메뉴 건너뛰기




Volumn 26, Issue 6, 2008, Pages 860-864

Accuracy of navigated surgery of the pelvis after surface matching with an a-mode ultrasound probe

Author keywords

A mode ultrasound; Computer assisted surgery; Navigation; Pelvis; Surface matching

Indexed keywords

ACCURACY; ANIMAL TISSUE; ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FLUOROSCOPY; IMAGE QUALITY; MUSCLE TISSUE; NONHUMAN; PELVIS SURGERY; PRIORITY JOURNAL; ULTRASOUND; ANIMAL; AUDIOVISUAL EQUIPMENT; ECHOGRAPHY; HUMAN; INSTRUMENTATION; PATIENT MONITORING; PELVIS; RADIOGRAPHY; REPRODUCIBILITY; SKELETAL MUSCLE; STANDARD; SWINE; VALIDATION STUDY;

EID: 46449100471     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1002/jor.20551     Document Type: Article
Times cited : (20)

References (15)
  • 1
    • 0036943345 scopus 로고    scopus 로고
    • Computer assisted pelvic and acetabular surgery. Clinical experiences and indications
    • Stockle U, Konig B, Dahne M, et al. 2002. Computer assisted pelvic and acetabular surgery. Clinical experiences and indications. Unfallchirurg 105:886-892.
    • (2002) Unfallchirurg , vol.105 , pp. 886-892
    • Stockle, U.1    Konig, B.2    Dahne, M.3
  • 2
    • 33748992902 scopus 로고    scopus 로고
    • Simultaneous registration with ct-fluoro matching for spinal navigation surgery. A case report
    • Sakai Y, Matsuyama Y, Yoshihara H, et al. 2006. Simultaneous registration with ct-fluoro matching for spinal navigation surgery. A case report. Nagoya J Med Sci 68:45-52.
    • (2006) Nagoya J Med Sci , vol.68 , pp. 45-52
    • Sakai, Y.1    Matsuyama, Y.2    Yoshihara, H.3
  • 3
    • 0002375331 scopus 로고    scopus 로고
    • Registration for computer-integrated surgery, methodology, state of the art
    • Taylor R, Lavallee S, Burdea G, Mösges R, editors, London: MIT Press; p
    • Lavallee S. 1996. Registration for computer-integrated surgery, methodology, state of the art. In: Taylor R, Lavallee S, Burdea G, Mösges R, editors. Computer integrated surgery. London: MIT Press; p 77-97.
    • (1996) Computer integrated surgery , pp. 77-97
    • Lavallee, S.1
  • 4
    • 52449117645 scopus 로고    scopus 로고
    • Entwicklung und Einführung der Computerassistierten Navigation in der Wirbelsäulenchirurgie unter besonderer Berücksichtigung der Pedikelschraubeninsertion
    • Hannover: Medizinische Hochschule Hannover; p
    • Berlemann U. 2002. Entwicklung und Einführung der Computerassistierten Navigation in der Wirbelsäulenchirurgie unter besonderer Berücksichtigung der Pedikelschraubeninsertion. In: Unfallchirurgische Klinik. Hannover: Medizinische Hochschule Hannover; p 93.
    • (2002) Unfallchirurgische Klinik , pp. 93
    • Berlemann, U.1
  • 5
    • 33750088518 scopus 로고    scopus 로고
    • Computerassistierte Beckenchirurgie -Präzisionsanalyse, Innovationen und klinische Anwendungen
    • Hannover: Medizinische Hochschule Hannover; p
    • Hüfner T. 2001. Computerassistierte Beckenchirurgie -Präzisionsanalyse, Innovationen und klinische Anwendungen. In: Unfallchirurgische Klinik. Hannover: Medizinische Hochschule Hannover; p 145.
    • (2001) Unfallchirurgische Klinik , pp. 145
    • Hüfner, T.1
  • 6
    • 0036913705 scopus 로고    scopus 로고
    • Computer-assisted pelvic surgery: An in vitro study of two registration protocols
    • Van Hellemondt G, De Kleuver M, Kerckhaert A, et al. 2002. Computer-assisted pelvic surgery: an in vitro study of two registration protocols. Clin Orthop 405:287-293.
    • (2002) Clin Orthop , vol.405 , pp. 287-293
    • Van Hellemondt, G.1    De Kleuver, M.2    Kerckhaert, A.3
  • 7
