메뉴 건너뛰기




Volumn 14, Issue 3, 2004, Pages 157-162

Combined HRCT and MRI in the detection of CSF rhinorrhea

Author keywords

CSF rhinorrhea; High resolution CT; MRI cisternography

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CEREBROSPINAL FLUID RHINORRHEA; CHILD; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC PROCEDURE; FEMALE; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; IMAGE ANALYSIS; INFANT; INTERMETHOD COMPARISON; MALE; MEDICAL DECISION MAKING; NEWBORN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SENSITIVITY ANALYSIS; SURGICAL TECHNIQUE; TREATMENT PLANNING;

EID: 4644253772     PISSN: 15315010     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-832259     Document Type: Article
Times cited : (50)

References (13)
  • 2
    • 18844469453 scopus 로고    scopus 로고
    • Methods of identification and localization of ethmoid and sphenoid osteomeningeal breaches
    • Schmerber S, Boubagra K, Cuisnier O, Righini C, Reyt E. Methods of identification and localization of ethmoid and sphenoid osteomeningeal breaches. Rev Laryngol Otol Rhinol 2001;122(1):13-19
    • (2001) Rev. Laryngol. Otol. Rhinol. , vol.122 , Issue.1 , pp. 13-19
    • Schmerber, S.1    Boubagra, K.2    Cuisnier, O.3    Righini, C.4    Reyt, E.5
  • 3
    • 0028821819 scopus 로고
    • Localization of inactive cerebrospinal fistulas
    • Eljamel MS, Pidgeon CN. Localization of inactive cerebrospinal fistulas. J Neurosurg 1995;83:795-798
    • (1995) J. Neurosurg. , vol.83 , pp. 795-798
    • Eljamel, M.S.1    Pidgeon, C.N.2
  • 4
    • 0031219313 scopus 로고    scopus 로고
    • Magnetic resonance cisternography and thin coronal computerized tomography in the evaluation of cerebrospinal fluid rhinorrhea
    • Sillers MJ, Morgan CE, El Gammal T. Magnetic resonance cisternography and thin coronal computerized tomography in the evaluation of cerebrospinal fluid rhinorrhea. Am J Rhinol 1997;11(5):387-392
    • (1997) Am. J. Rhinol. , vol.11 , Issue.5 , pp. 387-392
    • Sillers, M.J.1    Morgan, C.E.2    El Gammal, T.3
  • 5
    • 0031242043 scopus 로고    scopus 로고
    • Experiences with assessment of frontobasal defects, a diagnostic concept
    • Simmen D, Bischoff T, Schuknecht B. Experiences with assessment of frontobasal defects, a diagnostic concept. Laryngorhinootologie 1997;76(10):583-587
    • (1997) Laryngorhinootologie , vol.76 , Issue.10 , pp. 583-587
    • Simmen, D.1    Bischoff, T.2    Schuknecht, B.3
  • 6
    • 0032231340 scopus 로고    scopus 로고
    • Evaluation of high-resolution CT and MR cisternography in the diagnosis of cerebrospinal fluid fistula
    • Shetty PG, Shroff MM, Sahani DV, Kirtane MV. Evaluation of high-resolution CT and MR cisternography in the diagnosis of cerebrospinal fluid fistula. Am J Neuroradiol 1998;19:633-639
    • (1998) Am. J. Neuroradiol. , vol.19 , pp. 633-639
    • Shetty, P.G.1    Shroff, M.M.2    Sahani, D.V.3    Kirtane, M.V.4
  • 7
    • 0034490843 scopus 로고    scopus 로고
    • Optimum imaging and diagnosis of cerebrospinal fluid rhinorrhea
    • Lund VJ, Savy L, Lloyd G, Howard D. Optimum imaging and diagnosis of cerebrospinal fluid rhinorrhea. J Laryngol Otol 2000;114:988-992
    • (2000) J. Laryngol. Otol. , vol.114 , pp. 988-992
    • Lund, V.J.1    Savy, L.2    Lloyd, G.3    Howard, D.4
  • 8
    • 0027285618 scopus 로고
    • CT cisternography in the investigation of cerebrospinal fluid rhinorrhea
    • Colquhoun IR. CT cisternography in the investigation of cerebrospinal fluid rhinorrhea. Clin Radiol 1993;47(6): 403-408
    • (1993) Clin. Radiol. , vol.47 , Issue.6 , pp. 403-408
    • Colquhoun, I.R.1
  • 9
    • 0027954054 scopus 로고
    • MRI cisternography, and the localization of CSF fistula
    • Eljamel MS, Pidgeon CN, Toland J, et al. MRI cisternography, and the localization of CSF fistula. Br J Neurosurg 1994;8(4):433-437
    • (1994) Br. J. Neurosurg. , vol.8 , Issue.4 , pp. 433-437
    • Eljamel, M.S.1    Pidgeon, C.N.2    Toland, J.3
  • 10
    • 0032231696 scopus 로고    scopus 로고
    • Cerebrospinal fluid fistula: Detection with MR cisternography
    • El Gammal T, Sobol W, Wadlington VR. Cerebrospinal fluid fistula: detection with MR cisternography. Am J Neuroradiol 1998;19:627-631
    • (1998) Am. J. Neuroradiol. , vol.19 , pp. 627-631
    • El Gammal, T.1    Sobol, W.2    Wadlington, V.R.3
  • 11
    • 0029162649 scopus 로고
    • MRI in spontaneous cerebrospinal fluid rhinorrhea
    • Murata Y, Yamada I, Suzuki S. MRI in spontaneous cerebrospinal fluid rhinorrhea. Neuroradiology 1995;37(6): 453-455
    • (1995) Neuroradiology , vol.37 , Issue.6 , pp. 453-455
    • Murata, Y.1    Yamada, I.2    Suzuki, S.3
  • 13
    • 0029162108 scopus 로고
    • Flow-sensitive magnetic resonance imaging in the evaluation of cerebrospinal fluid leaks
    • Levy LM, Gulya AJ, Davis SW, LeBihan D, Rajan SS, Schellinger D. Flow-sensitive magnetic resonance imaging in the evaluation of cerebrospinal fluid leaks. Am J Otol 1995;16(5):591-596
    • (1995) Am. J. Otol. , vol.16 , Issue.5 , pp. 591-596
    • Levy, L.M.1    Gulya, A.J.2    Davis, S.W.3    LeBihan, D.4    Rajan, S.S.5    Schellinger, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.