메뉴 건너뛰기




Volumn 10, Issue , 2002, Pages 109-116

Complications associated with endovascular repair of abdominal aortic aneurysm

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ANEURYSM RUPTURE; ANEURYSM SURGERY; ARTERY DIAMETER; ARTIFICIAL EMBOLISM; CLAUDICATION; COLON ISCHEMIA; ENDOLEAK; ENDOVASCULAR SURGERY; FOLLOW UP; FOOD AND DRUG ADMINISTRATION; HUMAN; IMPOTENCE; INCIDENCE; NEUROLOGIC DISEASE; PATIENT SELECTION; POSTOPERATIVE COMPLICATION; REVIEW; RISK ASSESSMENT; STENOSIS; THROMBOSIS;

EID: 4644267482     PISSN: 10697292     EISSN: None     Source Type: Book Series    
DOI: None     Document Type: Review
Times cited : (3)

References (27)
  • 1
    • 0035111942 scopus 로고    scopus 로고
    • Aorto-uni-iliac endograft for complex aortoiliac aneurysms compared with tube/bifurcation endografts: Results of the EVT/Guidant trials
    • Moore WS, Brewster DC, Bernhard VM: Aorto-uni-iliac endograft for complex aortoiliac aneurysms compared with tube/bifurcation endografts: Results of the EVT/Guidant trials. J Vasc Surg 33:S11-S20, 2001.
    • (2001) J Vasc Surg , vol.33
    • Moore, W.S.1    Brewster, D.C.2    Bernhard, V.M.3
  • 2
    • 0032972728 scopus 로고    scopus 로고
    • AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trial
    • Zarins CK, White RA, Schwarten D, et al: AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trial. J Vasc Surg 29:292-305, 1999.
    • (1999) J Vasc Surg , vol.29 , pp. 292-305
    • Zarins, C.K.1    White, R.A.2    Schwarten, D.3
  • 3
    • 0031905820 scopus 로고    scopus 로고
    • Concurrent comparison of endoluminal versus open repair in the treatment of abdominal aortic aneurysms: Analysis of 303 patients by life table method
    • May J, White GH, Yu W, et al: Concurrent comparison of endoluminal versus open repair in the treatment of abdominal aortic aneurysms: Analysis of 303 patients by life table method. J Vasc Surg 27:213-220, 1998.
    • (1998) J Vasc Surg , vol.27 , pp. 213-220
    • May, J.1    White, G.H.2    Yu, W.3
  • 4
    • 0035105293 scopus 로고    scopus 로고
    • Age versus comorbidities as risk factors for complications after elective abdominal aortic reconstructive surgery
    • Berry AJ, Smith RB III, Weintraub WS, et al: Age versus comorbidities as risk factors for complications after elective abdominal aortic reconstructive surgery. J Vasc Surg 33:345-352, 2001.
    • (2001) J Vasc Surg , vol.33 , pp. 345-352
    • Berry, A.J.1    Smith III, R.B.2    Weintraub, W.S.3
  • 5
    • 0036111140 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysms: Risk stratified outcomes
    • Chaikof EL, Lin PH, Brinkman WT, et al: Endovascular repair of abdominal aortic aneurysms: Risk stratified outcomes. Ann Surg 235:833-841, 2002.
    • (2002) Ann Surg , vol.235 , pp. 833-841
    • Chaikof, E.L.1    Lin, P.H.2    Brinkman, W.T.3
  • 6
    • 0032854007 scopus 로고    scopus 로고
    • Special iliac artery considerations during aneurysm endografting
    • Henretta JP, Karch LA, Hodgson KJ, et al: Special iliac artery considerations during aneurysm endografting. Am J Surg 178:212-218, 1999.
    • (1999) Am J Surg , vol.178 , pp. 212-218
    • Henretta, J.P.1    Karch, L.A.2    Hodgson, K.J.3
  • 7
    • 0032104405 scopus 로고    scopus 로고
    • Endovascular repair of abdominal aortic aneurysm: Getting out of trouble
    • Chuter TA, Reilly LM, Kerlan RK, et al: Endovascular repair of abdominal aortic aneurysm: Getting out of trouble. Cardiovasc Surg 6:232-239, 1998.
    • (1998) Cardiovasc Surg , vol.6 , pp. 232-239
    • Chuter, T.A.1    Reilly, L.M.2    Kerlan, R.K.3
  • 8
    • 0031978889 scopus 로고    scopus 로고
    • Common iliac artery aneurysms in patients with abdominal aortic aneurysms
