메뉴 건너뛰기




Volumn 33, Issue 3, 2008, Pages 363-368

Keeping osteocytes alive: A comparison of drilling and hammering k-wires into bone

Author keywords

Animal; Histology; Insertion technique; K wire; Pneumatic hammer

Indexed keywords

ANIMAL CELL; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; BONE NECROSIS; CALLUS; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; CORTICAL BONE; DRILL; FEMALE; FEMUR; FRACTURE; HINDLIMB; HISTOPATHOLOGY; INTERMETHOD COMPARISON; KIRSCHNER WIRE; NONHUMAN; OPERATION DURATION; OSTEOCYTE; POSTOPERATIVE HEMORRHAGE; RABBIT; SURGICAL INSTRUMENT; TIBIA;

EID: 46249088947     PISSN: 17531934     EISSN: None     Source Type: Journal    
DOI: 10.1177/1753193408087104     Document Type: Article
Times cited : (15)

References (25)
  • 6
    • 0034446654 scopus 로고    scopus 로고
    • The effects of drilling force on cortical temperatures and their duration: An in vitro study
    • Bachus, KN, MT Rondina, and DT Hutchinson (2000). The effects of drilling force on cortical temperatures and their duration: An in vitro study. Medical Engineering & Physics, 22, 685-691.
    • (2000) Medical Engineering & Physics , vol.22 , pp. 685-691
    • Bachus, K.N.1    Rondina, M.T.2    Hutchinson, D.T.3
  • 9
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: Vital-microscopic study in the rabbit
    • Eriksson, AR, and T Albrektsson (1983). Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit. The Journal of Prosthetic Dentistry, 50, 101-107.
    • (1983) The Journal of Prosthetic Dentistry , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 10
    • 0021704071 scopus 로고
    • Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals
    • Eriksson, AR, T Albrektsson, and B Albrektsson (1984a). Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals. Acta Orthopaedica Scandinavica, 55, 629-631.
    • (1984) Acta Orthopaedica Scandinavica , vol.55 , pp. 629-631
    • Eriksson, A.R.1    Albrektsson, T.2    Albrektsson, B.3
  • 11
    • 0021712493 scopus 로고
    • Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit
    • Eriksson, RA, T Albrektsson, and B Magnusson (1984b). Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit. Scandinavian Journal of Plastic and Reconstructive Surgery, 18, 261-268.
    • (1984) Scandinavian Journal of Plastic and Reconstructive Surgery , vol.18 , pp. 261-268
    • Eriksson, R.A.1    Albrektsson, T.2    Magnusson, B.3
  • 12
    • 0030755804 scopus 로고    scopus 로고
    • The risks of Kirschner wire placement in the distal radius: A comparison of techniques
    • Hochwald, NL, R Levine, and III Tornetta (1997). The risks of Kirschner wire placement in the distal radius: A comparison of techniques. The Journal of Hand Surgery, 22A, 580-584.
    • (1997) The Journal of Hand Surgery , vol.22 A , pp. 580-584
    • Hochwald, N.L.1    Levine, R.2    Tornetta, I.I.I.3
  • 13
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews, LS, and C Hirsch (1972). Temperatures measured in human cortical bone when drilling. The Journal of Bone and Joint Surgery, 54A, 297-308.
    • (1972) The Journal of Bone and Joint Surgery , vol.54 A , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 17
    • 0036150972 scopus 로고    scopus 로고
    • Drilling efficiency and temperature elevation of three types of Kirschner-wire point
    • Piska, M, L Yang, M Reed, and M Saleh (2002). Drilling efficiency and temperature elevation of three types of Kirschner-wire point. The Journal of Bone and Joint Surgery, 84B, 137-140.
    • (2002) The Journal of Bone and Joint Surgery , vol.84 B , pp. 137-140
    • Piska, M.1    Yang, L.2    Reed, M.3    Saleh, M.4
  • 18
    • 0031152012 scopus 로고    scopus 로고
    • Influence of different parameters on bone heating and drilling time in implantology
    • Reingewirtz, Y, S Szmukler-Moncler, and B Senger (1997). Influence of different parameters on bone heating and drilling time in implantology. Clinical Oral Implants Research, 8, 189-197.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 189-197
    • Reingewirtz, Y.1    Szmukler-Moncler, S.2    Senger, B.3
  • 19
    • 0020595207 scopus 로고
    • The person behind the name: Martin Kirschner
    • Romm, S (1983). The person behind the name: Martin Kirschner. Plastic and Reconstructive Surgery, 72, 104-107.
    • (1983) Plastic and Reconstructive Surgery , vol.72 , pp. 104-107
    • Romm, S.1
  • 20
    • 0028870063 scopus 로고
    • Percutaneous Kirschner wire fixation through the snuff box: An anatomic study
    • Steinberg, BD, KD Plancher, and RS Idler (1995). Percutaneous Kirschner wire fixation through the snuff box: An anatomic study. The Journal of Hand Surgery, 20A, 57-62.
    • (1995) The Journal of Hand Surgery , vol.20 A , pp. 57-62
    • Steinberg, B.D.1    Plancher, K.D.2    Idler, R.S.3
  • 23
    • 0025874485 scopus 로고
    • Increase of temperature during osteotomy. In vitro and in vivo investigations
    • Wachter, R, and P Stoll (1991). Increase of temperature during osteotomy. In vitro and in vivo investigations. International Journal of Oral Maxillofacial Surgery, 20, 245-249.
    • (1991) International Journal of Oral Maxillofacial Surgery , vol.20 , pp. 245-249
    • Wachter, P.1    Stoll, R.2
  • 25
    • 0027485411 scopus 로고
    • Insertion of K-wires by hammer generates less heat. A study of drilling and hammering K-wires into bone
    • Zegunis, V, S Toksvig-Larsen, and R Tikuisis (1993). Insertion of K-wires by hammer generates less heat. A study of drilling and hammering K-wires into bone. Acta Orthopaedica Scandinavica, 64, 592-594.
    • (1993) Acta Orthopaedica Scandinavica , vol.64 , pp. 592-594
    • Zegunis, V.1    Toksvig-Larsen, S.2    Tikuisis, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.