메뉴 건너뛰기




Volumn 37, Issue 11, 2004, Pages 2259-2266

Potentiometric, enantioselective electrode responsive to propranolol enantiomers based on a lipophilic β-cyclodextrin

Author keywords

Cyclodextrin; Drug analysis; Enantioselective sensor; Potentiometry; Propranolol

Indexed keywords

2 HYDROXY 3 TRIMETHYLAMMONIOPROPYL BETA CYCLODEXTRIN; ADIPIC ACID; BETA CYCLODEXTRIN; BIS(T BUTYLPHENTYL) ADIPATE; CALCIUM; ETHER DERIVATIVE; IONOPHORE; ORTHO NITROPHENYL OCTYL ETHER; PLASTICIZER; POTASSIUM; PROPANOL; SALBUTAMOL; SODIUM; UNCLASSIFIED DRUG; ZINC;

EID: 4644256161     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-200028059     Document Type: Article
Times cited : (13)

References (16)
  • 2
    • 0027732756 scopus 로고
    • Enantioselective bioanalysis of beta-blocking agents: Focus on atenolol, betaxolol, carvedilol, metoprolol, pindolol, propranolol and sotalol
    • and references cited therein
    • Egginger, G.; Lindner, W.; Vandenbosch, C.; Massart, D.L. Enantioselective bioanalysis of beta-blocking agents: focus on atenolol, betaxolol, carvedilol, metoprolol, pindolol, propranolol and sotalol. Biomed. Chromatogr. 1993, 7, 278-295 (and references cited therein).
    • (1993) Biomed. Chromatogr. , vol.7 , pp. 278-295
    • Egginger, G.1    Lindner, W.2    Vandenbosch, C.3    Massart, D.L.4
  • 3
    • 0030022677 scopus 로고    scopus 로고
    • Importance of stereospecific bioanalytical monitoring in drug development
    • Caldwell, J. Importance of stereospecific bioanalytical monitoring in drug development. J. Chromatogr. A 1996, 719, 3-13.
    • (1996) J. Chromatogr. A , vol.719 , pp. 3-13
    • Caldwell, J.1
  • 4
    • 0026733594 scopus 로고
    • The chiral chromatographic separation of β-adrenoceptor blocking drugs
    • Dyas, A.M. The chiral chromatographic separation of β-adrenoceptor blocking drugs. J. Pharm. Biomed. Anal. 1992, 10, 383-404.
    • (1992) J. Pharm. Biomed. Anal. , vol.10 , pp. 383-404
    • Dyas, A.M.1
  • 6
    • 0142157870 scopus 로고    scopus 로고
    • Enantioselective electrochemical sensors
    • Baltes, H., Fedder, G.K., Korvink, J.G., Eds.; Wiley-VCH: Weinheim, Germany, Chap. 2.1
    • Stefan, R.I.; Aboul-Enein, H.Y.; van Staden, J.F. Enantioselective electrochemical sensors. In Sensors Update; Baltes, H., Fedder, G.K., Korvink, J.G., Eds.; Wiley-VCH: Weinheim, Germany, 2002; Vol. 10, 123-141, Chap. 2.1.
    • (2002) Sensors Update , vol.10 , pp. 123-141
    • Stefan, R.I.1    Aboul-Enein, H.Y.2    Van Staden, J.F.3
  • 7
    • 0037566171 scopus 로고    scopus 로고
    • Enantiomer-selectivity of ion-selective electrodes based on a chiral crown-ether ionophore
    • Horvath, V.; Takacs, T.; Horvai, G.; Huszthy, P.; Bradshaw, J.S.; Izatt, R.M. Enantiomer-selectivity of ion-selective electrodes based on a chiral crown-ether ionophore. Anal. Lett. 1997, 30 (9), 1591-1609.
    • (1997) Anal. Lett. , vol.30 , Issue.9 , pp. 1591-1609
    • Horvath, V.1    Takacs, T.2    Horvai, G.3    Huszthy, P.4    Bradshaw, J.S.5    Izatt, R.M.6
  • 8
    • 0000529273 scopus 로고
    • Functionalized α-cyclodextrins as potentiometric chiral sensors
    • Kataky, R.; Bates, P.S.; Parker, D. Functionalized α-cyclodextrins as potentiometric chiral sensors. Analyst 1992, 117, 1313-1317.
    • (1992) Analyst , vol.117 , pp. 1313-1317
    • Kataky, R.1    Bates, P.S.2    Parker, D.3
  • 9
    • 37049075192 scopus 로고
    • Functionalized cyclodextrins as potentiometric chiral sensors
    • Bates, P.S.; Kataky, R.; Parker, D. Functionalized cyclodextrins as potentiometric chiral sensors. Analyst 1994, 119, 181-186.
