메뉴 건너뛰기




Volumn 24, Issue 9, 2004, Pages 688-692

The ductus venosus in early pregnancy and congenital anomalies

Author keywords

Congenital heart disease; Ductus venosus; Fetal aneuploidy; Trisomy 21

Indexed keywords

ACIDEMIA; ANEUPLOIDY; CONGENITAL HEART DISEASE; CONGENITAL MALFORMATION; DUCTUS VENOSUS; FETUS ECHOGRAPHY; FETUS HEART; FIRST TRIMESTER PREGNANCY; HUMAN; KARYOTYPE; PLACENTA; PRIORITY JOURNAL; REVIEW; TISSUE OXYGENATION; TRISOMY 21; VEIN BLOOD FLOW;

EID: 4644354649     PISSN: 01973851     EISSN: None     Source Type: Journal    
DOI: 10.1002/pd.958     Document Type: Review
Times cited : (42)

References (27)
  • 1
    • 0035020159 scopus 로고    scopus 로고
    • The role of ductus venosus blood flow assessment in screening for chromosomal abnormalities at 10-16 weeks of gestation
    • Antolin E, Comas C, Torrents M, et al. 2001. The role of ductus venosus blood flow assessment in screening for chromosomal abnormalities at 10-16 weeks of gestation. Ultrasound Obstet Gynecol 17: 295-300.
    • (2001) Ultrasound Obstet Gynecol , vol.17 , pp. 295-300
    • Antolin, E.1    Comas, C.2    Torrents, M.3
  • 3
    • 0344011695 scopus 로고    scopus 로고
    • Ductus venosus assessment at the time of nuchal translucency measurement in the detection of fetal aneuploidy
    • Borrell A, Martinez JM, Seres A, Borobio V, Cararach V, Fortuny A. 2003. Ductus venosus assessment at the time of nuchal translucency measurement in the detection of fetal aneuploidy. Prenal Diagn 23: 921-926.
    • (2003) Prenal Diagn , vol.23 , pp. 921-926
    • Borrell, A.1    Martinez, J.M.2    Seres, A.3    Borobio, V.4    Cararach, V.5    Fortuny, A.6
  • 4
    • 0035003790 scopus 로고    scopus 로고
    • Ductus venosus studies in fetuses at high risk for chromosomal or heart abnormalities: Relationship with nuchal translucency measurement and fetal outcome
    • Bilardo CM, Muller MA, Zikulnig L, Schipper M, Hecher K. 2001. Ductus venosus studies in fetuses at high risk for chromosomal or heart abnormalities: relationship with nuchal translucency measurement and fetal outcome. Ultrasound Obstet Gynecol 17: 288-294.
    • (2001) Ultrasound Obstet Gynecol , vol.17 , pp. 288-294
    • Bilardo, C.M.1    Muller, M.A.2    Zikulnig, L.3    Schipper, M.4    Hecher, K.5
  • 5
    • 84989096020 scopus 로고
    • Ductus venosus index: A method for evaluating right ventricular preload in the second-trimeter fetus
    • DeVore GR, Horenstein J. 1993. Ductus venosus index: a method for evaluating right ventricular preload in the second-trimeter fetus. Ultrasound Obstet Gynecol 3: 338-342.
    • (1993) Ultrasound Obstet Gynecol , vol.3 , pp. 338-342
    • DeVore, G.R.1    Horenstein, J.2
  • 6
    • 0037351548 scopus 로고    scopus 로고
    • The role of fetal nuchal translucency and ductus venosus doppler at 11-14 weeks of gestation in the detection of major congenital heart defects
    • Favre R, Cherif M, Kohler M, et al. 2003. The role of fetal nuchal translucency and ductus venosus doppler at 11-14 weeks of gestation in the detection of major congenital heart defects. Ultrasound Obstet Gynecol 21: 239-243.
    • (2003) Ultrasound Obstet Gynecol , vol.21 , pp. 239-243
    • Favre, R.1    Cherif, M.2    Kohler, M.3
  • 8
    • 0037341416 scopus 로고    scopus 로고
