Volumn 8, Issue 4, 2008, Pages 563-569

Autograft containment in posterolateral spine fusion

Author keywords

Bioabsorbable implant; Graft containment; Intertransverse lumbar spine fusion

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; AUTOGRAFT; BIOCOMPATIBILITY; BIODEGRADABLE IMPLANT; BONE GRAFT; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DEVICE; HISTOPATHOLOGY; INFLAMMATION; LYMPHOCYTIC INFILTRATION; MALE; NONHUMAN; PRIORITY JOURNAL; RABBIT; SPINE FUSION; SPINE RADIOGRAPHY;

EID: 46049105535     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2007.04.017     Document Type: Article
Times cited : (8)

References (29)
  • 1
    • 0031573532 scopus 로고    scopus 로고
    • 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation
    • Fischgrund J.S., Mackay M., Herkowitz H.N., Brower R., Montgomery D.M., and Kurz L.T. 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation. Spine 22 24 (1997) 2807-2812
    • (1997) Spine , vol.22 , Issue.24 , pp. 2807-2812
    • Fischgrund, J.S.1    Mackay, M.2    Herkowitz, H.N.3    Brower, R.4    Montgomery, D.M.5    Kurz, L.T.6
  • 2
    • 1642476151 scopus 로고    scopus 로고
    • Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective long-term study comparing fusion and pseudarthrosis
    • discussion 33-4
    • Kornblum M.B., Fischgrund J.S., Herkowitz H.N., Abraham D.A., Berkower D.L., and Ditkoff J.S. Degenerative lumbar spondylolisthesis with spinal stenosis: a prospective long-term study comparing fusion and pseudarthrosis. Spine 29 7 (2004) 726-733 discussion 33-4
    • (2004) Spine , vol.29 , Issue.7 , pp. 726-733
    • Kornblum, M.B.1    Fischgrund, J.S.2    Herkowitz, H.N.3    Abraham, D.A.4    Berkower, D.L.5    Ditkoff, J.S.6
  • 3
    • 0026658355 scopus 로고
    • Guided bone regeneration of cranial defects, using biodegradable barriers: an experimental pilot study in the rabbit
    • Lundgren D., Nyman S., Mathisen T., Isaksson S., and Klinge B. Guided bone regeneration of cranial defects, using biodegradable barriers: an experimental pilot study in the rabbit. J Craniomaxillofac Surg 20 6 (1992) 257-260
    • (1992) J Craniomaxillofac Surg , vol.20 , Issue.6 , pp. 257-260
    • Lundgren, D.1    Nyman, S.2    Mathisen, T.3    Isaksson, S.4    Klinge, B.5
  • 4
    • 0343069792 scopus 로고    scopus 로고
    • Posterolateral intertransverse process spinal arthrodesis with rhBMP-2 in a nonhuman primate: important lessons learned regarding dose, carrier, and safety
    • Martin Jr. G.J., Boden S.D., Marone M.A., Marone M.A., and Moskovitz P.A. Posterolateral intertransverse process spinal arthrodesis with rhBMP-2 in a nonhuman primate: important lessons learned regarding dose, carrier, and safety. J Spinal Disord 12 3 (1999) 179-186
    • (1999) J Spinal Disord , vol.12 , Issue.3 , pp. 179-186
    • Martin Jr., G.J.1    Boden, S.D.2    Marone, M.A.3    Marone, M.A.4    Moskovitz, P.A.5
  • 5
    • 0033105582 scopus 로고    scopus 로고
    • Volumetric change of the graft bone after intertransverse fusion
    • Kim K.W., Ha K.Y., Moon M.S., Kim Y.S., Kwon S.Y., and Woo Y.K. Volumetric change of the graft bone after intertransverse fusion. Spine 24 5 (1999) 428-433
    • (1999) Spine , vol.24 , Issue.5 , pp. 428-433
    • Kim, K.W.1    Ha, K.Y.2    Moon, M.S.3    Kim, Y.S.4    Kwon, S.Y.5    Woo, Y.K.6
  • 6
    • 0036830546 scopus 로고    scopus 로고
    • Resorbable posterolateral graft containment in a rabbit spinal fusion model
    • Poynton A.R., Zheng F., Tomin E., Lane J.M., and Cornwall G.B. Resorbable posterolateral graft containment in a rabbit spinal fusion model. J Neurosurg 97 4 Suppl (2002) 460-463
    • (2002) J Neurosurg , vol.97 , Issue.4 SUPPL , pp. 460-463
    • Poynton, A.R.1    Zheng, F.2    Tomin, E.3    Lane, J.M.4    Cornwall, G.B.5
  • 8
    • 0024760875 scopus 로고
    • Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis
    • Robb R.A., Hanson D.P., Karwoski R.A., Larson A.G., Workman F.L., and Stacy M.C. Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. Comput Med Imaging Graph 13 (1989) 433-454
