-
1
-
-
33645341440
-
Anatomy-based inverse optimization in high-dose-rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer: comparison of incidence of acute genitourinary toxicity between anatomy-based inverse optimization and geometric optimization
-
Akimoto T., Katoh H., Kitamoto Y., Shirai K., Shioya M., and Nakano T. Anatomy-based inverse optimization in high-dose-rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer: comparison of incidence of acute genitourinary toxicity between anatomy-based inverse optimization and geometric optimization. Int J Radiat Oncol Biol Phys 64 (2006) 1360-1366
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.64
, pp. 1360-1366
-
-
Akimoto, T.1
Katoh, H.2
Kitamoto, Y.3
Shirai, K.4
Shioya, M.5
Nakano, T.6
-
2
-
-
14744292134
-
Long-term outcome of high dose rate brachytherapy in radiotherapy of localised prostate cancer
-
Astrom L., Pedersen D., Mercke C., Holmang S., and Johansson K.A. Long-term outcome of high dose rate brachytherapy in radiotherapy of localised prostate cancer. Radiother Oncol 74 (2005) 157-161
-
(2005)
Radiother Oncol
, vol.74
, pp. 157-161
-
-
Astrom, L.1
Pedersen, D.2
Mercke, C.3
Holmang, S.4
Johansson, K.A.5
-
3
-
-
20044381120
-
Inverse treatment planning based on MRI for HDR prostate brachytherapy
-
Citrin D., Ning H., Guion P., et al. Inverse treatment planning based on MRI for HDR prostate brachytherapy. Int J Radiat Oncol Biol Phys 61 (2005) 1267-1275
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.61
, pp. 1267-1275
-
-
Citrin, D.1
Ning, H.2
Guion, P.3
-
4
-
-
34548043496
-
Patterns of toxicity following high-dose-rate brachytherapy boost for prostate cancer: mature prospective phase I/II study results
-
Duchesne G.M., Williams S.G., Das R., and Tai K.H. Patterns of toxicity following high-dose-rate brachytherapy boost for prostate cancer: mature prospective phase I/II study results. Radiother Oncol 84 (2007) 128-134
-
(2007)
Radiother Oncol
, vol.84
, pp. 128-134
-
-
Duchesne, G.M.1
Williams, S.G.2
Das, R.3
Tai, K.H.4
-
5
-
-
8144226372
-
Comparison of inverse planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy
-
Hsu I.C., Lessard E., Weinberg V., and Pouliot J. Comparison of inverse planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy. Brachytherapy 3 (2004) 147-152
-
(2004)
Brachytherapy
, vol.3
, pp. 147-152
-
-
Hsu, I.C.1
Lessard, E.2
Weinberg, V.3
Pouliot, J.4
-
6
-
-
45849137778
-
-
Hsu IC, Shinohara K, Pouliot J, Purdy J, Michalski J, Ibbott GS. RTOG-0321 protocol: phase II trial of combined high dose rate brachytherapy and external beam radiotherapy for adenocarcinoma of the prostate. Rad Ther Oncol Group, Philadelphia 2004, http://www.rtog.org/.
-
Hsu IC, Shinohara K, Pouliot J, Purdy J, Michalski J, Ibbott GS. RTOG-0321 protocol: phase II trial of combined high dose rate brachytherapy and external beam radiotherapy for adenocarcinoma of the prostate. Rad Ther Oncol Group, Philadelphia 2004, http://www.rtog.org/.