    • Ductus venosus flow velocities in relation to cardiac defects in first-trimester fetuses with enlarged nuchal translucency
    • Haak MC, Twisk JWR, Bartelings MM, Gittenberger-de Grood AC, van Vugt JMG. 2003. Ductus venosus flow velocities in relation to cardiac defects in first-trimester fetuses with enlarged nuchal translucency. Am J Obstet Gynecol 188: 727-733.
    • (2003) Am J Obstet Gynecol , vol.188 , pp. 727-733
    • Haak, M.C.1    Twisk, J.W.R.2    Bartelings, M.M.3    Gittenberger-De Grood, A.C.4    Van Vugt, J.M.G.5
  • 9
    • 0035022637 scopus 로고    scopus 로고
    • Assessment of ductus venosus flow during the first and early second trimesters: What can we expect
    • Hecher K. 2001. Assessment of ductus venosus flow during the first and early second trimesters: what can we expect (editorial). Ultrasound Obstet Gynecol 17: 285-287.
    • (2001) Ultrasound Obstet Gynecol , vol.17 , pp. 285-287
    • Hecher, K.1
  • 10
    • 0035685596 scopus 로고    scopus 로고
    • Monitoring of fetuses with intrauterine growth restriction: A longitudinal stud
    • Hecher K, Bilardo CM, Stigter RH, et al. 2001. Monitoring of fetuses with intrauterine growth restriction: a longitudinal stud. Ultrasound Obstet Gynecol 18: 564-570.
    • (2001) Ultrasound Obstet Gynecol , vol.18 , pp. 564-570
    • Hecher, K.1    Bilardo, C.M.2    Stigter, R.H.3
  • 11
    • 0031465781 scopus 로고    scopus 로고
    • Transient increase in nuchal translucency thickness and reversed end-diastolic ductus venosus flow in a fetus with trisomy 18
    • Huisman TWA, Bilardo CM. 1997. Transient increase in nuchal translucency thickness and reversed end-diastolic ductus venosus flow in a fetus with trisomy 18. Ultrasound Obstet Gynecol 10: 397-399.
    • (1997) Ultrasound Obstet Gynecol , vol.10 , pp. 397-399
    • Huisman, T.W.A.1    Bilardo, C.M.2
  • 13
  • 14
    • 0030759607 scopus 로고    scopus 로고
    • In a different vein: The ductus venosus could yield much valuable information
    • Kiserud T. 1997. In a different vein: the ductus venosus could yield much valuable information. Ultrasound Obstet Gynecol 9: 369-372.
    • (1997) Ultrasound Obstet Gynecol , vol.9 , pp. 369-372
    • Kiserud, T.1
  • 15
    • 0025718620 scopus 로고
    • Ultrasonographic velocimetry of the fetal ductus venosus
    • Kiserud T, Eik-Nes SH, Blaas H-G, Hellevik LR. 1991. Ultrasonographic velocimetry of the fetal ductus venosus. Lancet 338: 1412-1414.
    • (1991) Lancet , vol.338 , pp. 1412-1414
    • Kiserud, T.1    Eik-Nes, S.H.2    Blaas, H.-G.3    Hellevik, L.R.4
  • 18
  • 19
    • 0033377885 scopus 로고    scopus 로고
    • Cardiac defects in chromosomally normal fetuses with abnormal ductus venosus blood flow at 10-14 weeks
    • Matias A, Huggon I, Areias JC, Montenegro N, Nicolaides KH. 1999. Cardiac defects in chromosomally normal fetuses with abnormal ductus venosus blood flow at 10-14 weeks. Ultrasound Obstet Gynecol 14: 307-310.
    • (1999) Ultrasound Obstet Gynecol , vol.14 , pp. 307-310
    • Matias, A.1    Huggon, I.2    Areias, J.C.3    Montenegro, N.4    Nicolaides, K.H.5
  • 20
    • 0033932088 scopus 로고    scopus 로고
    • Anticipating twin-twin transfusion syndrome in monochorionic twin pregnancy. Is there a role for nuchal translucency and ductus venosus blood flow evaluation at 11-14 weeks?
