메뉴 건너뛰기




Volumn 133, Issue 1, 2008, Pages 241-243

Selective and enhanced nitric oxide detection using hemoprotein/silica hybrids

Author keywords

Biosensor; Guanylyl cyclase; Hemoprotein; Mesoporous silica; Nitric oxide; QCM

Indexed keywords

ALUMINUM; BIOELECTRIC PHENOMENA; CHEMICAL SENSORS; COLLOIDS; ETHYLENE GLYCOL; GELATION; GLYCOLS; IRON; METALLIZING; NITRIC OXIDE; NITROGEN; NITROGEN OXIDES; OXIDE MINERALS; PHOTORESISTS; PHYSISORPTION; POLYETHYLENE GLYCOLS; POLYETHYLENES; PORPHYRINS; QUARTZ; QUARTZ CRYSTAL MICROBALANCES; SILICA; SILICATE MINERALS; SILICON COMPOUNDS; SOL-GEL PROCESS;

EID: 46449113217     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2008.02.016     Document Type: Article
Times cited : (11)

References (16)
  • 1
    • 1942536520 scopus 로고    scopus 로고
    • Quartz crystal microbalance coated with sol-gel-derived indium-tin oxide thin films as gas sensor for NO detection
    • Zhang J., Hu J., Zhu Z.Q., Gong H., and O'Shea S.J. Quartz crystal microbalance coated with sol-gel-derived indium-tin oxide thin films as gas sensor for NO detection. Colloids Surf. A: Physicochem. Eng. Aspects 236 (2004) 23-30
    • (2004) Colloids Surf. A: Physicochem. Eng. Aspects , vol.236 , pp. 23-30
    • Zhang, J.1    Hu, J.2    Zhu, Z.Q.3    Gong, H.4    O'Shea, S.J.5
  • 2
    • 8844259723 scopus 로고    scopus 로고
    • Amperometric determination of nitric oxide derived from pulmonary artery endothelial cells immobilized in a microchip channel
    • Spence D.M., Torrence N.J., Kovarik M.L., and Martin R.S. Amperometric determination of nitric oxide derived from pulmonary artery endothelial cells immobilized in a microchip channel. Analyst 129 (2004) 995-1000
    • (2004) Analyst , vol.129 , pp. 995-1000
    • Spence, D.M.1    Torrence, N.J.2    Kovarik, M.L.3    Martin, R.S.4
  • 3
    • 19744367343 scopus 로고    scopus 로고
    • Bulk acoustic wave resonator as a sensing platform for NOx at high temperatures
    • Seh H., Hyodo T., and Tuller H.L. Bulk acoustic wave resonator as a sensing platform for NOx at high temperatures. Sens. Actuators B 108 (2005) 547-552
    • (2005) Sens. Actuators B , vol.108 , pp. 547-552
    • Seh, H.1    Hyodo, T.2    Tuller, H.L.3
  • 4
    • 20944432938 scopus 로고    scopus 로고
    • Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications
    • Hemmingsson T., Linnarsson D., and Gambert R. Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications. J. Clin. Monit. Comput. 18 (2004) 379-387
    • (2004) J. Clin. Monit. Comput. , vol.18 , pp. 379-387
    • Hemmingsson, T.1    Linnarsson, D.2    Gambert, R.3
  • 5
    • 25144505892 scopus 로고    scopus 로고
    • Integrated cavity output spectroscopy measurements of nitric oxide levels in breath with a pulsed room-temperature quantum cascade laser
    • Silva M.L., Sonnenfroh D.M., Rosen D.I., Allen M.G., and O'keefe A. Integrated cavity output spectroscopy measurements of nitric oxide levels in breath with a pulsed room-temperature quantum cascade laser. Appl. Phys. B 81 (2005) 705-710
    • (2005) Appl. Phys. B , vol.81 , pp. 705-710
    • Silva, M.L.1    Sonnenfroh, D.M.2    Rosen, D.I.3    Allen, M.G.4    O'keefe, A.5
  • 6
    • 2342584132 scopus 로고    scopus 로고
    • Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
    • Bakhirkin Y.A., Kosterev A.A., Roller C., Curl R.F., and Tittel F.K. Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection. Appl. Opt. 43 (2004) 2257-2266
    • (2004) Appl. Opt. , vol.43 , pp. 2257-2266
    • Bakhirkin, Y.A.1    Kosterev, A.A.2    Roller, C.3    Curl, R.F.4    Tittel, F.K.5
