메뉴 건너뛰기




Volumn , Issue , 2007, Pages 613-618

Sensitivity and variance analysis of arterial pressure transfer dynamics estimated from adaptive multi-channel system identification

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURES; ASYMPTOTIC VARIANCE; BLOOD PRESSURE WAVEFORM; DATA LENGTHS; EIGEN-STRUCTURE; HIGH-FREQUENCY (HF); IDENTIFIABILITY; MULTI CHANNEL (MC); PARAMETRIC SENSITIVITY; PHYSIOLOGIC CONDITIONS; PRESSURE TRANSFER; SENSITIVITY MATRICES; SYSTEM IDENTIFICATION (SI); TRANSMISSION TIME; VARIANCE ANALYSIS;

EID: 46449085612     PISSN: 07431619     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ACC.2007.4282662     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 34047213234 scopus 로고    scopus 로고
    • A blind approach to reconstruction of aortic blood pressure waveform using gray-box identification of multiple pressure transfer channels
    • Minneapolis, USA
    • J.O. Hahn, A.T. Reisner, and H.H. Asada, "A blind approach to reconstruction of aortic blood pressure waveform using gray-box identification of multiple pressure transfer channels," in Proc. '2006 American Control Conference, Minneapolis, USA, 2006.
    • (2006) Proc. '2006 American Control Conference
    • Hahn, J.O.1    Reisner, A.T.2    Asada, H.H.3
  • 3
    • 0032984064 scopus 로고    scopus 로고
    • Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry
    • B. Fetics, E. Nevo, C.-H. Chen, and D.A. Kass, "Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry," IEEE Transactions on Biomedical Engineering, vol. 46, pp. 698-706, 1999.
    • (1999) IEEE Transactions on Biomedical Engineering , vol.46 , pp. 698-706
    • Fetics, B.1    Nevo, E.2    Chen, C.-H.3    Kass, D.A.4
  • 4
    • 0022976166 scopus 로고
    • Estimation of total arterial compliance: An improved method and evaluation of current methods
    • Z. Liu, K.P. Brin, and F.C. Yin, "Estimation of total arterial compliance: an improved method and evaluation of current methods," American Journal of Physiology, vol. 251, pp. 588-600, 1986.
    • (1986) American Journal of Physiology , vol.251 , pp. 588-600
    • Liu, Z.1    Brin, K.P.2    Yin, F.C.3
  • 5
    • 0141861625 scopus 로고    scopus 로고
    • Philadelphia, PA: Saunders
    • L.S. Costanzo, Physiology. Philadelphia, PA: Saunders, 2002.
    • (2002) Physiology
    • Costanzo, L.S.1
  • 6
    • 0041592764 scopus 로고    scopus 로고
    • Use of arterial transfer functions for the derivation of aortic waveform characteristics
    • S.A. Hope, D.B. Tay, I.T. Meredith, and J.D. Cameron, "Use of arterial transfer functions for the derivation of aortic waveform characteristics," Journal of Hypertension, vol. 21, pp. 1299-1305, 2003.
    • (2003) Journal of Hypertension , vol.21 , pp. 1299-1305
    • Hope, S.A.1    Tay, D.B.2    Meredith, I.T.3    Cameron, J.D.4
  • 7
    • 7944232464 scopus 로고    scopus 로고
    • Validation of the transfer function technique for generating central from peripheral upper limg pressure waveform
    • D. Gallagher, A. Adji, and M.F. O'Rourke, "Validation of the transfer function technique for generating central from peripheral upper limg pressure waveform," American Journal of Hypertension, vol. 17, pp. 1059-1067, 2004.
    • (2004) American Journal of Hypertension , vol.17 , pp. 1059-1067
    • Gallagher, D.1    Adji, A.2    O'Rourke, M.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.