-
-
-
-
7
-
-
16544370152
-
Prostate depiction at endorectal MR spectroscopic imaging: investigation of a standardized evaluation system
-
Jung J.A., Coakley F.V., Vigneron D.B., et al. Prostate depiction at endorectal MR spectroscopic imaging: investigation of a standardized evaluation system. Radiology 233 (2004) 701-708
-
(2004)
Radiology
, vol.233
, pp. 701-708
-
-
Jung, J.A.1
Coakley, F.V.2
Vigneron, D.B.3
-
9
-
-
3042522618
-
Dosimetric impact of prostate volume change between CT-based HDR brachytherapy fractions
-
Kim Y., Hsu I.C., Lessard E., Vujic J., and Pouliot J. Dosimetric impact of prostate volume change between CT-based HDR brachytherapy fractions. Int J Radiat Oncol Biol Phys 59 (2004) 1208-1216
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 1208-1216
-
-
Kim, Y.1
Hsu, I.C.2
Lessard, E.3
Vujic, J.4
Pouliot, J.5
-
10
-
-
38049120408
-
Cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer
-
Kim Y., Hsu I., and Pouliot J. Cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer. J App Clin Med Phys 8 (2007) 1-13
-
(2007)
J App Clin Med Phys
, vol.8
, pp. 1-13
-
-
Kim, Y.1
Hsu, I.2
Pouliot, J.3
-
11
-
-
34147144508
-
A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer
-
Kim Y., Verhey L.J., and Xia P. A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer. Phys Med Biol 52 (2007) 2147-2156
-
(2007)
Phys Med Biol
, vol.52
, pp. 2147-2156
-
-
Kim, Y.1
Verhey, L.J.2
Xia, P.3
-
12
-
-
14744282491
-
GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer
-
Kovacs G., Potter R., Loch T., et al. GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer. Radiother Oncol 74 (2005) 137-148
-
(2005)
Radiother Oncol
, vol.74
, pp. 137-148
-
-
Kovacs, G.1
Potter, R.2
Loch, T.3
-
13
-
-
0036718529
-
Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate
-
Lachance B., Beliveau-Nadeau D., Lessard E., et al. Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate. Int J Radiat Oncol Biol Phys 54 (2002) 86-100
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.54
, pp. 86-100
-
-
Lachance, B.1
Beliveau-Nadeau, D.2
Lessard, E.3
-
14
-
-
0035010591
-
Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function
-
Lessard E., and Pouliot J. Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function. Med Phys 28 (2001) 773-779
-
(2001)
Med Phys
, vol.28
, pp. 773-779
-
-
Lessard, E.1
Pouliot, J.2
-
15
-
-
22444433291
-
Anatomy-based inverse planning dose optimization in HDR prostate implant: a toxicity study
-
Mahmoudieh A., Tremblay C., Beaulieu L., et al. Anatomy-based inverse planning dose optimization in HDR prostate implant: a toxicity study. Radiother Oncol 75 (2005) 318-324
-
(2005)
Radiother Oncol
, vol.75
, pp. 318-324
-
-
Mahmoudieh, A.1
Tremblay, C.2
Beaulieu, L.3
-
16
-
-
0032863710
-
New interstitial HDR brachytherapy technique for prostate cancer: CT based 3D planning after transrectal implantation
-
Martin T., Kolotas C., Dannenberg T., et al. New interstitial HDR brachytherapy technique for prostate cancer: CT based 3D planning after transrectal implantation. Radiother Oncol 52 (1999) 257-260
-
(1999)
Radiother Oncol
, vol.52
, pp. 257-260
-
-
Martin, T.1
Kolotas, C.2
Dannenberg, T.3
-
17
-
-
0037365611
-
Conformal high dose rate brachytherapy improves biochemical control and cause specific survival in patients with prostate cancer and poor prognostic factors
-
discussion 979-980
-
Martinez A.A., Gonzalez J., Spencer W., et al. Conformal high dose rate brachytherapy improves biochemical control and cause specific survival in patients with prostate cancer and poor prognostic factors. J Urol 169 (2003) 974-979 discussion 979-980
-
(2003)
J Urol
, vol.169
, pp. 974-979
-
-
Martinez, A.A.1
Gonzalez, J.2
Spencer, W.3
-
18
-
-
0036603734
-
Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer
-
Martinez A.A., Gustafson G., Gonzalez J., et al. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer. Int J Radiat Oncol Biol Phys 53 (2002) 316-327
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, pp. 316-327
-
-
Martinez, A.A.1
Gustafson, G.2
Gonzalez, J.3
-
19
-
-
3242673606
-
MRI-guided HDR prostate brachytherapy in standard 1.5 T scanner
-
Menard C., Susil R.C., Choyke P., et al. MRI-guided HDR prostate brachytherapy in standard 1.5 T scanner. Int J Radiat Oncol Biol Phys 59 (2004) 1414-1423
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 1414-1423
-
-
Menard, C.1
Susil, R.C.2