    • Matias A, Montenegro N, Areias JC. 2004. Anticipating twin-twin transfusion syndrome in monochorionic twin pregnancy. Is there a role for nuchal translucency and ductus venosus blood flow evaluation at 11-14 weeks? Twin Res 3: 65-70.
    • (2004) Twin Res , vol.3 , pp. 65-70
    • Matias, A.1    Montenegro, N.2    Areias, J.C.3
  • 21
    • 0035015512 scopus 로고    scopus 로고
    • Intraobserver and interobserver variability of transabdominal doppler velocimetry measurements of the fetal ductus venosus between 10 and 14 weeks of gestation
    • Mavrides E, Holden D, Bland JM, Tekay A, Thilaganathan B. 2001. Intraobserver and interobserver variability of transabdominal doppler velocimetry measurements of the fetal ductus venosus between 10 and 14 weeks of gestation. Ultrasound Obstet Gynecol 17: 306-310.
    • (2001) Ultrasound Obstet Gynecol , vol.17 , pp. 306-310
    • Mavrides, E.1    Holden, D.2    Bland, J.M.3    Tekay, A.4    Thilaganathan, B.5
  • 22
    • 0036754198 scopus 로고    scopus 로고
    • Screening for aneuploidy in the first trimester by assessment of blood flow in the ductus venosus
    • Mavrides E, Sairam S, Hollis B, Thilaganathan B. 2002. Screening for aneuploidy in the first trimester by assessment of blood flow in the ductus venosus. Br J Obstet Gynaecol 109: 1015-1019.
    • (2002) Br J Obstet Gynaecol , vol.109 , pp. 1015-1019
    • Mavrides, E.1    Sairam, S.2    Hollis, B.3    Thilaganathan, B.4
  • 24
    • 0035993117 scopus 로고    scopus 로고
    • Application of ductus venosus doppler velocimetry for the detection of fetal aneuploidy in the first trimester of pregnancy
    • Murta CGV, Moron AF, Avila MAP, Weiner CP. 2002. Application of ductus venosus doppler velocimetry for the detection of fetal aneuploidy in the first trimester of pregnancy. Fetal Diagn Ther 17: 308-314.
    • (2002) Fetal Diagn Ther , vol.17 , pp. 308-314
    • Murta, C.G.V.1    Moron, A.F.2    Avila, M.A.P.3    Weiner, C.P.4
  • 25
    • 0035002423 scopus 로고    scopus 로고
    • Reproducibility of ductus venosus doppler flow measurements at 11-14 weeks of gestation
    • Prefumo F, De Basio P, Venturini PL. 2001. Reproducibility of ductus venosus doppler flow measurements at 11-14 weeks of gestation. Ultrasound Obstet Gynecol 17: 301-305.
    • (2001) Ultrasound Obstet Gynecol , vol.17 , pp. 301-305
    • Prefumo, F.1    De Basio, P.2    Venturini, P.L.3
  • 26
    • 0034483562 scopus 로고    scopus 로고
    • International society of ultrasound in obstetrics and gynecology safety statement 2000
    • Rapid Response Group. 2000. International society of ultrasound in obstetrics and gynecology safety statement 2000. Ultrasound Obstet Gynecol 16: 594-596.
    • (2000) Ultrasound Obstet Gynecol , vol.16 , pp. 594-596
  • 27
    • 0036156421 scopus 로고    scopus 로고
    • First-trimester ductus venosus velocimetry in relation to nuchal translucency thickness and fetal karyotype
    • Zoppi MA, Putzolu M, Ibba RM, Floris M, Monni G. 2002. First-trimester ductus venosus velocimetry in relation to nuchal translucency thickness and fetal karyotype. Fetal Diagn Ther 17: 52-57.
    • (2002) Fetal Diagn Ther , vol.17 , pp. 52-57
    • Zoppi, M.A.1    Putzolu, M.2    Ibba, R.M.3    Floris, M.4    Monni, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.