-
1
-
-
0014273607
-
Complication rates of transfemoral and transaortic catheterization
-
Haut G, Amplatz K (1968) Complication rates of transfemoral and transaortic catheterization. Surgery 63:594-596
-
(1968)
Surgery
, vol.63
, pp. 594-596
-
-
Haut, G.1
Amplatz, K.2
-
2
-
-
0014783162
-
Arterial thrombus formation during clinical percutaneous catheterization
-
Formanek G, Frech RS, Amplatz K (1970) Arterial thrombus formation during clinical percutaneous catheterization. Circulation 41:833-839
-
(1970)
Circulation
, vol.41
, pp. 833-839
-
-
Formanek, G.1
Frech, R.S.2
Amplatz, K.3
-
3
-
-
0027524625
-
Case report: Thromboembolism during transfemoral arteriography- radiographic demonstration with histopathological correlation
-
Ooi GC, Jones AR, Rutty GN (1993) Case report: thromboembolism during transfemoral arteriography-radiographic demonstration with histopathological correlation. Clin Radiol 48:280-282
-
(1993)
Clin Radiol
, vol.48
, pp. 280-282
-
-
Ooi, G.C.1
Jones, A.R.2
Rutty, G.N.3
-
4
-
-
0037242961
-
Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms: Evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging
-
Soeda A, Sakai N, Sakai H, Iihara K, Yamada N, Imakita S, Nagata I (2003) Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms: evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging. Am J Neuroradiol 24:127-132
-
(2003)
Am J Neuroradiol
, vol.24
, pp. 127-132
-
-
Soeda, A.1
Sakai, N.2
Sakai, H.3
Iihara, K.4
Yamada, N.5
Imakita, S.6
Nagata, I.7
-
5
-
-
0019907047
-
Thrombogenicity of heparin- and non-heparin-coated catheters: Clinical trail
-
Kido DK, Paulin S, Alenghat JA, Waternaux C, Riley WD (1982) Thrombogenicity of heparin- and non-heparin-coated catheters: clinical trail. Am J Roentgenol 139:957-961
-
(1982)
Am J Roentgenol
, vol.139
, pp. 957-961
-
-
Kido, D.K.1
Paulin, S.2
Alenghat, J.A.3
Waternaux, C.4
Riley, W.D.5
-
7
-
-
0031106704
-
Development of chitosan/polyethylene vinyl acetate co-matrix: Controlled release of aspirin-heparin for preventing cardiovascular thrombosis
-
Vasudev SC, Chandy T, Sharma CP (1997) Development of chitosan/polyethylene vinyl acetate co-matrix: controlled release of aspirin-heparin for preventing cardiovascular thrombosis. Biomaterials 18:375-381
-
(1997)
Biomaterials
, vol.18
, pp. 375-381
-
-
Vasudev, S.C.1
Chandy, T.2
Sharma, C.P.3
-
8
-
-
0028999924
-
Prevention of venous thrombosis in microvascular surgery by transmural release of heparin from a polyanhydride polymer
-
Orloff LA, Glenn MG, Domb AJ, Esclamado RA (1995) Prevention of venous thrombosis in microvascular surgery by transmural release of heparin from a polyanhydride polymer. Surgery 117:554-559
-
(1995)
Surgery
, vol.117
, pp. 554-559
-
-
Orloff, L.A.1
Glenn, M.G.2
Domb, A.J.3
Esclamado, R.A.4
-
10
-
-
0024110681
-
Heparin immobilization onto segmented polyurethane-urea surfaces-effect of hydrophilic spacers
-
Park KD, Okano T, Nojiri C, Kim SW (1988) Heparin immobilization onto segmented polyurethane-urea surfaces-effect of hydrophilic spacers. J Biomed Mater Res 22:977-992
-
(1988)
J Biomed Mater Res
, vol.22
, pp. 977-992
-
-
Park, K.D.1
Okano, T.2
Nojiri, C.3
Kim, S.W.4
-
11
-
-
0019870874
-
Heparin bonding reduces thrombogenicity of pulmonary-artery catheters
-
Hoar PF, Wilson RM, Mangano DT, Avery GJ 2nd, Szarnicki RJ, Hill JD (1981) Heparin bonding reduces thrombogenicity of pulmonary-artery catheters. N Engl J Med 305:993-995
-
(1981)
N Engl J Med
