메뉴 건너뛰기




Volumn 20, Issue 5, 2004, Pages 444-449

One-year results of photorefractive keratectomy with and without surface smoothing using the Technolas 217C laser

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; DEVICE; EXCIMER LASER; EYE REFRACTION; FEMALE; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MALE; MYOPIA; PHOTOREFRACTIVE KERATECTOMY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; STATISTICAL ANALYSIS; SURGICAL TECHNIQUE; TOPOGRAPHY; VISUAL ACUITY;

EID: 4644308084     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20040901-06     Document Type: Article
Times cited : (13)

References (29)
  • 1
    • 0036189248 scopus 로고    scopus 로고
    • Spot size and quality of scanning laser correction of higher-order wavefront aberrations
    • Huang D, Arif M. Spot size and quality of scanning laser correction of higher-order wavefront aberrations. J Cataract Refract Surg 2002;28:407-416.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 407-416
    • Huang, D.1    Arif, M.2
  • 2
    • 0032038042 scopus 로고    scopus 로고
    • A method for examining surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis: Predictor of optical and functional outcomes
    • Vinciguerra P, Azzolini M, Radice P, Sborgia M, De Molfetta V. A method for examining surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis: Predictor of optical and functional outcomes. J Refract Surg 1998;14:S204-S206.
    • (1998) J Refract Surg , vol.14
    • Vinciguerra, P.1    Azzolini, M.2    Radice, P.3    Sborgia, M.4    De Molfetta, V.5
  • 3
    • 0031923091 scopus 로고    scopus 로고
    • Effect of decreasing surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis on optical and functional outcomes
    • Vinciguerra P, Azzolini M, Airaghi P, Radice P, De Molfetta V. Effect of decreasing surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis on optical and functional outcomes. J Refract Surg 1998;14:S199-S203
    • (1998) J Refract Surg , vol.14
    • Vinciguerra, P.1    Azzolini, M.2    Airaghi, P.3    Radice, P.4    De Molfetta, V.5
  • 7
    • 0034917344 scopus 로고    scopus 로고
    • Wound healing response in the presence of stromal irregularities after excimer laser treatment
    • Weber BA, Gan L, Fagerholm P. Wound healing response in the presence of stromal irregularities after excimer laser treatment. Acta Ophthalmol Scand 2001;79:381-388.
    • (2001) Acta Ophthalmol Scand , vol.79 , pp. 381-388
    • Weber, B.A.1    Gan, L.2    Fagerholm, P.3
  • 8
    • 0033789256 scopus 로고    scopus 로고
    • Determining the accuracy of an eye tracking system for laser refractive surgery
    • Taylor NM, Eikelboom RH, van Sarloos PP, Reid PG. Determining the accuracy of an eye tracking system for laser refractive surgery. J Refract Surg 2000;16:S643-S646.
    • (2000) J Refract Surg , vol.16
    • Taylor, N.M.1    Eikelboom, R.H.2    Van Sarloos, P.P.3    Reid, P.G.4
  • 9
    • 0034828694 scopus 로고    scopus 로고
    • Broad beam vs. flying spot excimer laser: Refractive and videokeratographic outcomes of two different ablation profiles after photorefractive keratectomy
    • Fiore T, Carones F, Brancato R. Broad beam vs. flying spot excimer laser: refractive and videokeratographic outcomes of two different ablation profiles after photorefractive keratectomy. J Refract Surg 2001;17:534-541.
    • (2001) J Refract Surg , vol.17 , pp. 534-541
    • Fiore, T.1    Carones, F.2    Brancato, R.3
  • 12
    • 0034971023 scopus 로고    scopus 로고
    • Correction of irregular astigmatism with excimer laser assisted by sodium hyaluronate
    • Alio JL, Belda JI, Shalaby AM. Correction of irregular astigmatism with excimer laser assisted by sodium hyaluronate. Ophthalmology 2001;108:1246-1260.
    • (2001) Ophthalmology , vol.108 , pp. 1246-1260
    • Alio, J.L.1    Belda, J.I.2    Shalaby, A.M.3
  • 14
    • 0027446198 scopus 로고
    • Determination of corneal image-forming properties from corneal topography
    • Maloney RK, Bogan SJ, Waring GO III. Determination of corneal image-forming properties from corneal topography. Am J Ophthalmol 1993;115:31-41.
    • (1993) Am J Ophthalmol , vol.115 , pp. 31-41
    • Maloney, R.K.1    Bogan, S.J.2    Waring III, G.O.3
  • 15
    • 0026335678 scopus 로고
    • Excimer laser smoothing of a reproducible model of anterior corneal surface irregularity
    • Fasano AP, Moreira H, McDonnel PJ, Sinbaway A. Excimer laser smoothing of a reproducible model of anterior corneal surface irregularity. Ophthalmology 1991;98-1782-1785.
    • (1991) Ophthalmology , vol.98 , pp. 1782-1785
    • Fasano, A.P.1    Moreira, H.2    McDonnel, P.J.3    Sinbaway, A.4
  • 16
    • 0033060176 scopus 로고    scopus 로고
    • Phototherapeutic smoothing as an adjunct to photorefractive keratectomy in porcine corneas
