Volumn 50, Issue 10, 2004, Pages 1881-1883

Measurement of total homocysteine concentrations in acidic citrate- and EDTA-containing tubes by different methods [4]

Author keywords

[No Author keywords available]

Indexed keywords

ANTICOAGULANT AGENT; CITRIC ACID; EDETIC ACID; HOMOCYSTEINE;

EID: 4644285569     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/clinchem.2004.040634     Document Type: Letter
Times cited : (4)

References (8)
  • 3
    • 0027462812 scopus 로고
    • Homocysteine and other thiols in plasma and urine: Automated determination and sample stability
    • Fiskerstrand T, Refsum H, Kvalheim G, Ueland PM. Homocysteine and other thiols in plasma and urine: automated determination and sample stability. Clin Chem 1993;39:263-71.
    • (1993) Clin Chem , vol.39 , pp. 263-271
    • Fiskerstrand, T.1    Refsum, H.2    Kvalheim, G.3    Ueland, P.M.4
  • 5
    • 0023628783 scopus 로고
    • Determination of free and total homocysteine in human plasma by high-performance liquid chromatography with fluorescence detection
    • Araki A, Sako Y. Determination of free and total homocysteine in human plasma by high-performance liquid chromatography with fluorescence detection. J Chromatogr 1987;422:43-52.
    • (1987) J Chromatogr , vol.422 , pp. 43-52
    • Araki, A.1    Sako, Y.2
  • 6
    • 0025848779 scopus 로고
    • Rapid high-performance liquid chromatographic assay for total homocysteine levels in human serum
    • Ubbink JB, Hayward Vermaak WJ, Bissbort S. Rapid high-performance liquid chromatographic assay for total homocysteine levels in human serum. J Chromatogr 1991;565:441-6.
    • (1991) J Chromatogr , vol.565 , pp. 441-446
    • Ubbink, J.B.1    Hayward Vermaak, W.J.2    Bissbort, S.3
  • 7
    • 0029035643 scopus 로고
    • Rapid, fully automated measurement of plasma homocyst(e)ine with the Abbott IMx analyzer
    • Shipchandler MT, Moore EG. Rapid, fully automated measurement of plasma homocyst(e)ine with the Abbott IMx analyzer. Clin Chem 1995;41:991-4.
    • (1995) Clin Chem , vol.41 , pp. 991-994
    • Shipchandler, M.T.1    Moore, E.G.2
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing of agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing of agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2