-
5
-
-
4544366331
-
Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
-
Bakker E., Buhlmann P., and Pretsch E. Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics. Chem. Rev. 97 (1997) 3083-3132
-
(1997)
Chem. Rev.
, vol.97
, pp. 3083-3132
-
-
Bakker, E.1
Buhlmann, P.2
Pretsch, E.3
-
6
-
-
0032099044
-
Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
-
Buhlmann P., Pretsch E., and Bakker E. Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 98 (1998) 1593-1687
-
(1998)
Chem. Rev.
, vol.98
, pp. 1593-1687
-
-
Buhlmann, P.1
Pretsch, E.2
Bakker, E.3
-
7
-
-
13944269075
-
Potentiometric sensors for trace-level analysis
-
Bakker E., and Pretsch E. Potentiometric sensors for trace-level analysis. Trend Anal. Chem. 24 No. 3 (2005) 199-207
-
(2005)
Trend Anal. Chem.
, vol.24
, Issue.3
, pp. 199-207
-
-
Bakker, E.1
Pretsch, E.2
-
8
-
-
33846314730
-
Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level
-
Rubinova N., Chumbimuni-Torres K., and Bakker E. Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level. Sens. Actuators B: Chem. 121 (2007) 135-141
-
(2007)
Sens. Actuators B: Chem.
, vol.121
, pp. 135-141
-
-
Rubinova, N.1
Chumbimuni-Torres, K.2
Bakker, E.3
-
9
-
-
33745644002
-
Novel potentiometric and optical silver ion-selective sensors with subnanomolar detection limits
-
Szigeti Z., Malon A., Vigassy T., Csokai V., Grün A., Wygladacz K., Ye N., Xu C., Chebny V.J., Bitter I., Rathore R., Bakker E., and Pretsch E. Novel potentiometric and optical silver ion-selective sensors with subnanomolar detection limits. Anal. Chim. Acta 572 (2006) 1-10
-
(2006)
Anal. Chim. Acta
, vol.572
, pp. 1-10
-
-
Szigeti, Z.1
Malon, A.2
Vigassy, T.3
Csokai, V.4
Grün, A.5
Wygladacz, K.6
Ye, N.7
Xu, C.8
Chebny, V.J.9
Bitter, I.10
Rathore, R.11
Bakker, E.12
Pretsch, E.13
-
11
-
-
1542444385
-
Alumina and support-coated open-tubular columns in open-tubular micro-capillary liquid chromatography
-
Hibi K., Ishii D., and Tsuda T. Alumina and support-coated open-tubular columns in open-tubular micro-capillary liquid chromatography. J. Chromatogr. A 189 (1980) 179-185
-
(1980)
J. Chromatogr. A
, vol.189
, pp. 179-185
-
-
Hibi, K.1
Ishii, D.2
Tsuda, T.3
-
12
-
-
0023120814
-
Potentiometric detector for fast high-performance open-tubular column liquid chromatography
-
Manz A., and Simon W. Potentiometric detector for fast high-performance open-tubular column liquid chromatography. Anal. Chem. 59 (1987) 74-79
-
(1987)
Anal. Chem.
, vol.59
, pp. 74-79
-
-
Manz, A.1
Simon, W.2
-
15
-
-
0007308590
-
Potentiometric detection of halides and pseudohalides in anion chromatography
-
Lockridge J.E., Fortier N.E., Schmuckler G., and Fritz J.S. Potentiometric detection of halides and pseudohalides in anion chromatography. Anal. Chim. Acta 192 (1987) 41-48
-
(1987)
Anal. Chim. Acta
, vol.192
, pp. 41-48
-
-
Lockridge, J.E.1
Fortier, N.E.2
Schmuckler, G.3
Fritz, J.S.4
-
16
-
-
0000208606
-
Direct and replacement ion chromatography with potentiometric detection using a silver/silver bromide electrode
-
Trojanowicz M., Pobozy E., and Meyerhoff M.E. Direct and replacement ion chromatography with potentiometric detection using a silver/silver bromide electrode. Anal. Chim. Acta 222 (1989) 109-119
-
(1989)
Anal. Chim. Acta
, vol.222
, pp. 109-119
-
-
Trojanowicz, M.1
Pobozy, E.2
Meyerhoff, M.E.3
-
17
-
-
0001188022
-
Potentiometric pH detection in suppressed ion chromatography
-
Trojanowicz M., and Meyerhoff M.E. Potentiometric pH detection in suppressed ion chromatography. Anal. Chem. 61 (1989) 787-789
-
(1989)
Anal. Chem.
