메뉴 건너뛰기




Volumn 110, Issue 1-4, 2004, Pages 839-843

First microdosimetric measurements with a TEPC based on a GEM

Author keywords

[No Author keywords available]

Indexed keywords

CALIFORNIUM 252;

EID: 4644307552     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch144     Document Type: Article
Times cited : (26)

References (9)
  • 1
    • 0029773860 scopus 로고    scopus 로고
    • Microdosimetry of monoenergetic neutrons
    • Srdoc, D. and Marino, S. A. Microdosimetry of monoenergetic neutrons. Radiat. Res. 146, 466-474 (1996).
    • (1996) Radiat. Res. , vol.146 , pp. 466-474
    • Srdoc, D.1    Marino, S.A.2
  • 2
    • 0025123135 scopus 로고
    • Measurement of single event energy deposition spectra at 5 nm to 250 nm simulated site size
    • Kliauga, P. Measurement of single event energy deposition spectra at 5 nm to 250 nm simulated site size. Radiat. Prot. Dosim. 31, 119-123 (1990).
    • (1990) Radiat. Prot. Dosim. , vol.31 , pp. 119-123
    • Kliauga, P.1
  • 4
    • 0037150007 scopus 로고    scopus 로고
    • Characterization of miniature tissue-equivalent proportional counters for neutron radiotherapy application
    • Burmeister, J., Kota, C., Maughan R. L. and Waker, A. J. Characterization of miniature tissue-equivalent proportional counters for neutron radiotherapy application. Phys. Med. Biol. 47(10), 1633-1645 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , Issue.10 , pp. 1633-1645
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3    Waker, A.J.4
  • 5
    • 0031074683 scopus 로고    scopus 로고
    • GEM: A new concept for electron amplification in gas detectors
    • Sauli, F., GEM: A new concept for electron amplification in gas detectors. Nucl. Instrum. Meth. A 386, 531-534 (1997).
    • (1997) Nucl. Instrum. Meth. A , vol.386 , pp. 531-534
    • Sauli, F.1
  • 6
    • 0038715739 scopus 로고    scopus 로고
    • Gas Electron Multiplier (GEM operation with tissue-equivalent gases at various pressures
    • Farahmand, M., Bos, A. J. J. and van Eijk, C. W. E. Gas Electron Multiplier (GEM operation with tissue-equivalent gases at various pressures. Nucl. Instrum. Meth. A 506, 160-165 (2003).
    • (2003) Nucl. Instrum. Meth. A , vol.506 , pp. 160-165
    • Farahmand, M.1    Bos, A.J.J.2    van Eijk, C.W.E.3
  • 7
    • 0042229054 scopus 로고    scopus 로고
    • Design of a new tissue-equivalent proportional counter based on a gas electron multiplier
    • Farahmand, M., Bos, A. J. J., Huizenga, J., De Nardo, L. and van Eijk, C. W. E. Design of a new tissue-equivalent proportional counter based on a gas electron multiplier. Nucl. Instrum. Meth. A 509, 262-267 (2003).
    • (2003) Nucl. Instrum. Meth. A , vol.509 , pp. 262-267
    • Farahmand, M.1    Bos, A.J.J.2    Huizenga, J.3    De Nardo, L.4    van Eijk, C.W.E.5
  • 8
    • 0009965875 scopus 로고
    • International Commission on Radiation Units and Measurements. Microdosimetry
    • ICRU Report 36 (Bethesda, MD: ICRU)
    • International Commission on Radiation Units and Measurements. Microdosimetry. ICRU Report 36 (Bethesda, MD: ICRU) (1983).
    • (1983)