메뉴 건너뛰기




Volumn 39, Issue 6, 2008, Pages 1894-1897

Assessment of intracranial collateral flow by using dynamic arterial spin labeling mra and transcranial color-coded duplex ultrasound

Author keywords

Carotid stenosis; Collateral circulation; Diagnostic imaging; Magnetic resonance angiography; Transcranial ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN BLOOD FLOW; CLINICAL ARTICLE; COLLATERAL CIRCULATION; DOPPLER ECHOGRAPHY; DYNAMIC ANGIOGRAPHY; FEMALE; FUNCTIONAL ASSESSMENT; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; INTERNAL CAROTID ARTERY OCCLUSION; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; PATHOLOGICAL ANATOMY; PRIORITY JOURNAL; SENSITIVITY ANALYSIS; SPIN LABELING; STROKE; TIME OF FLIGHT MAGNETIC RESONANCE ANGIOGRAPHY; TRANSCRANIAL COLOR CODED DUPLEX ECHOGRAPHY; TRANSIENT ISCHEMIC ATTACK; BRAIN; BRAIN ARTERY; BRAIN CIRCULATION; BRAIN ISCHEMIA; CAROTID ARTERY OBSTRUCTION; COMPARATIVE STUDY; ECHOGRAPHY; EVALUATION; HISTOLOGY; METHODOLOGY; MIDDLE AGED; PATHOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY; PREDICTION AND FORECASTING; PROSPECTIVE STUDY; VASCULARIZATION;

EID: 46249130597     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/STROKEAHA.107.503482     Document Type: Article
Times cited : (40)

References (12)
  • 1
    • 27944447653 scopus 로고    scopus 로고
    • The discovery of encephalic arteries. From Johann Jacob Wepfer to Charles Foix
    • Tatu L, Moulin T, Monnier G. The discovery of encephalic arteries. From Johann Jacob Wepfer to Charles Foix. Cerebrovasc Dis. 2005;20: 427-432.
    • (2005) Cerebrovasc Dis , vol.20 , pp. 427-432
    • Tatu, L.1    Moulin, T.2    Monnier, G.3
  • 2
    • 2342562447 scopus 로고
    • 1675), the founder of clinical neuro-science
    • Molnar Z. Thomas Willis (1621-1675), the founder of clinical neuro-science. Nat Rev Neurosci. 2004;5:329-335.
    • (1621) Nat Rev Neurosci , vol.2004 , Issue.5 , pp. 329-335
    • Molnar, Z.1    Willis, T.2
  • 3
    • 0033971337 scopus 로고    scopus 로고
    • Angio-graphically defined collateral circulation and risk of stroke patients with severe carotid artery stenosis
    • Henderson RD, Eliasziw M, Fox AJ, Rothwell PM, Barnett HJM. Angio-graphically defined collateral circulation and risk of stroke patients with severe carotid artery stenosis. Stroke. 2000;31:128 -132.
    • (2000) Stroke , vol.31 , pp. 128-132
    • Henderson, R.D.1    Eliasziw, M.2    Fox, A.J.3    Rothwell, P.M.4    Barnett, H.J.M.5
  • 4
    • 0035214916 scopus 로고    scopus 로고
    • Collateral ability of the circle of Willis in patients with unilateral internal carotid artery occlusion-Border zone infarcts and clinical symptoms
    • Hendrikse J, Hartkamp MJ, Hillen B, Mali WPTM, van der Grond J. Collateral ability of the circle of Willis in patients with unilateral internal carotid artery occlusion-Border zone infarcts and clinical symptoms. Stroke. 2001;32:2768-2773.
    • (2001) Stroke , vol.32 , pp. 2768-2773
    • Hendrikse, J.1    Hartkamp, M.J.2    Hillen, B.3    Mali, W.P.T.M.4    van der Grond, J.5
  • 5
    • 0042919302 scopus 로고    scopus 로고
    • Collateral circulation
    • Liebeskind DS. Collateral circulation. Stroke. 2003;34:2279-2284.
    • (2003) Stroke , vol.34 , pp. 2279-2284
    • Liebeskind, D.S.1
  • 7
    • 0034757715 scopus 로고    scopus 로고
    • Arterial spin labeling in combination with a look-locker sampling strategy: Inflow turbo-sampling EPI-FAIR (ITS-FAIR)
    • Günther M, Bock M, Schad LR. Arterial spin labeling in combination with a look-locker sampling strategy: inflow turbo-sampling EPI-FAIR (ITS-FAIR). Magn Reson Med. 2001;46:974-984.
    • (2001) Magn Reson Med , vol.46 , pp. 974-984
    • Günther, M.1    Bock, M.2    Schad, L.R.3
  • 9
    • 0031015618 scopus 로고    scopus 로고
    • Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis
    • Baumgartner RW, Baumgartner I, Mattle HP, Schroth G. Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis. AJNR Am J Neuroradiol. 1997;18:127-133.
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 127-133
    • Baumgartner, R.W.1    Baumgartner, I.2    Mattle, H.P.3    Schroth, G.4
  • 10
    • 0344405732 scopus 로고    scopus 로고
    • Assessment of the collateral function of the circle of Willis: Three dimensional time-of-flight MRA compared with transcranial color-coded duplex sonography
    • Hoksbergen AW, Majoie CB, Hulsmans FJ, Legemate DA. Assessment of the collateral function of the circle of Willis: Three dimensional time-of-flight MRA compared with transcranial color-coded duplex sonography. AJNR Am J Neuroradiol. 2003;24:456-462.
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 456-462
    • Hoksbergen, A.W.1    Majoie, C.B.2    Hulsmans, F.J.3    Legemate, D.A.4
  • 12
    • 66949146712 scopus 로고    scopus 로고
    • Correlation of dynamic MRA with flow velocity on TCD sonography in normal controls and patients with internal carotid artery stenosis
    • Griebe M, Szabo K, Guenther M, Kern R, Sedlaczek O, Hennerici M, Gass A. Correlation of dynamic MRA with flow velocity on TCD sonography in normal controls and patients with internal carotid artery stenosis. Cerebrovasc Dis. 2005;19(Suppl 2):152.
    • (2005) Cerebrovasc Dis , vol.19 , Issue.SUPPL. 2 , pp. 152
    • Griebe, M.1    Szabo, K.2    Guenther, M.3    Kern, R.4    Sedlaczek, O.5    Hennerici, M.6    Gass, A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.