, vol.61
, pp. 787-789
-
-
Trojanowicz, M.1
Meyerhoff, M.E.2
-
18
-
-
0007298776
-
Replacement ion chromatography with potentiometric detection using a potassium-selective membrane electrode
-
Trojanowicz M., and Meyerhoff M.E. Replacement ion chromatography with potentiometric detection using a potassium-selective membrane electrode. Anal. Chim. Acta 222 (1989) 95-107
-
(1989)
Anal. Chim. Acta
, vol.222
, pp. 95-107
-
-
Trojanowicz, M.1
Meyerhoff, M.E.2
-
19
-
-
0031828927
-
Potentiometric detection of organic acids in liquid chromatography using conducting oligomer electrodes
-
Poels I., Nagels L.J., Verreyt G., and Geise H.J. Potentiometric detection of organic acids in liquid chromatography using conducting oligomer electrodes. Anal. Chim. Acta 370 (1998) 105-113
-
(1998)
Anal. Chim. Acta
, vol.370
, pp. 105-113
-
-
Poels, I.1
Nagels, L.J.2
Verreyt, G.3
Geise, H.J.4
-
20
-
-
0032978906
-
Simultaneous detection of monovalent anions and cations using all solid-state contact PVC membrane anion and cation-selective electrodes as detectors in single column ion chromatography
-
Isi{dotless}ldak I., and Asan A. Simultaneous detection of monovalent anions and cations using all solid-state contact PVC membrane anion and cation-selective electrodes as detectors in single column ion chromatography. Talanta 48 (1999) 967-978
-
(1999)
Talanta
, vol.48
, pp. 967-978
-
-
Isildak, I.1
Asan, A.2
-
21
-
-
0032999633
-
In situ preparation of a cholesterol biosensor: entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system: determination of total cholesterol in serum
-
Vidal J.C., Garcia E., and Castillo J.R. In situ preparation of a cholesterol biosensor: entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system: determination of total cholesterol in serum. Anal. Chim. Acta 385 (1999) 213-222
-
(1999)
Anal. Chim. Acta
, vol.385
, pp. 213-222
-
-
Vidal, J.C.1
Garcia, E.2
Castillo, J.R.3
-
22
-
-
0000945140
-
Incorporation of erythrocytes into polypyrrole to form the basis of a biosensor to screen for rhesus (D) blood groups and rhesus (D) antibodies
-
Campbell T.E., Hodgson A.J., and Wallace G.G. Incorporation of erythrocytes into polypyrrole to form the basis of a biosensor to screen for rhesus (D) blood groups and rhesus (D) antibodies. Electroanalysis 11 (1999) 215-222
-
(1999)
Electroanalysis
, vol.11
, pp. 215-222
-
-
Campbell, T.E.1
Hodgson, A.J.2
Wallace, G.G.3
-
23
-
-
0031698047
-
Conductivity switching in polypyrrole-coated textile fabrics as gas sensors
-
Kincal D., Kamer A., Child A.D., and Reynold J.R. Conductivity switching in polypyrrole-coated textile fabrics as gas sensors. Synth. Met. 92 (1998) 53-56
-
(1998)
Synth. Met.
, vol.92
, pp. 53-56
-
-
Kincal, D.1
Kamer, A.2
Child, A.D.3
Reynold, J.R.4
-
24
-
-
0032597122
-
Temperature-dependent conductivity of conducting polymers exposed to gases
-
Kemp N.T., Flanagan G.U., Kaiser A.B., Trodahl H.J., Chapman B., Partridge A.C., and Buckley R.G. Temperature-dependent conductivity of conducting polymers exposed to gases. Synth. Met. 101 (1999) 434-435
-
(1999)
Synth. Met.
, vol.101
, pp. 434-435
-
-
Kemp, N.T.1
Flanagan, G.U.2
Kaiser, A.B.3
Trodahl, H.J.4
Chapman, B.5
Partridge, A.C.6
Buckley, R.G.7
-
25
-
-
0026424540
-
Effect of electrode substrate on the morphology and selectivity of overoxidized polypyrrole films
-
Witkowsky A., Freund M.S., and Brajter-Toth A. Effect of electrode substrate on the morphology and selectivity of overoxidized polypyrrole films. Anal. Chem. 63 (1991) 622-626
-
(1991)
Anal. Chem.