, vol.305
, pp. 993-995
-
-
Hoar, P.F.1
Wilson, R.M.2
Mangano, D.T.3
Avery II, G.J.4
Szarnicki, R.J.5
Hill, J.D.6
-
12
-
-
0020493967
-
Heparin bonding and long-term protection against thrombogenesis
-
Mangano DT (1982) Heparin bonding and long-term protection against thrombogenesis. N Engl J Med 307:894-895
-
(1982)
N Engl J Med
, vol.307
, pp. 894-895
-
-
Mangano, D.T.1
-
13
-
-
0015805286
-
Reduction of the surgical complication rate by the use of a hypothrombogenic catheter coating
-
Cramer R, Moore R, Amplatz K (1973) Reduction of the surgical complication rate by the use of a hypothrombogenic catheter coating. Radiology 109:585-588
-
(1973)
Radiology
, vol.109
, pp. 585-588
-
-
Cramer, R.1
Moore, R.2
Amplatz, K.3
-
14
-
-
0031973452
-
Benefit of heparin in central venous and pulmonary artery catheters: A metaanalysis of randomized controlled trials
-
Randolph AG, Cook DJ, Gonzales CA, Andrew M (1998) Benefit of heparin in central venous and pulmonary artery catheters: a metaanalysis of randomized controlled trials. Chest 113:165-171
-
(1998)
Chest
, vol.113
, pp. 165-171
-
-
Randolph, A.G.1
Cook, D.J.2
Gonzales, C.A.3
Andrew, M.4
-
15
-
-
0028855178
-
Catheter-related thrombosis in critically ill children: Comparison of catheters with and without heparin bonding
-
Krafte-Jacobs B, Sivit CJ, Mejia R, Pollack MM (1995) Catheter-related thrombosis in critically ill children: comparison of catheters with and without heparin bonding. J Pediatr 126:50-54
-
(1995)
J Pediatr
, vol.126
, pp. 50-54
-
-
Krafte-Jacobs, B.1
Sivit, C.J.2
Mejia, R.3
Pollack, M.M.4
-
16
-
-
0020032442
-
Material hrombogenicity in central venous catheterization. I. A comparison between uncoated and heparin-coated, long antebrachial, polyethylene catheters
-
Bennegard K, Curelaru I, Gustavsson B, Linder LE, Zachrisson BF (1982) Material hrombogenicity in central venous catheterization. I. A comparison between uncoated and heparin-coated, long antebrachial, polyethylene catheters. Acta Anaesthesiol Scand 26:112-120
-
(1982)
Acta Anaesthesiol Scand
, vol.26
, pp. 112-120
-
-
Bennegard, K.1
Curelaru, I.2
Gustavsson, B.3
Linder, L.E.4
Zachrisson, B.F.5
-
17
-
-
0023341581
-
An in vitro study of the adhesion of blood platelets onto vascular catheters. Part I
-
Engbers GH, Dost L, Hennink WE, Aarts PA, Sixma JJ, Feijen J (1987) An in vitro study of the adhesion of blood platelets onto vascular catheters. Part I. J Biomed Mater Res 21:613-627
-
(1987)
J Biomed Mater Res
, vol.21
, pp. 613-627
-
-
Engbers, G.H.1
Dost, L.2
Hennink, W.E.3
Aarts, P.A.4
Sixma, J.J.5
Feijen, J.6
-
19
-
-
0029585675
-
Thrombin generation during cardiopulmonary bypass using heparin-coated or standard circuits
-
Ernofsson M, Thelin S, Siegbahn A (1995) Thrombin generation during cardiopulmonary bypass using heparin-coated or standard circuits. Scand J Thorac Cardiovasc Surg 29:157-165
-
(1995)
Scand J Thorac Cardiovasc Surg
, vol.29
, pp. 157-165
-
-
Ernofsson, M.1
Thelin, S.2
Siegbahn, A.3
-
20
-
-
0023201846
-
Casting solvent effects on the permeability of polymer films of differing quaternary ammonium (cation) content
-
Okor RS, Anderson W (1987) Casting solvent effects on the permeability of polymer films of differing quaternary ammonium (cation) content. J Pharm Pharmacol 39:547-548
-
(1987)
J Pharm Pharmacol
, vol.39
, pp. 547-548
-
-
Okor, R.S.1
Anderson, W.2
-
21
-
-
0032533809
-