    • Horgan SE, McLaughlin-Borlace L, Stevens JD, Munro PMG. Phototherapeutic smoothing as an adjunct to photorefractive keratectomy in porcine corneas. J Refract Surg 1999;15:331-333.
    • (1999) J Refract Surg , vol.15 , pp. 331-333
    • Horgan, S.E.1    McLaughlin-Borlace, L.2    Stevens, J.D.3    Munro, P.M.G.4
  • 17
    • 0025909335 scopus 로고
    • A comparative study of masking fluids for excimer laser phototherapeutic keratectomy
    • Kornmehl EW, Steinert RF, Puliafito CA. A comparative study of masking fluids for excimer laser phototherapeutic keratectomy. Arch Ophthalmol 1991;109:860-863.
    • (1991) Arch Ophthalmol , vol.109 , pp. 860-863
    • Kornmehl, E.W.1    Steinert, R.F.2    Puliafito, C.A.3
  • 19
    • 0034004702 scopus 로고    scopus 로고
    • Effect of porosity and surface hydrophilicity on migration of epithelial tissue over synthetic polymer
    • Steele JG, Johnson G, McLean KM, Beumer GJ, Griesser HJ. Effect of porosity and surface hydrophilicity on migration of epithelial tissue over synthetic polymer. J Biomed Mater Res 2000;50:475-482.
    • (2000) J Biomed Mater Res , vol.50 , pp. 475-482
    • Steele, J.G.1    Johnson, G.2    McLean, K.M.3    Beumer, G.J.4    Griesser, H.J.5
  • 20
    • 0030973528 scopus 로고    scopus 로고
    • Molecular cell biology for the refractive corneal surgeon: Programmed cell death and wound healing
    • Wilson SE. Molecular cell biology for the refractive corneal surgeon: programmed cell death and wound healing. J Refract Surg 1997;13:171-175.
    • (1997) J Refract Surg , vol.13 , pp. 171-175
    • Wilson, S.E.1
  • 21
    • 0035009375 scopus 로고    scopus 로고
    • Immunohistochemical study of subepithelial haze after phototherapeutic keratectomy
    • Lee YC, Wang IJ, Hu FR, Kao WWY. Immunohistochemical study of subepithelial haze after phototherapeutic keratectomy. J Refract Surg 2001;17:334-341.
    • (2001) J Refract Surg , vol.17 , pp. 334-341
    • Lee, Y.C.1    Wang, I.J.2    Hu, F.R.3    Kao, W.W.Y.4
  • 22
    • 0034982496 scopus 로고    scopus 로고
    • The wound healing response after laser in situ keratomileusis and photorefractive keratectomy: Elusive control of biological variability and effect on custom laser vision correction
    • Wilson Se, Mohan RR, Hong JW, Lee JS, Choi R, Mohan RR. The wound healing response after laser in situ keratomileusis and photorefractive keratectomy: elusive control of biological variability and effect on custom laser vision correction. Arch Ophthalmol 2001;119:889-896.
    • (2001) Arch Ophthalmol , vol.119 , pp. 889-896
    • Wilson, Se.1    Mohan, R.R.2    Hong, J.W.3    Lee, J.S.4    Choi, R.5    Mohan, R.R.6
  • 23
    • 0032759248 scopus 로고    scopus 로고
    • Long-term follow-up of excimer laser phototherapeutic keratectomy
    • Amano S, Oshika T, Tazawa Y, Tsuru T. Long-term follow-up of excimer laser phototherapeutic keratectomy. Jpn J Ophthalmol 1999;43:513-516.
    • (1999) Jpn J Ophthalmol , vol.43 , pp. 513-516
    • Amano, S.1    Oshika, T.2    Tazawa, Y.3    Tsuru, T.4
  • 24
    • 0035018411 scopus 로고    scopus 로고
    • Refractive changes after excimer laser phototherapeutic keratectomy
    • Dogru M, Katakami C, Yamanaka A. Refractive changes after excimer laser phototherapeutic keratectomy. J Cataract Refract Surg 2001;27:686-692.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 686-692
    • Dogru, M.1    Katakami, C.2    Yamanaka, A.3
  • 25
    • 0026564557 scopus 로고
    • Hyperopic shift and the use of masking agents in excimer laser superficial keratectomy
    • Liu C. Hyperopic shift and the use of masking agents in excimer laser superficial keratectomy. Br J Ophthalmol 1992;76:62-63.
    • (1992) Br J Ophthalmol , vol.76 , pp. 62-63
    • Liu, C.1
  • 26
    • 0038779618 scopus 로고    scopus 로고
    • Phototherapeutic keratectomy: 12 Years of experience
    • Fagerholm P. Phototherapeutic keratectomy: 12 years of experience. Acta Ophthalmol Scand 2003;81:19-32.
    • (2003) Acta Ophthalmol Scand , vol.81 , pp. 19-32
    • Fagerholm, P.1
  • 27
    • 0029399365 scopus 로고
    • Tapered transition zone and surface smoothing ameliorate the results of excimer-laser photorefractive keratectomy for myopia
    • Schipper I, Senn P, Lechner A. Tapered transition zone and surface smoothing ameliorate the results of excimer-laser photorefractive keratectomy for myopia. Ger J Ophthalmol 1995;4:368-373.
    • (1995) Ger J Ophthalmol , vol.4 , pp. 368-373
    • Schipper, I.1    Senn, P.2    Lechner, A.3
  • 28
    • 0037244955 scopus 로고    scopus 로고
    • Photorefractive keratectomy with and without smoothing: A bilateral study
    • Serrao S, Lombardo M, Mondini F. Photorefractive keratectomy with and without smoothing: a bilateral study. J Refract Surg 2003;19:58-64.
    • (2003) J Refract Surg , vol.19 , pp. 58-64
    • Serrao, S.1    Lombardo, M.2    Mondini, F.3