    • (1989) Comput Med Imaging Graph , vol.13 , pp. 433-454
    • Robb, R.A.1    Hanson, D.P.2    Karwoski, R.A.3    Larson, A.G.4    Workman, F.L.5    Stacy, M.C.6
  • 9
    • 0035437715 scopus 로고    scopus 로고
    • The Biomedical Imaging Resource at Mayo Clinic
    • [guest editorial]
    • Robb R. The Biomedical Imaging Resource at Mayo Clinic. [guest editorial]. IEEE Trans Med Imaging 20 (2001) 854-867
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 854-867
    • Robb, R.1
  • 10
    • 0036830235 scopus 로고    scopus 로고
    • Use of a resorbable sheet in iliac crest reconstruction in a sheep model
    • Cornwall G.B., Wheeler D.L., Thomas K.A., Taylor W.R., and Turner A.S. Use of a resorbable sheet in iliac crest reconstruction in a sheep model. J Neurosurg 97 4 Suppl) (2002) 456-459
    • (2002) J Neurosurg , vol.97 , Issue.4 SUPPL. , pp. 456-459
    • Cornwall, G.B.1    Wheeler, D.L.2    Thomas, K.A.3    Taylor, W.R.4    Turner, A.S.5
  • 11
    • 0031759235 scopus 로고    scopus 로고
    • A reabsorbable tubular chamber for the treatment of large diaphyseal bone defects. Experimental study in rabbits
    • Giardino R., Fini M., Aldini N.N., et al. A reabsorbable tubular chamber for the treatment of large diaphyseal bone defects. Experimental study in rabbits. Int J Artif Organs 21 8 (1998) 473-482
    • (1998) Int J Artif Organs , vol.21 , Issue.8 , pp. 473-482
    • Giardino, R.1    Fini, M.2    Aldini, N.N.3
  • 13
    • 0033070171 scopus 로고    scopus 로고
    • Guided bone regeneration with barrier membranes-a clinical and radiographic follow-up study after 24 months
    • Lorenzoni M., Pertl C., Polansky R., and Wegscheider W. Guided bone regeneration with barrier membranes-a clinical and radiographic follow-up study after 24 months. Clin Oral Implants Res 10 1 (1999) 16-23
    • (1999) Clin Oral Implants Res , vol.10 , Issue.1 , pp. 16-23
    • Lorenzoni, M.1    Pertl, C.2    Polansky, R.3    Wegscheider, W.4
  • 14
    • 0036974956 scopus 로고    scopus 로고
    • Histological assessment of augmented jaw bone utilizing a new collagen barrier membrane compared to a standard barrier membrane to protect a granular bone substitute material
    • Friedmann A., Strietzel F.P., Maretzki B., Pitaru S., and Bernimoulin J.-P. Histological assessment of augmented jaw bone utilizing a new collagen barrier membrane compared to a standard barrier membrane to protect a granular bone substitute material. Clin Oral Implants Res 13 6 (2002) 587-594
    • (2002) Clin Oral Implants Res , vol.13 , Issue.6 , pp. 587-594
    • Friedmann, A.1    Strietzel, F.P.2    Maretzki, B.3    Pitaru, S.4    Bernimoulin, J.-P.5
  • 15
    • 0031151416 scopus 로고    scopus 로고
    • Guided bone regeneration around titanium implants: report of the treatment of 1,503 sites with clinical reentries
    • Fugazzotto P.A., Shanaman R., Manos T., and Shectman R. Guided bone regeneration around titanium implants: report of the treatment of 1,503 sites with clinical reentries. Int J Periodontics Restorative Dent 17 3 (1997) 292-299
    • (1997) Int J Periodontics Restorative Dent , vol.17 , Issue.3 , pp. 292-299
    • Fugazzotto, P.A.1    Shanaman, R.2    Manos, T.3    Shectman, R.4
  • 16
    • 0034583624 scopus 로고    scopus 로고
    • Zygomaticomaxillary fracture repair with resorbable plates and screws
    • Eppley B.L. Zygomaticomaxillary fracture repair with resorbable plates and screws. J Craniofac Surg 11 4 (2000) 377-385
    • (2000) J Craniofac Surg , vol.11 , Issue.4 , pp. 377-385
    • Eppley, B.L.1
  • 17
    • 0038051473 scopus 로고    scopus 로고
    • Adverse tissue reactions to bioabsorbable fixation devices
    • Bostman O.M., and Pihlajamaki H.K. Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res 371 (2000) 216-227
    • (2000) Clin Orthop Relat Res , vol.371 , pp. 216-227
    • Bostman, O.M.1    Pihlajamaki, H.K.2
  • 18
    • 0032763401 scopus 로고    scopus 로고
    • LactoSorb resorbable osteosynthesis after sagittal split osteotomy of the mandible: a 2-year follow-up