, vol.63
, pp. 622-626
-
-
Witkowsky, A.1
Freund, M.S.2
Brajter-Toth, A.3
-
26
-
-
0030296784
-
Permselectivity of neurotransmitters at overoxidized polypyrrole-film-coated glassy carbon electrodes
-
Kang T.-F., Shen G.-L., and Yu R.-Q. Permselectivity of neurotransmitters at overoxidized polypyrrole-film-coated glassy carbon electrodes. Talanta 43 (1996) 2007-2013
-
(1996)
Talanta
, vol.43
, pp. 2007-2013
-
-
Kang, T.-F.1
Shen, G.-L.2
Yu, R.-Q.3
-
27
-
-
0346629959
-
Electrochemical preparation and analytical applications of ultrathin overoxidized polypyrrole films
-
Hsueh C., and Brajter-Toth A. Electrochemical preparation and analytical applications of ultrathin overoxidized polypyrrole films. Anal. Chem. 66 (1994) 2458-2464
-
(1994)
Anal. Chem.
, vol.66
, pp. 2458-2464
-
-
Hsueh, C.1
Brajter-Toth, A.2
-
29
-
-
18744433493
-
Preparation of sulfonated overoxidized polypyrrole film applicable as an SPME tool for cationic analytes
-
Tamer U., Şahin Y., Ertaş N., Udum Y.A., Pekmez K., and Yi{dotless}ldi{dotless}z A. Preparation of sulfonated overoxidized polypyrrole film applicable as an SPME tool for cationic analytes. J. Electroanal. Chem. 570 (2004) 6-12
-
(2004)
J. Electroanal. Chem.
, vol.570
, pp. 6-12
-
-
Tamer, U.1
Şahin, Y.2
Ertaş, N.3
Udum, Y.A.4
Pekmez, K.5
Yildiz, A.6
-
30
-
-
21344437336
-
Electrochemically controlled solid-phase microextraction (EC-SPME) based on overoxidized sulfonated polypyrrole
-
Tamer U., Ertaş N., Udum Y., Şahin Y., Pekmez K., and Yi{dotless}ldi{dotless}z A. Electrochemically controlled solid-phase microextraction (EC-SPME) based on overoxidized sulfonated polypyrrole. Talanta 67 (2005) 245-251
-
(2005)
Talanta
, vol.67
, pp. 245-251
-
-
Tamer, U.1
Ertaş, N.2
Udum, Y.3
Şahin, Y.4
Pekmez, K.5
Yildiz, A.6
-
31
-
-
46449115665
-
-
Y. Şahin, B. Ercan, M. Şahin, Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode, J. Appl. Polym. Sci., in press.
-
Y. Şahin, B. Ercan, M. Şahin, Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode, J. Appl. Polym. Sci., in press.
-
-
-
-
32
-
-
40849134182
-
In situ electrochemical solid-phase extraction of anions and cations using polypyrrole and overoxidized sulfonated polypyrrole
-
Şahin Y., Ercan B., and Şahin M. In situ electrochemical solid-phase extraction of anions and cations using polypyrrole and overoxidized sulfonated polypyrrole. Talanta 75 (2008) 369-375
-
(2008)
Talanta
, vol.75
, pp. 369-375
-
-
Şahin, Y.1
Ercan, B.2
Şahin, M.3
-
33
-
-
0030794669
-
How to understand the response mechanism of ion-selective electrodes
-
Pungor E. How to understand the response mechanism of ion-selective electrodes. Talanta 44 (1997) 1505-1508
-
(1997)
Talanta
, vol.44
, pp. 1505-1508
-
-
Pungor, E.1
-
35
-
-
33646931832
-
Analyte-stationary phase interactions in ion-exlusion chromatography
-
Novic M., and Haddad P.R. Analyte-stationary phase interactions in ion-exlusion chromatography. J. Chromatogr. A 1118 (2006) 19-28
-
(2006)
J. Chromatogr. A
, vol.1118
, pp. 19-28
-
-
Novic, M.1
Haddad, P.R.2
-
36
-
-
0016774082
-
Differential pulse polarographic determination of some carcinogenic nitrosamines
-
Hasebe K., and Osteryong J. Differential pulse polarographic determination of some carcinogenic nitrosamines. Anal. Chem. 47 (1975) 2412-2418
-
(1975)
Anal. Chem.
, vol.47
, pp. 2412-2418
-
-
Hasebe, K.1
Osteryong, J.2
-
37
-
-
0034027825
-
Solid phase microextraction of inorganic ions based on polypyrrole film
-
Wu J., Yu X., Lord H., and Pawliszyn J. Solid phase microextraction of inorganic ions based on polypyrrole film. Analyst 125 (2000) 391-394
-
(2000)
Analyst
, vol.125
, pp. 391-394
-
-
Wu, J.1
Yu, X.2
Lord, H.3
Pawliszyn, J.4
|