    • (1994) Analyst , vol.119 , pp. 181-186
    • Bates, P.S.1    Kataky, R.2    Parker, D.3
  • 10
    • 37049088538 scopus 로고
    • Chiral sensors based on lipophilic cyclodextrins: Interrogation of enantioselectivity by combined NMR, structural correlation and electrode response studies
    • Bates, P.S.; Kataky, R.; Parker, D. Chiral sensors based on lipophilic cyclodextrins: interrogation of enantioselectivity by combined NMR, structural correlation and electrode response studies. J. Chem. Soc. Perkin Trans. 2 1994, 669-675.
    • (1994) J. Chem. Soc. Perkin Trans. 2 , pp. 669-675
    • Bates, P.S.1    Kataky, R.2    Parker, D.3
  • 11
    • 0029100256 scopus 로고
    • Potentiometric, enantioselective sensors for alkyl and aryl ammonium ions of pharmaceutical significance, based on lipophilic cyclodextrin
    • Kataky, R.; Parker, D.; Kelly, P.M. Potentiometric, enantioselective sensors for alkyl and aryl ammonium ions of pharmaceutical significance, based on lipophilic cyclodextrin. Scand. J. Clin. Lab. Invest. 1995, 55, 409-419.
    • (1995) Scand. J. Clin. Lab. Invest. , vol.55 , pp. 409-419
    • Kataky, R.1    Parker, D.2    Kelly, P.M.3
  • 12
    • 0001197264 scopus 로고    scopus 로고
    • Selective complexation and sensitive analysis of charge diffuse cationic species using lipophilic cyclodextrins
    • Parker, D.; Kataky, R. Selective complexation and sensitive analysis of charge diffuse cationic species using lipophilic cyclodextrins. Chem. Commun. 1997, 141-145.
    • (1997) Chem. Commun. , pp. 141-145
    • Parker, D.1    Kataky, R.2
  • 13
    • 0005068914 scopus 로고    scopus 로고
    • Ion-selective electrode for the determination of the beta-adrenergic drug clenbuterol
    • Sun, X.X.; Ding, H.L. Ion-selective electrode for the determination of the beta-adrenergic drug clenbuterol. Fenxi Shiyanshi 1999, 18, 75-79.
    • (1999) Fenxi Shiyanshi , vol.18 , pp. 75-79
    • Sun, X.X.1    Ding, H.L.2
  • 14
    • 0034661533 scopus 로고    scopus 로고
    • Improved detection limits and unbiased selectivity coefficients obtained by using ion-exchange resins in the inner reference solution of ion-selective polymeric membrane electrode
    • Qin, W.; Zwickl, T.; Pretsch, E. Improved detection limits and unbiased selectivity coefficients obtained by using ion-exchange resins in the inner reference solution of ion-selective polymeric membrane electrode. AC 2000, 72, 3236-3240.
    • (2000) AC , vol.72 , pp. 3236-3240
    • Qin, W.1    Zwickl, T.2    Pretsch, E.3
  • 15
    • 0000495604 scopus 로고    scopus 로고
    • Effects of ion transport on the potential response of ionophore-based membrane electrodes: A theoretical approach
    • Morf, W.E.; Badertscher, M.; Zwickl, T.; de Rooij, N.F.; Pretsch, E. Effects of ion transport on the potential response of ionophore-based membrane electrodes: a theoretical approach. J. Phys. Chem. B 1999, 103, 11346-11356.
    • (1999) J. Phys. Chem. B , vol.103 , pp. 11346-11356
    • Morf, W.E.1    Badertscher, M.2    Zwickl, T.3    De Rooij, N.F.4    Pretsch, E.5
  • 16
    • 0034449742 scopus 로고    scopus 로고
    • A novel ion selective PVC membrane electrode for determination of propranolol in pharmaceutical formulation
    • Aboul-Enein, H.Y.; Sun, X.X. A novel ion selective PVC membrane electrode for determination of propranolol in pharmaceutical formulation. Analysis 2000, 28, 855-858.
    • (2000) Analysis , vol.28 , pp. 855-858
    • Aboul-Enein, H.Y.1    Sun, X.X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.