메뉴 건너뛰기




Volumn 110, Issue 1-4, 2004, Pages 503-507

Characterisation of neutron fields around high-energy x-ray radiotherapy machines

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CONTROLLED STUDY; NEUTRON DOSIMETRY; NEUTRON RADIATION; RADIATION DETECTION; RADIATION ENERGY; RADIATION FIELD; RADIOTHERAPY; SPECTROMETER; X RAY;

EID: 4644291340     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch274     Document Type: Article
Times cited : (26)

References (12)
  • 1
    • 0015313138 scopus 로고
    • Neutron production from electron accelerators
    • Axton, A. J. and Bardell, A. G. Neutron production ftom electron accelerators. Phys. Med. Biol. 17, 293-298 (1972).
    • (1972) Phys. Med. Biol. , vol.17 , pp. 293-298
    • Axton, A.J.1    Bardell, A.G.2
  • 2
    • 4644289656 scopus 로고
    • Photoneutron production in neutron detectors
    • (Letters to the Editor)
    • Axton, A. J. and Bardell, A. G. Photoneutron production in neutron detectors (Letters to the Editor). Nucl. Instrum. Meth. 155, 563 (1978).
    • (1978) Nucl. Instrum. Meth. , vol.155 , pp. 563
    • Axton, A.J.1    Bardell, A.G.2
  • 5
    • 0018777441 scopus 로고
    • Neutron dosimetry in high energy X-ray beams of medical accelerators
    • Sohrabi, M. and Morgan, K. Z. Neutron dosimetry in high energy X-ray beams of medical accelerators. Phys. Med. Biol. 24(4) 756-766 (1979).
    • (1979) Phys. Med. Biol. , vol.24 , Issue.4 , pp. 756-766
    • Sohrabi, M.1    Morgan, K.Z.2
  • 6
    • 0017929851 scopus 로고
    • Transport of accelerator produced neutrons in a concrete room
    • NS-26
    • McCall, R. C., Jenkins, T. M. and Shore, R. A. Transport of accelerator produced neutrons in a concrete room. IEEE Trans. Nucl. Sci., NS-26(1), 1593-1602 (1979).
    • (1979) IEEE Trans. Nucl. Sci. , Issue.1 , pp. 1593-1602
    • McCall, R.C.1    Jenkins, T.M.2    Shore, R.A.3
  • 7
    • 4644353102 scopus 로고
    • 3He proportional counter determined by Monte Carlo calculations
    • Report CMI-GR 2070/95, Prague
    • 3He proportional counter determined by Monte Carlo calculations. Report CMI-GR 2070/95, Prague (1995).
    • (1995)
    • Králik, M.1    Novotný, T.2
  • 8
    • 0007046906 scopus 로고    scopus 로고
    • Calibration of the CMI Bonner sphere spectrometer
    • Report CMI 911-01/97, Prague
    • Novotný, T. and Králik, M. Calibration of the CMI Bonner sphere spectrometer. Report CMI 911-01/97, Prague (1997).
    • (1997)
    • Novotný, T.1    Králik, M.2
  • 9
    • 4644324078 scopus 로고
    • Electrochemical etching of damaged track detectors by H.V.- pulse and sinusoidal waveform
    • Report Lab. Dosimetria e Standardizzazione CNEN, Casaccia, Rome
    • Tommasino, L. Electrochemical etching of damaged track detectors by H.V.- pulse and sinusoidal waveform. Report Lab. Dosimetria e Standardizzazione CNEN, Casaccia, Rome (1970).
    • (1970)
    • Tommasino, L.1
  • 10
    • 33244491612 scopus 로고    scopus 로고
    • The 'few channel' unfolding programs in the UMG package
    • UMG Package, Version 3.1, 5 August (Braunschweig: PTB)
    • Reginatto, M. The 'few channel' unfolding programs in the UMG package. UMG Package, Version 3.1, 5 August (Braunschweig: PTB) (2002).
    • (2002)
    • Reginatto, M.1
  • 11
    • 0004159251 scopus 로고    scopus 로고
    • Conversion coefficients for use in radiological protection against external radiation
    • International Commission on Radiological Protection. ICRP Publication 74. Ann. ICRP (Oxford: Pergamon Press)
    • International Commission on Radiological Protection. Conversion coefficients for use in radiological protection against external radiation. ICRP Publication 74. Ann. ICRP 26(3/4) (Oxford: Pergamon Press) (1996).
    • (1996) , vol.26 , Issue.3-4
  • 12
    • 0004159249 scopus 로고    scopus 로고
    • Conversion coefficients for use in radiological protection against external radiation
    • International Commission on Radiation Units and Measurements. ICRU Report 57 (Bethesda, MD: ICRU)
    • International Commission on Radiation Units and Measurements. Conversion coefficients for use in radiological protection against external radiation. ICRU Report 57 (Bethesda, MD: ICRU) (1998).
    • (1998)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.