    • Armon MP, Wenham PW, Whitaker SC, et al: Common iliac artery aneurysms in patients with abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 15:255-257, 1998.
    • (1998) Eur J Vasc Endovasc Surg , vol.15 , pp. 255-257
    • Armon, M.P.1    Wenham, P.W.2    Whitaker, S.C.3
  • 9
    • 17144467266 scopus 로고    scopus 로고
    • Unilateral and bilateral hypogastric artery interruption during aortoiliac aneurysm repair in 154 patients: A relatively innocuous procedure
    • Mehta M, Veith FJ, Ohki T, et al: Unilateral and bilateral hypogastric artery interruption during aortoiliac aneurysm repair in 154 patients: A relatively innocuous procedure. J Vasc Surg 33:S27-S32, 2001.
    • (2001) J Vasc Surg , vol.33
    • Mehta, M.1    Veith, F.J.2    Ohki, T.3
  • 10
    • 0035348250 scopus 로고    scopus 로고
    • Outcome after unilateral hypogastric artery occlusion during endovascular aneurysm repair
    • Lee WA, O'Dorisio J, Wolf YG, et al: Outcome after unilateral hypogastric artery occlusion during endovascular aneurysm repair. J Vasc Surg 33:921-926, 2001.
    • (2001) J Vasc Surg , vol.33 , pp. 921-926
    • Lee, W.A.1    O'Dorisio, J.2    Wolf, Y.G.3
  • 11
    • 0035115532 scopus 로고    scopus 로고
    • Midterm durability of abdominal aortic aneurysm endograft repair: A word of caution
    • Holzenbein TJ, Kretschmer G, Thurnher S, et al: Midterm durability of abdominal aortic aneurysm endograft repair: A word of caution. J Vasc Surg 33:S46-S54, 2001.
    • (2001) J Vasc Surg , vol.33
    • Holzenbein, T.J.1    Kretschmer, G.2    Thurnher, S.3
  • 12
    • 1642336911 scopus 로고    scopus 로고
    • Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: A note of caution based on a 9-year experience
    • Ohki T, Veith FJ, Shaw P, et al: Increasing incidence of midterm and long-term complications after endovascular graft repair of abdominal aortic aneurysms: A note of caution based on a 9-year experience. Ann Surg 234:323-335, 2001.
    • (2001) Ann Surg , vol.234 , pp. 323-335
    • Ohki, T.1    Veith, F.J.2    Shaw, P.3
  • 13
    • 0035433259 scopus 로고    scopus 로고
    • Serious complications that require surgical interventions after endoluminal stent-graft placement for the treatment of infrarenal aortic aneurysms
    • Schlensak C, Doenst T, Hauer M, et al: Serious complications that require surgical interventions after endoluminal stent-graft placement for the treatment of infrarenal aortic aneurysms. J Vasc Surg 34:198-203, 2001.
    • (2001) J Vasc Surg , vol.34 , pp. 198-203
    • Schlensak, C.1    Doenst, T.2    Hauer, M.3
  • 14
    • 0035111944 scopus 로고    scopus 로고
    • Mid-term results after endovascular repair of the abdominal aortic aneurysm
    • Bush RL, Lumsden AB, Dodson TF, et al: Mid-term results after endovascular repair of the abdominal aortic aneurysm. J Vasc Surg 33:S70-S76, 2001.
    • (2001) J Vasc Surg , vol.33
    • Bush, R.L.1    Lumsden, A.B.2    Dodson, T.F.3
  • 15
    • 0033775550 scopus 로고    scopus 로고
    • Limb kinking in supported and unsupported abdominal aortic stem-grafts
    • Baum RA, Shetty SK, Carpenter JP, et al: Limb kinking in supported and unsupported abdominal aortic stem-grafts. J Vasc Interv Radiol 11: 1165-1171, 2000.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1165-1171
    • Baum, R.A.1    Shetty, S.K.2    Carpenter, J.P.3
  • 16
    • 85018942269 scopus 로고    scopus 로고
    • Detection of isolated hook fractures 36 months after implantation of the Ancure endograft: A cautionary note
    • Najibi S, Steinberg J, Katzen BT, et al: Detection of isolated hook fractures 36 months after implantation of the Ancure endograft: A cautionary note. J Vasc Surg 34:353-356, 2001.
    • (2001) J Vasc Surg , vol.34 , pp. 353-356
    • Najibi, S.1    Steinberg, J.2    Katzen, B.T.3
  • 17
    • 0346348015 scopus 로고    scopus 로고
