메뉴 건너뛰기




Volumn 36, Issue 1, 2001, Pages 77-86

Development of voxelised numerical phantoms using MCNP Monte Carlo code: Application to in vivo measurement

Author keywords

241Am; calibration; lungs; Monte Carlo; phantom, mathematical

Indexed keywords

CALIBRATION FACTORS; CALIBRATION PHANTOM; COMPUTING TECHNIQUES; IN-VIVO MEASUREMENT; LUNGS; MATHEMATICAL PHANTOMS; PHANTOM, MATHEMATICAL; TISSUE COMPOSITION;

EID: 4644250455     PISSN: 00338451     EISSN: 1769700X     Source Type: Journal    
DOI: 10.1051/radiopro:2001112     Document Type: Article
Times cited : (9)

References (10)
  • 2
    • 0030041940 scopus 로고    scopus 로고
    • The gender-specific chest Wall thickness prediction equations for routine measurements of 239Pu and 24'Am within the lungs using HPGe detectors
    • Vikers L.R. (1 996) The gender-specific chest Wall thickness prediction equations for routine measurements of 239Pu and 24'Am within the lungs using HPGe detectors, Health Phys. 70, 346-357.
    • (1996) Health Phys. , vol.70 , pp. 346-357
    • Vikers, L.R.1
  • 3
    • 0007964843 scopus 로고    scopus 로고
    • Les mesures anthroporadiamétriques dans les basses énergies : évolution technologique et hases des recherches futures
    • Franck D., de Carlan L., Berard Ph., Dousse C., Pihet P., Razafindralambo N., Soulie R. (1997) Les mesures anthroporadiamétriques dans les basses énergies : évolution technologique et hases des recherches futures, Radioprotection 32 ,685-696.
    • (1997) Radioprotection , vol.32 , pp. 685-696
    • Franck, D.1    De Carlan, L.2    Berard, Ph.3    Dousse, C.4    Pihet, P.5    Razafindralambo, N.6    Soulie, R.7
  • 4
    • 0031686815 scopus 로고    scopus 로고
    • Calibration of an in vivo measurement system using avoxei phantom
    • Hunt J.G., Dantas B.M., Lucena E. (1998) Calibration of an in vivo measurement system using avoxei phantom, Radiai. Prot. Dosim. 79,425-427.
    • (1998) Radiai. Prot. Dosim. , vol.79 , pp. 425-427
    • Hunt, J.G.1    Dantas, B.M.2    Lucena, E.3
  • 5
    • 0003266016 scopus 로고
    • Tissue suhstitutes in radiation dosimetry and meaurements
    • KRU, ICRU Publication, Bethesda
    • KRU (1989) Tissue Suhstitutes in Radiation Dosimetry and Meaurements. ICRU Report 44, ICRU Publication, Bethesda.
    • (1989) ICRU Report , pp. 44
  • 6
    • 0029054765 scopus 로고
    • Development of a method for calihrating in vivo measurement systems using magnetic resonnance imaging an Monte Carlo computation
    • Mallet M.W., Hickman D.P., Krutchen D.A., Poston J.W. (1995) Development of a method for calihrating in vivo measurement systems using magnetic resonnance imaging an Monte Carlo computation, Healih Phys. 68,773-785.
    • (1995) Healih Phys. , vol.68 , pp. 773-785
    • Mallet, M.W.1    Hickman, D.P.2    Krutchen, D.A.3    Poston, J.W.4
  • 8
    • 77953927630 scopus 로고
    • Version 3.56, Radiation Transport Group - Applied Theoreticai Physics Division - Los Alamos National Lahoratory, LA-UR
    • Kenneth A.V. (1994) Sabrina user's guide for Sahrina, Version 3.56, Radiation Transport Group - Applied Theoreticai Physics Division - Los Alamos National Lahoratory, LA-UR-93-3696.
    • (1994) Sabrina User's Guide for Sahrina , pp. 93-3696
    • Kenneth, A.V.1
  • 9
    • 0003233865 scopus 로고    scopus 로고
    • Validation of the MCNP4h Monte Carlo code for germanium detector gamma efficiency calihration
    • Bronson F.L., Wang L. (1996) Validation of the MCNP4h Monte Carlo code for germanium detector gamma efficiency calihration, Proceedings of wmte management Tucson AZ.
    • (1996) Proceedings of Wmte Management Tucson AZ
    • Bronson, F.L.1    Wang, L.2
  • 10
    • 0006998590 scopus 로고    scopus 로고
    • Organ dose Calculations using Monte Carlo Method and Realistic Voxel Phantom
    • Xu X.G., Chao T.C., Bozkurt A., Eckennan K.F. (1999) Organ dose Calculations using Monte Carlo Method and Realistic Voxel Phantom, Medical Phys. 26, 1175-1 176.
    • (1999) Medical Phys. , vol.26 , pp. 1175-1176
    • Xu, X.G.1    Chao, T.C.2    Bozkurt, A.3    Eckennan, K.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.