메뉴 건너뛰기




Volumn 54, Issue 3, 2008, Pages 235-254

Dynamics of a closed-loop thermosyphon incorporating thermal storage

Author keywords

[No Author keywords available]

Indexed keywords

BUOYANCY; CAPILLARY FLOW; ELECTRIC CHARGE; FLUID MECHANICS; HEAT STORAGE; LITHIUM BATTERIES; SIPHONS; STORAGE (MATERIALS);

EID: 46149084476     PISSN: 10407782     EISSN: 15210634     Source Type: Journal    
DOI: 10.1080/10407780802084553     Document Type: Article
Times cited : (13)

References (26)
  • 1
    • 0024108444 scopus 로고
    • Natural Circulation Loops
    • R. Grief, Natural Circulation Loops, ASME J. Heat Transfer, vol. 110, pp. 1243-1258, 1988.
    • (1988) ASME J. Heat Transfer , vol.110 , pp. 1243-1258
    • Grief, R.1
  • 3
    • 0018545850 scopus 로고
    • Open-Loop Thermosyphons with Geological Applications
    • K. E. Torrance, Open-Loop Thermosyphons with Geological Applications, ASME J. Heat Transfer, vol. 101, pp. 677-683, 1979.
    • (1979) ASME J. Heat Transfer , vol.101 , pp. 677-683
    • Torrance, K.E.1
  • 4
    • 0019050516 scopus 로고
    • Heat Transfer by a Free Convection Loop Embedded in a Heat-Conducting Solid
    • K. E. Torrance and V. W. C. Chan, Heat Transfer by a Free Convection Loop Embedded in a Heat-Conducting Solid, Int. J. Heat Mass Transfer, vol. 23, pp. 1091-1097, 1980.
    • (1980) Int. J. Heat Mass Transfer , vol.23 , pp. 1091-1097
    • Torrance, K.E.1    Chan, V.W.C.2
  • 5
    • 0019602007 scopus 로고
    • On the Stability and Flow Reversal of an Asymmetrically Heated Open Convection Loop
    • H. H. Bau and K. E. Torrance, On the Stability and Flow Reversal of an Asymmetrically Heated Open Convection Loop, J. of Fluid Mech., vol. 106, pp. 417-433, 1981.
    • (1981) J. of Fluid Mech , vol.106 , pp. 417-433
    • Bau, H.H.1    Torrance, K.E.2
  • 6
    • 0016432011 scopus 로고
    • Stability Characteristics of a Single-Phase Free Convection Loop
    • H. F. Creveling, J. F. DePaz, J. Y. Baladi, and R. J. Schoenhals, Stability Characteristics of a Single-Phase Free Convection Loop, J. of Fluid Mech., vol. 67, pp. 65-84, 1975.
    • (1975) J. of Fluid Mech , vol.67 , pp. 65-84
    • Creveling, H.F.1    DePaz, J.F.2    Baladi, J.Y.3    Schoenhals, R.J.4
  • 7
    • 0018546721 scopus 로고
    • The Transient and Stability Behavior of a Natural Convection Loop
    • R. Grief, Y. Zvirin, and A. Mertol, The Transient and Stability Behavior of a Natural Convection Loop, ASME J. Heat Transfer, vol. 101, pp. 684-688, 1979.
    • (1979) ASME J. Heat Transfer , vol.101 , pp. 684-688
    • Grief, R.1    Zvirin, Y.2    Mertol, A.3
  • 8
    • 0018547003 scopus 로고
    • Flow in a Toroidal Thermosyphon with Angular Displacement of Heated and Cooled Sections
    • P. Damerell and R. J. Schoenhals, Flow in a Toroidal Thermosyphon with Angular Displacement of Heated and Cooled Sections, ASME J. Heat Transfer, vol. 101, pp. 672-676, 1979.
    • (1979) ASME J. Heat Transfer , vol.101 , pp. 672-676
    • Damerell, P.1    Schoenhals, R.J.2
  • 9
    • 0021818043 scopus 로고
    • The Toroidal Thermosyphon with Known Heat Flux
    • M. Sen, E. Ramos, and C. Trevino, The Toroidal Thermosyphon with Known Heat Flux, Int. J. Heat Mass Transfer, vol. 28, pp. 219-233, 1985.
    • (1985) Int. J. Heat Mass Transfer , vol.28 , pp. 219-233
    • Sen, M.1    Ramos, E.2    Trevino, C.3
  • 10
    • 0000830726 scopus 로고    scopus 로고
    • Optimal and Adaptive Control of Chaotic Convection -Theory and Experiments
    • P. K. Yuen and H. H. Bau, Optimal and Adaptive Control of Chaotic Convection -Theory and Experiments, Phys. Fluids, vol. 11, pp. 1435-1448, 1999.
    • (1999) Phys. Fluids , vol.11 , pp. 1435-1448
    • Yuen, P.K.1    Bau, H.H.2
  • 11
    • 0037374945 scopus 로고    scopus 로고
    • Modeling and Control of a Natural Circulation Loop
    • G. Muscato and M. Xibilia, Modeling and Control of a Natural Circulation Loop, J. Process Control, vol. 13, pp. 239-251, 2003.
    • (2003) J. Process Control , vol.13 , pp. 239-251
    • Muscato, G.1    Xibilia, M.2
  • 12
    • 0030407383 scopus 로고    scopus 로고