    • Identification and implications of transgraft microleaks after endovascular repair of aortic aneurysms
    • Matsumura JS, Ryu RK, Ouriel K: Identification and implications of transgraft microleaks after endovascular repair of aortic aneurysms. J Vasc Surg 34:190-197, 2001.
    • (2001) J Vasc Surg , vol.34 , pp. 190-197
    • Matsumura, J.S.1    Ryu, R.K.2    Ouriel, K.3
  • 18
    • 0035111634 scopus 로고    scopus 로고
    • Results of an aortic endograft trial: Impact of device failure beyond 12 months
    • Beebe HG, Cronenwett JL, Katzen BT, et al: Results of an aortic endograft trial: Impact of device failure beyond 12 months. J Vasc Surg 33:S55-S63, 2001.
    • (2001) J Vasc Surg , vol.33
    • Beebe, H.G.1    Cronenwett, J.L.2    Katzen, B.T.3
  • 19
    • 0034911604 scopus 로고    scopus 로고
    • Corroded nitinol wires in explanted aortic endografts: An important mechanism of failure?
    • Heintz C, Riepe G, Birken L, et al: Corroded nitinol wires in explanted aortic endografts: An important mechanism of failure? J Endovasc Ther 8:248-253, 2001.
    • (2001) J Endovasc Ther , vol.8 , pp. 248-253
    • Heintz, C.1    Riepe, G.2    Birken, L.3
  • 20
    • 0031689178 scopus 로고    scopus 로고
    • Continued expansion of aortic necks after endovascular repair of abdominal aortic aneurysms
    • Matsumura JS, Chaikof EL: Continued expansion of aortic necks after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 28:422-430, 1998.
    • (1998) J Vasc Surg , vol.28 , pp. 422-430
    • Matsumura, J.S.1    Chaikof, E.L.2
  • 21
    • 0035115320 scopus 로고    scopus 로고
    • Concerns for the durability of the proximal abdominal aortic aneurysm endograft fixation from a 2-year and 3-year longitudinal computed tomography angiography study
    • Prinssen M, Wever JJ, Mali WP, et al: Concerns for the durability of the proximal abdominal aortic aneurysm endograft fixation from a 2-year and 3-year longitudinal computed tomography angiography study. J Vasc Surg 33:S64-S69, 2001.
    • (2001) J Vasc Surg , vol.33
    • Prinssen, M.1    Wever, J.J.2    Mali, W.P.3
  • 22
    • 0036481881 scopus 로고    scopus 로고
    • Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years
    • Cao P, Verzini F, Zannetti S, et al: Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years. J Vasc Surg 35:229-235, 2002.
    • (2002) J Vasc Surg , vol.35 , pp. 229-235
    • Cao, P.1    Verzini, F.2    Zannetti, S.3
  • 24
    • 0036597160 scopus 로고    scopus 로고
    • Ruptured abdominal aortic aneurysm following endovascular repair
    • Bernhard VM, Mitchell RS, Matsumura JS, et al: Ruptured abdominal aortic aneurysm following endovascular repair. J Vasc Surg 35:1155-1162, 2002.
    • (2002) J Vasc Surg , vol.35 , pp. 1155-1162
    • Bernhard, V.M.1    Mitchell, R.S.2    Matsumura, J.S.3
  • 25
    • 0031821534 scopus 로고    scopus 로고
    • Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter
    • Resch T, Ivancev K, Lindh M, et al: Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter. J Vasc Surg 28:242-249, 1998.
    • (1998) J Vasc Surg , vol.28 , pp. 242-249
    • Resch, T.1    Ivancev, K.2    Lindh, M.3
  • 26
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris PL, Vallabhaneni SR, Desgranges P, et al: Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience. J Vasc Surg 32:739-749, 2000.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 27
    • 0035118542 scopus 로고    scopus 로고
    • The AneuRx stent graft: Four-year results and worldwide experience 2000
    • Zarins CK, White RA, Moll FL, et al: The AneuRx stent graft: Four-year results and worldwide experience 2000. J Vasc Surg 33:S135-S145, 2001.
    • (2001) J Vasc Surg , vol.33
    • Zarins, C.K.1    White, R.A.2    Moll, F.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.