메뉴 건너뛰기




Volumn 66, Issue 4, 2004, Pages 1512-1516

Static intra-access pressure ratio does not correlate with access blood flow: Rapid communication

Author keywords

Access blood flow; Access surveillance; Static intra access pressure ratio

Indexed keywords

ARTERIOVENOUS FISTULA; ARTERIOVENOUS SHUNT; ARTICLE; BLOOD FLOW; BLOOD FLOWMETRY; BLOOD PRESSURE; BLOOD VESSEL OCCLUSION; BLOOD VESSEL PARAMETERS; CONTROLLED STUDY; HEMODYNAMIC MONITORING; HUMAN; MAJOR CLINICAL STUDY; PATIENT MONITORING; PRACTICE GUIDELINE; PRIORITY JOURNAL; STATIC INTRA ACCESS PRESSURE RATIO; VASCULAR ACCESS;

EID: 4644250236     PISSN: 00852538     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1523-1755.2004.00946.x     Document Type: Article
Times cited : (26)

References (15)
  • 1
    • 0035228229 scopus 로고    scopus 로고
    • K/DOW clinical practice guidelines for vascular access
    • NATIONAL KIDNEY FOUNDATION: K/DOW clinical practice guidelines for vascular access. Am J Kidney Dis 37(Suppl 1):S137-S181, 2001
    • (2001) Am J Kidney Dis , vol.37 , Issue.SUPPL. 1
  • 2
    • 0031937755 scopus 로고    scopus 로고
    • Simplified measurement of intra-access pressure
    • BESARAB A, FRINAK S, SHERMAN RA, et al: Simplified measurement of intra-access pressure. J Am Soc Nephrol 9:284-289, 1998
    • (1998) J Am Soc Nephrol , vol.9 , pp. 284-289
    • Besarab, A.1    Frinak, S.2    Sherman, R.A.3
  • 3
    • 0030250777 scopus 로고    scopus 로고
    • Simplified measurement of intra-access pressure
    • BESARAB A, AL-SAGHIR F, ALNABHAN N, et al: Simplified measurement of intra-access pressure. ASAIO J 42:M682-M687, 1996
    • (1996) ASAIO J , vol.42
    • Besarab, A.1    Al-Saghir, F.2    Alnabhan, N.3
  • 4
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • KRIVITSKI NM: Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 48:244-250, 1995
    • (1995) Kidney Int , vol.48 , pp. 244-250
    • Krivitski, N.M.1
  • 5
    • 0028354105 scopus 로고
    • Detection of hemodialysis access outlet stenosis by measuring outlet resistance
    • VAN STONE JC, JONES M, VAN STONE J: Detection of hemodialysis access outlet stenosis by measuring outlet resistance. Am J Kidney Dis 23:562-568, 1994
    • (1994) Am J Kidney Dis , vol.23 , pp. 562-568
    • Van Stone, J.C.1    Jones, M.2    Van Stone, J.3
  • 6
    • 0031238950 scopus 로고    scopus 로고
    • Detecting vascular access dysfunction
    • BESARAB A, LUBKOWSKI T, FRINAK S, et al: Detecting vascular access dysfunction. ASAIO J 43:M539-543, 1997
    • (1997) ASAIO J , vol.43
    • Besarab, A.1    Lubkowski, T.2    Frinak, S.3
  • 7
    • 0030874891 scopus 로고    scopus 로고
    • Pressure or flow recordings for the surveillance of hemodialysis grafts
    • BOSMAN PJ, BOEREBOOM FT, SMITS HF, et al: Pressure or flow recordings for the surveillance of hemodialysis grafts. Kidney Int 52:1084-1088, 1997
    • (1997) Kidney Int , vol.52 , pp. 1084-1088
    • Bosman, P.J.1    Boereboom, F.T.2    Smits, H.F.3
  • 8
    • 0035070047 scopus 로고    scopus 로고
    • Graft surveillance: Venous pressure, access flow, or the combination?
    • SMITS JH, VAN DER LINDEN J, HAGEN EC, et al: Graft surveillance: Venous pressure, access flow, or the combination? Kidney Int 59:1551-1558, 2001
    • (2001) Kidney Int , vol.59 , pp. 1551-1558
    • Smits, J.H.1    Van Der Linden, J.2    Hagen, E.C.3
  • 9
    • 0036119454 scopus 로고    scopus 로고
    • Extracorporeal pressure monitoring and the detection of vascular access stenosis
    • KLEINEKOFORT W, KRAEMER M, RODE C, WIZEMANN V: Extracorporeal pressure monitoring and the detection of vascular access stenosis. Int J Artif Organs 25:45-50, 2002
    • (2002) Int J Artif Organs , vol.25 , pp. 45-50
    • Kleinekofort, W.1    Kraemer, M.2    Rode, C.3    Wizemann, V.4
  • 10
    • 0034915942 scopus 로고    scopus 로고
    • Clinical performance characteristics of hemodialysis graft monitoring
    • MCDOUGAL G, AGARWAL R: Clinical performance characteristics of hemodialysis graft monitoring. Kidney Int 60:762-766, 2001
    • (2001) Kidney Int , vol.60 , pp. 762-766
    • Mcdougal, G.1    Agarwal, R.2
  • 11
    • 0036007328 scopus 로고    scopus 로고
    • Preventing vascular access dysfunction: Which policy to follow
    • BESARAB A: Preventing vascular access dysfunction: Which policy to follow. Blood Purif 20:26-35, 2002
    • (2002) Blood Purif , vol.20 , pp. 26-35
    • Besarab, A.1
  • 12
    • 0036787507 scopus 로고    scopus 로고
    • Dynamic venous access pressure ratio test for hemodialysis access monitoring
    • FRINAK S, ZASUWA G, DUNFEE T, et al: Dynamic venous access pressure ratio test for hemodialysis access monitoring. Am J Kidney Dis 40:760-768, 2002
    • (2002) Am J Kidney Dis , vol.40 , pp. 760-768
    • Frinak, S.1    Zasuwa, G.2    Dunfee, T.3
  • 13
    • 0036233043 scopus 로고    scopus 로고
    • Value of static venous pressure for predicting arteriovenous graft thrombosis
    • DEMBER LM, HOLMBERG EF, KAUFMAN JS: Value of static venous pressure for predicting arteriovenous graft thrombosis. Kidney Int 61:1899-1904, 2002
    • (2002) Kidney Int , vol.61 , pp. 1899-1904
    • Dember, L.M.1    Holmberg, E.F.2    Kaufman, J.S.3
  • 14
    • 10744228009 scopus 로고    scopus 로고
    • Physical examination versus normalized pressure ratio for predicting outcomes of hemodialysis access interventions
    • TREROTOLA SO, PONCE P, STAVROPOULOS SW, et al: Physical examination versus normalized pressure ratio for predicting outcomes of hemodialysis access interventions. J Vasc Interv Radiol 14:1387-1394, 2003
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 1387-1394
    • Trerotola, S.O.1    Ponce, P.2    Stavropoulos, S.W.3
  • 15
    • 0027393820 scopus 로고
    • Hemodynamics of failing dialysis grafts
    • SULLIVAN KL, BESARAB A, BONN J, et al: Hemodynamics of failing dialysis grafts. Radiology 186:867-872, 1993
    • (1993) Radiology , vol.186 , pp. 867-872
    • Sullivan, K.L.1    Besarab, A.2    Bonn, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.