Volumn 27, Issue 9, 2004, Pages 1221-1230

Far-field R wave oversensing in dual chamber pacemakers designed for atrial arrhythmia management: Effect of pacing site and lead tip to ring distance

Author keywords

Atrial tachyarrhythmia; Far field oversensing; Pacing site; Tip to ring distance

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CORONARY SINUS; DEVICE; DUAL CHAMBER PACEMAKER; FAR FIELD R WAVE OVERSENSING; FEMALE; FOLLOW UP; HEART ATRIUM ARRHYTHMIA; HEART ATRIUM PACEMAKER; HEART PACING; HUMAN; IMPLANTATION; LEAD TIP TO RING DISTANCE; MAJOR CLINICAL STUDY; MALE; PACEMAKER ELECTRODE; PROSPECTIVE STUDY; R WAVE; REMOTE SENSING; SUPRAVENTRICULAR TACHYCARDIA;

EID: 4644242644     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2004.00613.x     Document Type: Article
Times cited : (24)

References (18)
  • 1
    • 0033954059 scopus 로고    scopus 로고
    • Pacing to prevent atrial fibrillation
    • Gillis AM. Pacing to prevent atrial fibrillation. Cardiol Clin 2000; 18:25-36.
    • (2000) Cardiol Clin , vol.18 , pp. 25-36
    • Gillis, A.M.1
  • 2
    • 0037182729 scopus 로고    scopus 로고
    • Implantable devices for the treatment of atrial fibrillation
    • Cooper JM, Katcher MS, Orlov MV. Implantable devices for the treatment of atrial fibrillation. N Engl J Med 2002; 346:2062-2068.
    • (2002) N Engl J Med , vol.346 , pp. 2062-2068
    • Cooper, J.M.1    Katcher, M.S.2    Orlov, M.V.3
  • 3
    • 0032710593 scopus 로고    scopus 로고
    • Bipolar ventricular far-field signals in the atrium
    • Frohlig G, Helwani Z, Kusch O, et al. Bipolar ventricular far-field signals in the atrium. PACE 1999; 22:1604-1613.
    • (1999) PACE , vol.22 , pp. 1604-1613
    • Frohlig, G.1    Helwani, Z.2    Kusch, O.3
  • 4
    • 0030907244 scopus 로고    scopus 로고
    • Analysis of atrial sensed far-field ventricular signals: A reassessment
    • Brouwer J, Nagelkerke D, den Heijer P, et al. Analysis of atrial sensed far-field ventricular signals: A reassessment. PACE 1997; 20:916-922.
    • (1997) PACE , vol.20 , pp. 916-922
    • Brouwer, J.1    Nagelkerke, D.2    Den Heijer, P.3
  • 5
    • 0034888919 scopus 로고    scopus 로고
    • Far field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications
    • Weretka S, Becker R, Hilbel T, et al. Far field R wave oversensing in a dual chamber arrhythmia management device: Predisposing factors and practical implications. PACE 2001; 24:1240-1246.
    • (2001) PACE , vol.24 , pp. 1240-1246
    • Weretka, S.1    Becker, R.2    Hilbel, T.3
  • 6
    • 0031818491 scopus 로고    scopus 로고
    • Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far field R wave oversensing in a new dual chamber defibrillator
    • Wolpert C, Jung W, Scholl C, et al. Electrical proarrhythmia: Induction of inappropriate atrial therapies due to far field R wave oversensing in a new dual chamber defibrillator. J Cardiovasc Electrophysiol 1998; 9:859-863.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 859-863
    • Wolpert, C.1    Jung, W.2    Scholl, C.3
  • 7
    • 0035206475 scopus 로고    scopus 로고
    • Randomized crossover comparison of right atrial appendage pacing versus interatrial septum pacing for prevention of paroxysmal atrial fibrillation in patients with sinus bradycardia
    • Padeletti L, Pieragnoli P, Ciapetti C, et al. Randomized crossover comparison of right atrial appendage pacing versus interatrial septum pacing for prevention of paroxysmal atrial fibrillation in patients with sinus bradycardia. Am Heart J 2001; 142:1047-1055.
    • (2001) Am Heart J , vol.142 , pp. 1047-1055
    • Padeletti, L.1    Pieragnoli, P.2    Ciapetti, C.3
  • 8
    • 0034890875 scopus 로고    scopus 로고
    • Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: Results of a multicenter randomized trial
    • Bailin SJ, Adler S, Giudici M. Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: Results of a multicenter randomized trial. J Cardiovasc Electrophysiol 2001; 12:912-917.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 912-917
    • Bailin, S.J.1    Adler, S.2    Giudici, M.3
  • 9