    • Westermark A. LactoSorb resorbable osteosynthesis after sagittal split osteotomy of the mandible: a 2-year follow-up. J Craniofac Surg 10 6 (1999) 519-522
    • (1999) J Craniofac Surg , vol.10 , Issue.6 , pp. 519-522
    • Westermark, A.1
  • 19
    • 0035165602 scopus 로고    scopus 로고
    • The fate of resorbable poly-l-lactic/polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery
    • Edwards R.C., Kiely K.D., and Eppley B.L. The fate of resorbable poly-l-lactic/polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery. J Oral Maxillofac Surg 59 1 (2001) 19-25
    • (2001) J Oral Maxillofac Surg , vol.59 , Issue.1 , pp. 19-25
    • Edwards, R.C.1    Kiely, K.D.2    Eppley, B.L.3
  • 20
    • 2342599622 scopus 로고    scopus 로고
    • Are there any complications with bioabsorbable fixation devices?: a 10 year review in orthognathic surgery
    • Laine P., Kontio R., Lindqvist C., and Suuronen R. Are there any complications with bioabsorbable fixation devices?: a 10 year review in orthognathic surgery. Int J Oral Maxillofac Surg 33 3 (2004) 240-244
    • (2004) Int J Oral Maxillofac Surg , vol.33 , Issue.3 , pp. 240-244
    • Laine, P.1    Kontio, R.2    Lindqvist, C.3    Suuronen, R.4
  • 21
    • 46049085359 scopus 로고    scopus 로고
    • Vaccaro A. Resorbable polymers-application in spine surgery. Paper presented at: Proceedings of the Annual Meeting of the AAOS; March 22-26, 2006; Chicago, IL; Spine symposium.
    • Vaccaro A. Resorbable polymers-application in spine surgery. Paper presented at: Proceedings of the Annual Meeting of the AAOS; March 22-26, 2006; Chicago, IL; Spine symposium.
  • 22
    • 0036803037 scopus 로고    scopus 로고
    • Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disk disruption
    • discussion s9
    • Vaccaro A.R., Venger B.H., Kelleher P.M., et al. Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disk disruption. Orthopedics 25 10 Suppl (2002) s1191-s1199 discussion s9
    • (2002) Orthopedics , vol.25 , Issue.10 SUPPL
    • Vaccaro, A.R.1    Venger, B.H.2    Kelleher, P.M.3
  • 23
    • 0036803055 scopus 로고    scopus 로고
    • Spinal applications of bioabsorbable implants
    • Vaccaro A.R., and Madigan L. Spinal applications of bioabsorbable implants. Orthopedics 25 10 Suppl (2002) s1115-s1120
    • (2002) Orthopedics , vol.25 , Issue.10 SUPPL
    • Vaccaro, A.R.1    Madigan, L.2
  • 24
    • 33644679368 scopus 로고    scopus 로고
    • Biomechanical analysis of a newly designed bioabsorbable anterior cervical plate. Invited submission from the joint section meeting on disorders of the spine and peripheral nerves, March 2005
    • Ames C.P., Acosta Jr. F.L., Chamberlain R.H., Larios A.E., and Crawford N.R. Biomechanical analysis of a newly designed bioabsorbable anterior cervical plate. Invited submission from the joint section meeting on disorders of the spine and peripheral nerves, March 2005. J Neurosurg Spine 3 6 (2005) 465-470
    • (2005) J Neurosurg Spine , vol.3 , Issue.6 , pp. 465-470
    • Ames, C.P.1    Acosta Jr., F.L.2    Chamberlain, R.H.3    Larios, A.E.4    Crawford, N.R.5
  • 28
    • 0032431428 scopus 로고    scopus 로고
    • Degradation of and intraosseous reactions to biodegradable poly-l-lactide screws: a study in minipigs
    • Fuchs M., Koster G., Krause T., Merten H.A., and Schmid A. Degradation of and intraosseous reactions to biodegradable poly-l-lactide screws: a study in minipigs. Arch Orthop Trauma Surg 118 3 (1998) 140-144
    • (1998) Arch Orthop Trauma Surg , vol.118 , Issue.3 , pp. 140-144
    • Fuchs, M.1    Koster, G.2    Krause, T.3    Merten, H.A.4    Schmid, A.5
  • 29
    • 33646440730 scopus 로고    scopus 로고
    • Paraspinal muscle vasculature contributes to posterolateral spinal fusion
    • Bawa M., Schimizzi A.L., Leek B., et al. Paraspinal muscle vasculature contributes to posterolateral spinal fusion. Spine 31 8 (2006) 891-896
    • (2006) Spine , vol.31 , Issue.8 , pp. 891-896
    • Bawa, M.1    Schimizzi, A.L.2    Leek, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.