메뉴 건너뛰기




Volumn 15, Issue 5, 2008, Pages 891-892

Prevention of assay interference in infectious-disease serology tests done on the liaison platform

Author keywords

[No Author keywords available]

Indexed keywords

IMMUNOGLOBULIN M ANTIBODY; POLYVINYL ALCOHOL; POVIDONE; IMMUNOGLOBULIN M; VIRUS ANTIBODY;

EID: 46249113845     PISSN: 15566811     EISSN: 1556679X     Source Type: Journal    
DOI: 10.1128/CVI.00012-08     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0035499104 scopus 로고    scopus 로고
    • Resistance to nonspecific protein adsorption by poly(vinyl alcohol) thin films adsorbed to a poly(styrene) support matrix using surface plasmon resonance
    • Barrett, D. A., M. S. Hartshome, M. A. Hussain, P. N. Shaw, and M. C. Davies. 2001. Resistance to nonspecific protein adsorption by poly(vinyl alcohol) thin films adsorbed to a poly(styrene) support matrix using surface plasmon resonance. Anal. Chem. 73:5232-5239.
    • (2001) Anal. Chem , vol.73 , pp. 5232-5239
    • Barrett, D.A.1    Hartshome, M.S.2    Hussain, M.A.3    Shaw, P.N.4    Davies, M.C.5
  • 3
    • 35748975971 scopus 로고    scopus 로고
    • False positive PTH results: An easy strategy to test and detect analytical interferences in routine practice
    • Cavalier, E., A. Carlisi, J. P. Chapelle, and P. Delanaye. 2008. False positive PTH results: an easy strategy to test and detect analytical interferences in routine practice. Clin. Chim. Acta 387:150-152.
    • (2008) Clin. Chim. Acta , vol.387 , pp. 150-152
    • Cavalier, E.1    Carlisi, A.2    Chapelle, J.P.3    Delanaye, P.4
  • 4
    • 14644391451 scopus 로고    scopus 로고
    • Serological diagnosis of infectious mononucleosis by chemiluminescent immunoassay using capsid antigen p18 of Epstein-Barr virus
    • Feng, Z., Z. Li, B. Sui, G. Xu, and T. Xia. 2005. Serological diagnosis of infectious mononucleosis by chemiluminescent immunoassay using capsid antigen p18 of Epstein-Barr virus. Clin. Chim. Acta 354:77-82.
    • (2005) Clin. Chim. Acta , vol.354 , pp. 77-82
    • Feng, Z.1    Li, Z.2    Sui, B.3    Xu, G.4    Xia, T.5
  • 5
    • 33746837662 scopus 로고    scopus 로고
    • Analysis of human sera that are polyreactive in an addressable laser bead immunoassay
    • Fritzler, M. J., F. Behmanesh, and M. L. Fritzler. 2006. Analysis of human sera that are polyreactive in an addressable laser bead immunoassay. Clin. Immunol. 120:349-356.
    • (2006) Clin. Immunol , vol.120 , pp. 349-356
    • Fritzler, M.J.1    Behmanesh, F.2    Fritzler, M.L.3
  • 6
    • 0027464867 scopus 로고
    • Polyvinylpyrrolidone as a blocking agent in immunochemical studies
    • Haycock, J. W. 1993. Polyvinylpyrrolidone as a blocking agent in immunochemical studies. Anal. Biochem. 208:397-399.
    • (1993) Anal. Biochem , vol.208 , pp. 397-399
    • Haycock, J.W.1
  • 7
    • 11144252247 scopus 로고    scopus 로고
    • A radical approach is needed to eliminate interference from endogenous antibodies in immunoassays
    • Ismail, A. A. 2005. A radical approach is needed to eliminate interference from endogenous antibodies in immunoassays. Clin. Chem. 51:25-26.
    • (2005) Clin. Chem , vol.51 , pp. 25-26
    • Ismail, A.A.1
  • 8
    • 16844368034 scopus 로고    scopus 로고
    • European multicenter study of the LIAISON automated diagnostic system for determination of Toxoplasma gondii-specific immunoglobulin G (IgG) and IgM and the IgG avidity index
    • Petersen, E., M. V. Borobio, E. Guy, O. Liesenfeld, V. Meroni, A. Naessens, E. Spranzi, and P. Thulliez. 2005. European multicenter study of the LIAISON automated diagnostic system for determination of Toxoplasma gondii-specific immunoglobulin G (IgG) and IgM and the IgG avidity index. J. Clin. Microbiol. 43:1570-1574.
    • (2005) J. Clin. Microbiol , vol.43 , pp. 1570-1574
    • Petersen, E.1    Borobio, M.V.2    Guy, E.3    Liesenfeld, O.4    Meroni, V.5    Naessens, A.6    Spranzi, E.7    Thulliez, P.8
  • 9
    • 0031877466 scopus 로고    scopus 로고
    • Interferences with two-site immunoassays by human anti-mouse antibodies formed by patients treated with monoclonal antibodies: Comparison of different blocking reagents
    • Reinsberg, J. 1998. Interferences with two-site immunoassays by human anti-mouse antibodies formed by patients treated with monoclonal antibodies: comparison of different blocking reagents. Clin. Chem. 44:1742-1744.
    • (1998) Clin. Chem , vol.44 , pp. 1742-1744
    • Reinsberg, J.1
  • 10
    • 0028113786 scopus 로고
    • Poly(vinyl alcohol) as a blocking agent in enzyme immunoassays
    • Rodda, D. J., and H. Yamazaki. 1994. Poly(vinyl alcohol) as a blocking agent in enzyme immunoassays. Immunol. Investig. 23:421-428.
    • (1994) Immunol. Investig , vol.23 , pp. 421-428
    • Rodda, D.J.1    Yamazaki, H.2
  • 12
    • 31944441629 scopus 로고    scopus 로고
    • Suppression of non-specific binding in serological Luminex assays
    • Waterboer, T., P. Sehr, and M. Pawlita. 2006. Suppression of non-specific binding in serological Luminex assays. J. Immunol. Methods 309:200-204.
    • (2006) J. Immunol. Methods , vol.309 , pp. 200-204
    • Waterboer, T.1    Sehr, P.2    Pawlita, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.