메뉴 건너뛰기




Volumn 43, Issue 2-6, 2008, Pages 827-830

Analysis of sources of uncertainty of tooth enamel EPR signal amplitude

Author keywords

Dosimetry; EPR; Tooth enamel

Indexed keywords

DISINFECTION; DOSIMETRY; GRAIN SIZE AND SHAPE; SAMPLING; UNCERTAINTY ANALYSIS;

EID: 46549083808     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.11.063     Document Type: Article
Times cited : (9)

References (8)
  • 1
    • 10644297061 scopus 로고    scopus 로고
    • EPR tooth dosimetry as a tool for validation of retrospective doses: an end-user perspective
    • Bhat M. EPR tooth dosimetry as a tool for validation of retrospective doses: an end-user perspective. Appl. Radiat. Isot. 62 (2005) 155-161
    • (2005) Appl. Radiat. Isot. , vol.62 , pp. 155-161
    • Bhat, M.1
  • 2
    • 46549089531 scopus 로고    scopus 로고
    • CDC, Centers for Disease Control and Prevention, 1993. Recommended infection-control practices for dentistry. MMWR Recommendations and Reports, vol. 42, No. RR08;001 05/28/1993 Atlanta.
    • CDC, Centers for Disease Control and Prevention, 1993. Recommended infection-control practices for dentistry. MMWR Recommendations and Reports, vol. 42, No. RR08;001 05/28/1993 Atlanta.
  • 3
    • 46549086115 scopus 로고    scopus 로고
    • IAEA, 2002. Use of the electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. IAEA-TECDOC-1331, International Atomic Energy Agency, Vienna, Austria, 57pp.
    • IAEA, 2002. Use of the electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. IAEA-TECDOC-1331, International Atomic Energy Agency, Vienna, Austria, 57pp.
  • 4
    • 46549089446 scopus 로고    scopus 로고
    • ISO, 1995. Guide to the Expression of Uncertainty in Measurement, 1993 (corrected and reprinted 1995).
    • ISO, 1995. Guide to the Expression of Uncertainty in Measurement, 1993 (corrected and reprinted 1995).
  • 6
    • 0034308239 scopus 로고    scopus 로고
    • Advancements in accuracy of the alanine dosimetry system. Part 3. Usefulness of an adjacent reference sample
    • Nagy V., Sleptchonok O.F., Desrosiers M.F., Weber R.T., and Heiss A.H. Advancements in accuracy of the alanine dosimetry system. Part 3. Usefulness of an adjacent reference sample. Radiat. Phys. Chem. 57 (2000) 429-441
    • (2000) Radiat. Phys. Chem. , vol.57 , pp. 429-441
    • Nagy, V.1    Sleptchonok, O.F.2    Desrosiers, M.F.3    Weber, R.T.4    Heiss, A.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.