Preparation of slightly hydrophobic heparin derivatives which can be used for solvent casting in polymeric formulation
-
Lee Y, Moon HT, Byun Y (1998) Preparation of slightly hydrophobic heparin derivatives which can be used for solvent casting in polymeric formulation. Thromb Res 92:149-156
-
(1998)
Thromb Res
, vol.92
, pp. 149-156
-
-
Lee, Y.1
Moon, H.T.2
Byun, Y.3
-
22
-
-
0035255936
-
A novel formulation for controlled release of heparin-DOCA conjugate dispersed as nanoparticles in polyurethane film
-
Moon HT, Lee YK, Han JK, Byun Y (2001) A novel formulation for controlled release of heparin-DOCA conjugate dispersed as nanoparticles in polyurethane film. Biomaterials 22:281-289
-
(2001)
Biomaterials
, vol.22
, pp. 281-289
-
-
Moon, H.T.1
Lee, Y.K.2
Han, J.K.3
Byun, Y.4
-
23
-
-
0033854080
-
Heparin-bonded central venous lines reduce thrombotic and infective complications in critically ill children
-
Pierce CM, Wade A, Mok Q (2000) Heparin-bonded central venous lines reduce thrombotic and infective complications in critically ill children. Intensive Care Med 26:967-972
-
(2000)
Intensive Care Med
, vol.26
, pp. 967-972
-
-
Pierce, C.M.1
Wade, A.2
Mok, Q.3
-
24
-
-
0027537448
-
Surface antimicrobial activity of heparin-bonded and antiseptic- impregnated vascular catheters
-
Mermel LA, Stolz SM, Maki DG (1993) Surface antimicrobial activity of heparin- bonded and antiseptic-impregnated vascular catheters. J Infect Dis 167:920-924
-
(1993)
J Infect Dis
, vol.167
, pp. 920-924
-
-
Mermel, L.A.1
Stolz, S.M.2
Maki, D.G.3
-
25
-
-
0023444169
-
Long-term stability in vivo of a thromboresistant heparinized surface
-
Arnander C, Bagger-Sjoback D, Frebelius S, Larsson R, Swedenborg J (1987) Long-term stability in vivo of a thromboresistant heparinized surface. Biomaterials 8:496-499
-
(1987)
Biomaterials
, vol.8
, pp. 496-499
-
-
Arnander, C.1
Bagger-Sjoback, D.2
Frebelius, S.3
Larsson, R.4
Swedenborg, J.5
-
26
-
-
0017155514
-
A new, simple test for thrombogenicity
-
Amplatz K (1976) A new, simple test for thrombogenicity. Radiology 120:53-55
-
(1976)
Radiology
, vol.120
, pp. 53-55
-
-
Amplatz, K.1
-
27
-
-
0015183410
-
A simple noninvasive technique to test nonthrombogenic surfaces. Direct visualization of experimental thrombus formation around guidewires
-
Frech RS, Cramer R, Amplatz K (1971) A simple noninvasive technique to test nonthrombogenic surfaces. Direct visualization of experimental thrombus formation around guidewires. Am J Roentgenol Radium Ther Nucl Med 113:765-768
-
(1971)
Am J Roentgenol Radium Ther Nucl Med
, vol.113
, pp. 765-768
-
-
Frech, R.S.1
Cramer, R.2
Amplatz, K.3
-
28
-
-
0015598368
-
Flow cell evaluation of nonthrombogenic materials
-
Durst S, Cramer R, Amplatz K (1973) Flow cell evaluation of nonthrombogenic materials. Radiology 106:507-511
-
(1973)
Radiology
, vol.106
, pp. 507-511
-
-
Durst, S.1
Cramer, R.2
Amplatz, K.3
-
29
-
-
0007468557
-
The coating of intravascular plastic prostheses with colloidal graphite
-
Gott VL, Koepke DE, Daggett RL (1961) The coating of intravascular plastic prostheses with colloidal graphite. Surgery 50:382-389
-
(1961)
Surgery
, vol.50
, pp. 382-389
-
-
Gott, V.L.1
Koepke, D.E.2
Daggett, R.L.3
-
30
-
-
0015104151
-
A preliminary human study with a simple nonthrombogenic catheter
-
Cramer R, Frech RS, Amplatz K (1971) A preliminary human study with a simple nonthrombogenic catheter. Radiology 100:421-422
-
(1971)
Radiology
, vol.100
, pp. 421-422
-
-
Cramer, R.1
Frech, R.S.2
Amplatz, K.3
|