.G., Fattibene P., Haskell E.H., Hayes R.B., Ignatiev E.A., Ivannikov A., Kirillov V., Kleschenko E., Nakamura N., Nather M., Nowak J., Onori S., Pass B., Pivovarov S., Romanyukha A., Scherbina O., Shames A.I., Sholom S., Skvortsov V., Stepanenko V., Tikounov D.D., and Toyoda S. The second international intercomparison on EPR tooth dosimetry. Radiat. Meas. 32 (2000) 549-557
-
(2000)
Radiat. Meas.
, vol.32
, pp. 549-557
-
-
Wieser, A.1
Mehta, K.2
Amira, S.3
Aragno, D.4
Bercea, S.5
Brik, A.6
Bugai, A.7
Callens, F.8
Chumak, V.9
Ciesielski, B.10
Debuyst, R.11
Dubovsky, S.12
Duliu, O.G.13
Fattibene, P.14
Haskell, E.H.15
Hayes, R.B.16
Ignatiev, E.A.17
Ivannikov, A.18
Kirillov, V.19
Kleschenko, E.20
Nakamura, N.21
Nather, M.22
Nowak, J.23
Onori, S.24
Pass, B.25
Pivovarov, S.26
Romanyukha, A.27
Scherbina, O.28
Shames, A.I.29
Sholom, S.30
Skvortsov, V.31
Stepanenko, V.32
Tikounov, D.D.33
Toyoda, S.34
more..
-
5
-
-
0035126470
-
Dependencies of the radiation sensitivity of human tooth enamel in EPR dosimetry
-
Wieser A., El-Faramvy N., and Meckbach R. Dependencies of the radiation sensitivity of human tooth enamel in EPR dosimetry. Appl. Radiat. Isot. 54 (2001) 793-799
-
(2001)
Appl. Radiat. Isot.
, vol.54
, pp. 793-799
-
-
Wieser, A.1
El-Faramvy, N.2
Meckbach, R.3
-
6
-
-
33749830987
-
The third international intercomparison on EPR tooth dosimetry: part 2: final analysis
-
Wieser A., et al. The third international intercomparison on EPR tooth dosimetry: part 2: final analysis. Radiat. Prot. Dosim. 120 (2006) 176-183
-
(2006)
Radiat. Prot. Dosim.
, vol.120
, pp. 176-183
-
-
Wieser, A.1
-
7
-
-
46549089691
-
-
Wieser, A., et al., Assessment of perforamnce parameters for EPR dosimetry with tooth enamel. Radiat. Meas., 2008, doi:10.1016/j.radmeas.2008.01.032.
-
Wieser, A., et al., Assessment of perforamnce parameters for EPR dosimetry with tooth enamel. Radiat. Meas., 2008, doi:10.1016/j.radmeas.2008.01.032.
-
-
-
-
8
-
-
0038141978
-
An in vitro L-band EPR study with whole human teeth in a surface coil resonator
-
Zdravkova M., Wieser A., El-Faramawy N., Ivanov D., Galleza B., and Debuysta R. An in vitro L-band EPR study with whole human teeth in a surface coil resonator. Radiat. Meas. 37 (2003) 347-353
-
(2003)
Radiat. Meas.
, vol.37
, pp. 347-353
-
-
Zdravkova, M.1
Wieser, A.2
El-Faramawy, N.3
Ivanov, D.4
Galleza, B.5
Debuysta, R.6
-
9
-
-
0642272950
-
Weighted least-square approach to calculating limits of detection and quantification by modeling variability as a function of concentration
-
Zorn M.E., Gibbons R.D., and Sonzogni W.C. Weighted least-square approach to calculating limits of detection and quantification by modeling variability as a function of concentration. Anal. Chem. 69 (1997) 3069-3075
-
(1997)
Anal. Chem.
, vol.69
, pp. 3069-3075
-
-
Zorn, M.E.1
Gibbons, R.D.2
Sonzogni, W.C.3
|