메뉴 건너뛰기




Volumn 27, Issue 6, 2004, Pages 488-494

Analysis of red blood cell aggregation in cardio-pulmonary bypass (CPB) surgery

Author keywords

Algorithms; Cardiopulmonary bypass; Red blood cell aggregation

Indexed keywords

BLOOD; CELLS; CYTOLOGY; SURGERY;

EID: 4644307513     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139880402700607     Document Type: Article
Times cited : (2)

References (14)
  • 1
    • 0025230650 scopus 로고
    • The influence of extracorporeal circulation and hemoseparation on red cell deformability and membrane proteins in coronary artery disease
    • Lohrer RM, Trammer AR, Dietrich W, Hagl S, Linderkamp O. The influence of extracorporeal circulation and hemoseparation on red cell deformability and membrane proteins in coronary artery disease. J Thorac Cardiovasc Surg 1990; 99: 735-40.
    • (1990) J. Thorac Cardiovasc. Surg. , vol.99 , pp. 735-740
    • Lohrer, R.M.1    Trammer, A.R.2    Dietrich, W.3    Hagl, S.4    Linderkamp, O.5
  • 2
    • 0033492637 scopus 로고    scopus 로고
    • Decrease in red blood cell deformability caused by hypothermia, hemodilution, and mechanical stress: Factors related to cardiopulmonary bypass
    • Kameneva MV, Undar A, Antaki JF, Watach MJ, Calhoon JH, Borovetz HS. Decrease in red blood cell deformability caused by hypothermia, hemodilution, and mechanical stress: factors related to cardiopulmonary bypass. ASAIO J 1999; 45: 307-10.
    • (1999) ASAIO J. , vol.45 , pp. 307-310
    • Kameneva, M.V.1    Undar, A.2    Antaki, J.F.3    Watach, M.J.4    Calhoon, J.H.5    Borovetz, H.S.6
  • 3
    • 0024471661 scopus 로고
    • Evaluation of a method to assess red blood cell aggregation
    • Chabanel A, Samama M. Evaluation of a method to assess red blood cell aggregation. Biorheology 1989; 26: 785-97.
    • (1989) Biorheology , vol.26 , pp. 785-797
    • Chabanel, A.1    Samama, M.2
  • 4
    • 84975624531 scopus 로고
    • Reduced light-scattering properties for mixtures of spherical particles: A simple approximation derived from Mie calculations
    • Graaff R, Aarnoudse JG, Zijp JR, Sloot PMA, Mul FFM de, Greve J, Koelink MH. Reduced light-scattering properties for mixtures of spherical particles: A simple approximation derived from Mie calculations. Appl Opt 1992; 31: 1370-76.
    • (1992) Appl. Opt. , vol.31 , pp. 1370-1376
    • Graaff, R.1    Aarnoudse, J.G.2    Zijp, J.R.3    Sloot, P.M.A.4    Mul, F.F.M.5    de Greve, J.6    Koelink, M.H.7
  • 6
    • 5144222713 scopus 로고
    • Quantitative studies on rouleaux formation of erythrocytes by reflection measurement (syllectometry)
    • Dissertation, University of Groningen, The Netherlands. Groningen: Van Denderen
    • Jansonius NJ. Quantitative studies on rouleaux formation of erythrocytes by reflection measurement (syllectometry). Dissertation, University of Groningen, The Netherlands. Groningen: Van Denderen, 1959.
    • (1959)
    • Jansonius, N.J.1
  • 7
    • 70149120878 scopus 로고
    • Quantitative evaluation of the rate of rouleaux formation of erythrocytes. Syllectometry
    • Assen, The Netherlands: Van Gorcum
    • Zijlstra WG, Mook GA. Quantitative evaluation of the rate of rouleaux formation of erythrocytes. Syllectometry. In: Medical reflection photometry. Assen, The Netherlands: Van Gorcum, 1962; pp. 250-70.
    • (1962) Medical Reflection Photometry , pp. 250-270
    • Zijlstra, W.G.1    Mook, G.A.2
  • 8
    • 5144231296 scopus 로고
    • Various factors influencing rouleaux formation of erythrocytes, studied with the aid of syllectometry
    • Jansonius NJ, Zijlstra WG. Various factors influencing rouleaux formation of erythrocytes, studied with the aid of syllectometry. Kon Ned Acad Wet C 1965; 68: 121-7.
    • (1965) Kon. Ned. Acad. Wet. C. , vol.68 , pp. 121-127
    • Jansonius, N.J.1    Zijlstra, W.G.2
  • 11
    • 0035663596 scopus 로고    scopus 로고
    • The laser-assisted optical rotational cell analyser (LORCA) as red blood cell aggregometer
    • Hardeman MR, Dobbe JGG, Ince C. The laser-assisted optical rotational cell analyser (LORCA) as red blood cell aggregometer. Clin Hemorheol Microcirc 2001; 25: 1-11.
    • (2001) Clin. Hemorheol. Microcirc. , vol.25 , pp. 1-11
    • Hardeman, M.R.1    Dobbe, J.G.G.2    Ince, C.3
  • 12
    • 0027983577 scopus 로고
    • Laser-assist optical rotational cell analyser (LORCA): I A new instrument for measurement of various hemorheological structural parameters
    • Hardeman MR, Goedhart PT, Dobbe JGG, Lettinga KP. Laser-assist optical rotational cell analyser (LORCA): I A new instrument for measurement of various hemorheological structural parameters. Clin Hemorheol 1994; 14: 605-18.
    • (1994) Clin. Hemorheol. , vol.14 , pp. 605-618
    • Hardeman, M.R.1    Goedhart, P.T.2    Dobbe, J.G.G.3    Lettinga, K.P.4
  • 14
    • 0038638407 scopus 로고    scopus 로고
    • Hyperaggregating effect of hydroxyethyl starch components and University of Wisconsin solution on human red blood cells: A risk of impaired graft perfusion in organ procurement?
    • Morariu AM, Plaats A van der, Oeveren W van, et al. Hyperaggregating effect of hydroxyethyl starch components and University of Wisconsin solution on human red blood cells: A risk of impaired graft perfusion in organ procurement? Transplantation 2003; 76: 37-43.
    • (2003) Transplantation , vol.76 , pp. 37-43
    • Morariu, A.M.1    van der Plaats, A.2    van Oeveren, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.