    • 0346220302 scopus 로고    scopus 로고
    • A-mode ultrasound-based registration in computer-aided surgery of the skull
    • Amstutz C, et al. 2003. A-mode ultrasound-based registration in computer-aided surgery of the skull. Arch Otolaryngol Head Neck Surg 129:1310-1316.
    • (2003) Arch Otolaryngol Head Neck Surg , vol.129 , pp. 1310-1316
    • Amstutz, C.1
  • 8
    • 0036357882 scopus 로고    scopus 로고
    • Visual user guidance for registration based on A-mode ultrasound
    • Heger S, Portheine F, Ohnsorge J, et al. 2002. Visual user guidance for registration based on A-mode ultrasound. Biomed Tech (Berl) 47(Suppl 1):61-64.
    • (2002) Biomed Tech (Berl) , vol.47 , Issue.SUPPL. 1 , pp. 61-64
    • Heger, S.1    Portheine, F.2    Ohnsorge, J.3
  • 9
    • 17644415674 scopus 로고    scopus 로고
    • User-interactive registration of bone with A-mode ultrasound
    • Heger S, Portheine F, Ohnsorge JA, et al. 2005. User-interactive registration of bone with A-mode ultrasound. IEEE Eng Med Biol Mag 24:85-95.
    • (2005) IEEE Eng Med Biol Mag , vol.24 , pp. 85-95
    • Heger, S.1    Portheine, F.2    Ohnsorge, J.A.3
  • 10
    • 0041398146 scopus 로고    scopus 로고
    • Ultrasound-based registriation of the pelvic bone surface for surgical navigation
    • Amin DV, Kanade T, Di Gioia AM, et al. 2001. Ultrasound-based registriation of the pelvic bone surface for surgical navigation. Comput Aided Surg 6:48.
    • (2001) Comput Aided Surg , vol.6 , pp. 48
    • Amin, D.V.1    Kanade, T.2    Di Gioia, A.M.3
  • 11
    • 0035201925 scopus 로고    scopus 로고
    • Accuracy evaluation of a CAS system: A laboratory protocol and results with 6D localizers, and clinical experiences in otorhinolaryngology
    • Schmerber S, Chassat F. 2001. Accuracy evaluation of a CAS system: a laboratory protocol and results with 6D localizers, and clinical experiences in otorhinolaryngology. Comput Aided Surg 6:1-13.
    • (2001) Comput Aided Surg , vol.6 , pp. 1-13
    • Schmerber, S.1    Chassat, F.2
  • 12
    • 0006838586 scopus 로고    scopus 로고
    • Oberflächenbasierte Registrierung für orthopädische und HNO-Anwendungen
    • Bern: Universitä Bern; p
    • Baechler R. 2000. Oberflächenbasierte Registrierung für orthopädische und HNO-Anwendungen. In: Philosophisch-Naturwissenschaftliche Fakultät. Bern: Universitä Bern; p 114.
    • (2000) Philosophisch-Naturwissenschaftliche Fakultät , pp. 114
    • Baechler, R.1
  • 13
    • 0035197536 scopus 로고    scopus 로고
    • Restricted surface matching-numerical optimization and technical evaluation
    • Baechler R, Bunke H, Nolte LP. 2001. Restricted surface matching-numerical optimization and technical evaluation. Comput Aided Surg 6:143-152.
    • (2001) Comput Aided Surg , vol.6 , pp. 143-152
    • Baechler, R.1    Bunke, H.2    Nolte, L.P.3
  • 14
    • 0036449407 scopus 로고    scopus 로고
    • Comparative in vitro study of contact- and image-based rigid registration for computer-aided surgery
    • Sadowsky O, Yaniv Z, Joskowicz L. 2002. Comparative in vitro study of contact- and image-based rigid registration for computer-aided surgery. Comput Aided Surg 7:223-236.
    • (2002) Comput Aided Surg , vol.7 , pp. 223-236
    • Sadowsky, O.1    Yaniv, Z.2    Joskowicz, L.3
  • 15
    • 0035708295 scopus 로고    scopus 로고
    • Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach
    • Sugano N, Sasama T, Sato Y, et al. 2001. Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg 6:195-203.
    • (2001) Comput Aided Surg , vol.6 , pp. 195-203
    • Sugano, N.1    Sasama, T.2    Sato, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.