  • 8
    • 33845656912 scopus 로고    scopus 로고
    • Four-channel QCA using mesoporous silica films for gas sensing applications
    • Palaniappan Al., Su X.D., and Tay F.E.H. Four-channel QCA using mesoporous silica films for gas sensing applications. IEEE Sens. J. 6 (2006) 1676-1682
    • (2006) IEEE Sens. J. , vol.6 , pp. 1676-1682
    • Palaniappan, Al.1    Su, X.D.2    Tay, F.E.H.3
  • 9
    • 16244376841 scopus 로고    scopus 로고
    • Ligand specificity of H-NOX domains: from sGC to bacterial NO sensors
    • Boon E.M., and Marletta M.A. Ligand specificity of H-NOX domains: from sGC to bacterial NO sensors. J. Inorg. Biochem. 99 (2005) 892-902
    • (2005) J. Inorg. Biochem. , vol.99 , pp. 892-902
    • Boon, E.M.1    Marletta, M.A.2
  • 10
    • 0033120934 scopus 로고    scopus 로고
    • Heme-based sensors in biological systems
    • Rodgers K.R. Heme-based sensors in biological systems. Bio-inorg. Chem. 3 (1999) 158-167
    • (1999) Bio-inorg. Chem. , vol.3 , pp. 158-167
    • Rodgers, K.R.1
  • 11
    • 0037125991 scopus 로고    scopus 로고
    • Revisiting the kinetics of nitric oxide (NO) binding to soluble guanylate cyclase: the simple NO-binding model is incorrect
    • Ballou D.P., Zhao Y., Brandish P.E., and Marletta M.A. Revisiting the kinetics of nitric oxide (NO) binding to soluble guanylate cyclase: the simple NO-binding model is incorrect. PNAS 99 (2002) 12097-12101
    • (2002) PNAS , vol.99 , pp. 12097-12101
    • Ballou, D.P.1    Zhao, Y.2    Brandish, P.E.3    Marletta, M.A.4
  • 12
    • 33746817879 scopus 로고    scopus 로고
    • Specific detection of gaseous NO and 15NO in the headspace from liquid-phase reactions involving NO-generating organic, inorganic, and biochemical samples using a mid-infrared laser
    • Yi J., Namjou K., Zahran Z.N., McCann P.J., and Richter-Addo G.B. Specific detection of gaseous NO and 15NO in the headspace from liquid-phase reactions involving NO-generating organic, inorganic, and biochemical samples using a mid-infrared laser. Nitric Oxide 15 (2006) 154-162
    • (2006) Nitric Oxide , vol.15 , pp. 154-162
    • Yi, J.1    Namjou, K.2    Zahran, Z.N.3    McCann, P.J.4    Richter-Addo, G.B.5
  • 14
    • 0037099288 scopus 로고    scopus 로고
    • Simultaneous quartz crystal microbalance impedance and electrochemical impedance measurements. Investigation into the degradation of thin polymer films
    • Andrea S., and Steffi K. Simultaneous quartz crystal microbalance impedance and electrochemical impedance measurements. Investigation into the degradation of thin polymer films. Anal. Chem. 74 (2002) 3304-3311
    • (2002) Anal. Chem. , vol.74 , pp. 3304-3311
    • Andrea, S.1    Steffi, K.2
  • 15
    • 11744318388 scopus 로고
    • Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance
    • Buttry D.A., and Ward M.D. Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance. Chem. Rev. 92 (1992) 1355-1379
    • (1992) Chem. Rev. , vol.92 , pp. 1355-1379
    • Buttry, D.A.1    Ward, M.D.2
  • 16
    • 0028228808 scopus 로고
    • Soluble guanylate cyclase from bovine lung: activation with nitric oxide and carbon monoxide and spectral characterization of the ferrous and ferric States
    • Stone J.R., and Marletta M.A. Soluble guanylate cyclase from bovine lung: activation with nitric oxide and carbon monoxide and spectral characterization of the ferrous and ferric States. Biochemistry 33 (1994) 5636-5640
    • (1994) Biochemistry , vol.33 , pp. 5636-5640
    • Stone, J.R.1    Marletta, M.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.