    • A Systematic Approach to Improving Thermosyphon SDHW Model Performance
    • ASME Solar Energy Division Conf, pp
    • T. N. Swift, J. A. Miller, and D. C. Hittle, A Systematic Approach to Improving Thermosyphon SDHW Model Performance, in Solar Engineering 1996, Proc. ASME Solar Energy Division Conf., pp. 165-171, 1996.
    • (1996) Solar Engineering 1996, Proc , pp. 165-171
    • Swift, T.N.1    Miller, J.A.2    Hittle, D.C.3
  • 13
    • 0346956915 scopus 로고    scopus 로고
    • Using an Ersatz Thermosiphon Loop to Model Natural Convection Flows inside a Shallow Enclosure
    • J. D. Burch and K. M. Gawlik, Using an Ersatz Thermosiphon Loop to Model Natural Convection Flows inside a Shallow Enclosure, in Proc. Solar 2001, pp. 183-190, 2001.
    • (2001) Proc. Solar , pp. 183-190
    • Burch, J.D.1    Gawlik, K.M.2
  • 14
    • 0019703819 scopus 로고
    • Detailed Loop Model Analysis of Liquid Solar Thermosyphons with Heat Exchangers
    • A. Mertol, W. Place, T. Webster, and R. Greif, Detailed Loop Model Analysis of Liquid Solar Thermosyphons with Heat Exchangers, Solar Energy, vol. 27, pp. 367-386, 1981.
    • (1981) Solar Energy , vol.27 , pp. 367-386
    • Mertol, A.1    Place, W.2    Webster, T.3    Greif, R.4
  • 15
    • 0032206926 scopus 로고    scopus 로고
    • Mixed Convection Heat Transfer and Pressure Drop Correlations for Tube-in-Shell Thermosyphon Heat Exchangers with Uniform Heat Flux
    • S. D. Dahl and J. H. Davidson, Mixed Convection Heat Transfer and Pressure Drop Correlations for Tube-in-Shell Thermosyphon Heat Exchangers with Uniform Heat Flux, ASME J. Solar Energy Eng., vol. 120, pp. 260-269, 1998.
    • (1998) ASME J. Solar Energy Eng , vol.120 , pp. 260-269
    • Dahl, S.D.1    Davidson, J.H.2
  • 16
    • 0032648315 scopus 로고    scopus 로고
    • Applicability of Uniform Heat Flux Nusselt Number Correlations to Thermosyphon Heat Exchangers for Solar Water Heaters
    • S. D. Dahl and J. H. Davidson, Applicability of Uniform Heat Flux Nusselt Number Correlations to Thermosyphon Heat Exchangers for Solar Water Heaters, ASME J. Solar Energy Eng., vol. 121, pp. 85-90, 1999.
    • (1999) ASME J. Solar Energy Eng , vol.121 , pp. 85-90
    • Dahl, S.D.1    Davidson, J.H.2
  • 17
    • 0021788043 scopus 로고
    • System Modeling and Operation Characteristics of Thermosyphon Solar Water Heaters
    • G. L. Morrison and J. E. Braun, System Modeling and Operation Characteristics of Thermosyphon Solar Water Heaters, Solar Energy, vol. 34, pp. 389-405, 1985.
    • (1985) Solar Energy , vol.34 , pp. 389-405
    • Morrison, G.L.1    Braun, J.E.2
  • 19
    • 0346753495 scopus 로고    scopus 로고
    • Thermodynamic Optimization of System Configuration for Electric Water Heating with Storage: Fully-Mixed Store
    • K. O. Homan, Thermodynamic Optimization of System Configuration for Electric Water Heating with Storage: Fully-Mixed Store, in Proc. of the ASME Advanced Energy Systems Division, pp. 479-491, 2001.
    • (2001) Proc. of the ASME Advanced Energy Systems Division , pp. 479-491
    • Homan, K.O.1
  • 20
    • 33645672456 scopus 로고    scopus 로고
    • Transient and Rate-Dependent Performance of Conventional Electric Storage Water Heating Systems
    • J. W. McMenamy and K. O. Homan, Transient and Rate-Dependent Performance of Conventional Electric Storage Water Heating Systems, ASME J. Solar Energy Eng., vol. 128, pp. 90-97, 2006.
    • (2006) ASME J. Solar Energy Eng , vol.128 , pp. 90-97
    • McMenamy, J.W.1    Homan, K.O.2
  • 22
    • 46149095057 scopus 로고    scopus 로고
    • K. O. Homan, Internal Small Storage Water Heater, U.S. 7,114,468 B1, 2006.
    • K. O. Homan, Internal Small Volume Storage Water Heater, U.S. 7,114,468 B1, 2006.
  • 24
    • 49449129017 scopus 로고
    • Towards the Ultimate Conservative Difference Scheme. IV. A New Approach to Numerical Convection
    • B. van Leer, Towards the Ultimate Conservative Difference Scheme. IV. A New Approach to Numerical Convection, J. of Comput. Phys., vol. 23, pp. 276-299, 1977.
    • (1977) J. of Comput. Phys , vol.23 , pp. 276-299
    • van Leer, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.