    • 10744228309 scopus 로고    scopus 로고
    • Combined efficacy of atrial septal lead placement and atrial pacing algorithms for prevention of paroxysmal atrial tachyarrhythmia
    • Padeletti L, Purerfellner H, Adler S, et al. Combined efficacy of atrial septal lead placement and atrial pacing algorithms for prevention of paroxysmal atrial tachyarrhythmia. J Cardiovasc Electrophysiol 2003; 14:1189-1195.
    • (2003) J Cardiovasc Electrophysiol , vol.14 , pp. 1189-1195
    • Padeletti, L.1    Purerfellner, H.2    Adler, S.3
  • 10
    • 0001561110 scopus 로고    scopus 로고
    • Effect of different location of the atrial lead on the near-field and far-field electrocardiograms in dual chamber pacemakers defibrillators
    • Kantharia B, Wilbur S, Padder F, et al. Effect of different location of the atrial lead on the near-field and far-field electrocardiograms in dual chamber pacemakers defibrillators. PACE 1999; 22:824.
    • (1999) PACE , vol.22 , pp. 824
    • Kantharia, B.1    Wilbur, S.2    Padder, F.3
  • 11
    • 0000187305 scopus 로고    scopus 로고
    • Atrial lead position affects far-field R-wave oversensing for rate responsive dual chamber implantable cardioverter defibrillators
    • Williamson BD, Baker JH II, Bartelt NJ, et al. Atrial lead position affects far-field R-wave oversensing for rate responsive dual chamber implantable cardioverter defibrillators. PACE 1999; 22:849.
    • (1999) PACE , vol.22 , pp. 849
    • Williamson, B.D.1    Baker II, J.H.2    Bartelt, N.J.3
  • 12
    • 0032492742 scopus 로고    scopus 로고
    • ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive Summary - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation)
    • Gregoratos G, Cheitlin MD, Conill A, et al. ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive Summary - a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). Circulation 1998; 97:1325-1335.
    • (1998) Circulation , vol.97 , pp. 1325-1335
    • Gregoratos, G.1    Cheitlin, M.D.2    Conill, A.3
  • 13
    • 0034770736 scopus 로고    scopus 로고
    • Pace-termination and pacing for prevention of atrial tachyarrhythmias: Results from a multicenterstudy with an implantable device for atrial therapy
    • Israel CW, Hugl B, Unterberg C, et al. Pace-termination and pacing for prevention of atrial tachyarrhythmias: Results from a multicenterstudy with an implantable device for atrial therapy. J Cardiovasc Electrophysiol 2001; 12:1121-1128.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 1121-1128
    • Israel, C.W.1    Hugl, B.2    Unterberg, C.3
  • 14
    • 0034910437 scopus 로고    scopus 로고
    • Prevalence, characteristics and clinical implications of regular atrial tachyarrhythmias in patients with atrial fibrillation: Insights from a study using a new implantable device
    • Israel CW, Ehrlich JR, Gronefeld G, et al. Prevalence, characteristics and clinical implications of regular atrial tachyarrhythmias in patients with atrial fibrillation: Insights from a study using a new implantable device. J Am Coll Cardiol 2001; 38:355-363.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 355-363
    • Israel, C.W.1    Ehrlich, J.R.2    Gronefeld, G.3
  • 15
    • 0343775801 scopus 로고    scopus 로고
    • Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator
    • For the Worldwide Jewel AF Investigators
    • Swerdlow CD, Schoels W, Dijkman B, et al. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter- defibrillator. For the Worldwide Jewel AF Investigators. Circulation 2000; 101:878-885.
    • (2000) Circulation , vol.101 , pp. 878-885
    • Swerdlow, C.D.1    Schoels, W.2    Dijkman, B.3
  • 16
    • 0035936534 scopus 로고    scopus 로고
    • Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection: Results and technical considerations
    • Wilkoff BL, Kuhlkamp V, Volosin K, et al. Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection: Results and technical considerations. Circulation 2001; 23:103:381-386.
    • (2001) Circulation , vol.23 , Issue.103 , pp. 381-386
    • Wilkoff, B.L.1    Kuhlkamp, V.2    Volosin, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.