Volumn 13, Issue 5, 2004, Pages 413-416

Reliability of intraocular pressure by Tono-Pen XL over amniotic membrane patch in human

Author keywords

Amniotic membrane; Intraocular pressure; Tono Pen XL

Indexed keywords

ADULT; AMNION; ARTICLE; DEVICE; DIAGNOSTIC ACCURACY; EYE; FEMALE; HUMAN; INTRAOCULAR PRESSURE; MALE; NORMAL HUMAN; PRESSURE MEASUREMENT; PRIORITY JOURNAL; RELIABILITY;

EID: 4644345366     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ijg.0000132821.82950.52     Document Type: Article
Times cited : (14)

References (9)
  • 1
    • 0033796641 scopus 로고    scopus 로고
    • Amniotic membrane transplantation for acute chemical or thermal burns
    • Meller D, Pires RTF, Mack RJS, et al. Amniotic membrane transplantation for acute chemical or thermal burns. Ophthalmology. 2000;107:980-989.
    • (2000) Ophthalmology , vol.107 , pp. 980-989
    • Meller, D.1    Pires, R.T.F.2    Mack, R.J.S.3
  • 2
    • 0036583157 scopus 로고    scopus 로고
    • Thygeson lecture. Amniotic membrane transplantation: Why is it effective?
    • Baum J. Thygeson lecture. Amniotic membrane transplantation: why is it effective? Cornea. 2002;21:339-341.
    • (2002) Cornea , vol.21 , pp. 339-341
    • Baum, J.1
  • 3
    • 0037376818 scopus 로고    scopus 로고
    • Accuracy of intraocular pressure by Tono-Pen XL over amniotic membrane patching in rabbits
    • Kobayashi A, Yoshita T, Shirao Y. Accuracy of intraocular pressure by Tono-Pen XL over amniotic membrane patching in rabbits. Am J Ophthalmol. 2003;135:536-537.
    • (2003) Am J Ophthalmol , vol.135 , pp. 536-537
    • Kobayashi, A.1    Yoshita, T.2    Shirao, Y.3
  • 4
    • 0033777586 scopus 로고    scopus 로고
    • Accurate intraocular pressure measurement: The myth of modern ophthalmology
    • Shah S. Accurate intraocular pressure measurement: The myth of modern ophthalmology. Ophthalmology. 2000;107:1805-1807.
    • (2000) Ophthalmology , vol.107 , pp. 1805-1807
    • Shah, S.1
  • 5
    • 0031794457 scopus 로고
    • Positive correlation between Tono-Pen intraocular pressure and central corneal thickness
    • Dohadwala AA, Munger R, Damji KF. Positive correlation between Tono-Pen intraocular pressure and central corneal thickness. Ophthalmology. 1988;105:1849-1854.
    • (1988) Ophthalmology , vol.105 , pp. 1849-1854
    • Dohadwala, A.A.1    Munger, R.2    Damji, K.F.3
  • 6
    • 0023039008 scopus 로고
    • Noncontact tonometry through soft contact lenses
    • McMonnies CW. Noncontact tonometry through soft contact lenses. Am J Optom Physiol Opt. 1986;63:948-951.
    • (1986) Am J Optom Physiol Opt , vol.63 , pp. 948-951
    • McMonnies, C.W.1
  • 7
    • 0023261226 scopus 로고
    • Intraocular pressure by noncontat tonometry with and without soft contact lenses
    • Insler MS, Robbins RG. Intraocular pressure by noncontat tonometry with and without soft contact lenses. Arch Ophthalmol. 1987;105:1358-1359.
    • (1987) Arch Ophthalmol , vol.105 , pp. 1358-1359
    • Insler, M.S.1    Robbins, R.G.2
  • 8
    • 0025138421 scopus 로고
    • Intraocular pressure measurement with the Tono-Pen through soft contact lenses
    • Panek WC, Boothe WA, Lee DA, et al. Intraocular pressure measurement with the Tono-Pen through soft contact lenses. Am J Ophthalmol. 1990;109:62-65.
    • (1990) Am J Ophthalmol , vol.109 , pp. 62-65
    • Panek, W.C.1    Boothe, W.A.2    Lee, D.A.3
  • 9
    • 0024238583 scopus 로고
    • Accuracy and precision of the Tono-Pen in measuring intraocular pressure after keratoplasty and epikeratophakia and in scarred corneas
    • Rootman DS, Insler MS, Thompson HW, et al. Accuracy and precision of the Tono-Pen in measuring intraocular pressure after keratoplasty and epikeratophakia and in scarred corneas. Arch Ophthalmol. 1988;106:1697-1700.
    • (1988) Arch Ophthalmol , vol.106 , pp. 1697-1700
    • Rootman, D.S.1    Insler, M.S.2    Thompson, H.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.