Choyke, P.3
-
20
-
-
2642569200
-
Development of a simultaneous boost IMRT class solution for a hypofractionated prostate cancer protocol
-
Mott J.H., Livsey J.E., and Logue J.P. Development of a simultaneous boost IMRT class solution for a hypofractionated prostate cancer protocol. Br J Radiol 77 (2004) 377-386
-
(2004)
Br J Radiol
, vol.77
, pp. 377-386
-
-
Mott, J.H.1
Livsey, J.E.2
Logue, J.P.3
-
21
-
-
36349013125
-
Optimal starting gantry angles using equiangular-spaced beams with intensity modulated radiation therapy for prostate cancer on RTOG 0126: a clinical study of 5 and 7 fields
-
Potrebko P.S., McCurdy B.M., Butler J.B., El-Gubtan A.S., and Nugent Z. Optimal starting gantry angles using equiangular-spaced beams with intensity modulated radiation therapy for prostate cancer on RTOG 0126: a clinical study of 5 and 7 fields. Radiother Oncol (2007)
-
(2007)
Radiother Oncol
-
-
Potrebko, P.S.1
McCurdy, B.M.2
Butler, J.B.3
El-Gubtan, A.S.4
Nugent, Z.5
-
22
-
-
3042658240
-
Inverse planning for HDR prostate brachytherapy used to boost dominant intraprostatic lesions defined by magnetic resonance spectroscopy imaging
-
Pouliot J., Kim Y., Lessard E., Hsu I.C., Vigneron D.B., and Kurhanewicz J. Inverse planning for HDR prostate brachytherapy used to boost dominant intraprostatic lesions defined by magnetic resonance spectroscopy imaging. Int J Radiat Oncol Biol Phys 59 (2004) 1196-1207
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 1196-1207
-
-
Pouliot, J.1
Kim, Y.2
Lessard, E.3
Hsu, I.C.4
Vigneron, D.B.5
Kurhanewicz, J.6
-
23
-
-
45849083819
-
Advanced 3-D planning
-
Thomadsen B., Rivard M., and Butler W. (Eds), Medical Physics Publishing, Madison
-
Pouliot J., Lessard E., and Hsu I.C. Advanced 3-D planning. In: Thomadsen B., Rivard M., and Butler W. (Eds). Brachytherapy physics. Second ed. (2005), Medical Physics Publishing, Madison 393-414
-
(2005)
Brachytherapy physics. Second ed.
, pp. 393-414
-
-
Pouliot, J.1
Lessard, E.2
Hsu, I.C.3
-
24
-
-
33748856001
-
A comparison of prostate IMRT and helical tomotherapy class solutions
-
Rodrigues G., Yartsev S., Chen J., et al. A comparison of prostate IMRT and helical tomotherapy class solutions. Radiother Oncol 80 (2006) 374-377
-
(2006)
Radiother Oncol
, vol.80
, pp. 374-377
-
-
Rodrigues, G.1
Yartsev, S.2
Chen, J.3
-
25
-
-
34248380823
-
Early observed transient prostate-specific antigen elevations on a pilot study of external beam radiation therapy and fractionated MRI guided high dose rate brachytherapy boost
-
Singh A.K., Guion P., Susil R.C., et al. Early observed transient prostate-specific antigen elevations on a pilot study of external beam radiation therapy and fractionated MRI guided high dose rate brachytherapy boost. Radiat Oncol 1 (2006) 28
-
(2006)
Radiat Oncol
, vol.1
, pp. 28
-
-
Singh, A.K.1
Guion, P.2
Susil, R.C.3
-
26
-
-
0034001845
-
Use of conformal high-dose rate brachytherapy for management of patients with prostate cancer: optimizing dose escalation
-
Vicini F.A., Kestin L.L., and Martinez A.A. Use of conformal high-dose rate brachytherapy for management of patients with prostate cancer: optimizing dose escalation. Tech Urol 6 (2000) 135-145
-
(2000)
Tech Urol
, vol.6
, pp. 135-145
-
-
Vicini, F.A.1
Kestin, L.L.2
Martinez, A.A.3
-
27
-
-
2942553914
-
A study of planning dose constraints for treatment of nasopharyngeal carcinoma using a commercial inverse treatment planning system
-
Xia P., Lee N., Liu Y.M., et al. A study of planning dose constraints for treatment of nasopharyngeal carcinoma using a commercial inverse treatment planning system. Int J Radiat Oncol Biol Phys 59 (2004) 886-896
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 886-896
-
-
Xia, P.1
Lee, N.2
Liu, Y.M.3
-
28
-
-
22444432640
-
Evaluation of anatomy-based dwell position and inverse optimization in high-dose-rate brachytherapy of prostate cancer: a dosimetric comparison to a conventional cylindrical dwell position, geometric optimization, and dose-point optimization
-
Yoshioka Y., Nishimura T., Kamata M., et al. Evaluation of anatomy-based dwell position and inverse optimization in high-dose-rate brachytherapy of prostate cancer: a dosimetric comparison to a conventional cylindrical dwell position, geometric optimization, and dose-point optimization. Radiother Oncol 75 (2005) 311-317
-
(2005)
Radiother Oncol
, vol.75
, pp. 311-317
-
-
Yoshioka, Y.1
Nishimura, T.2
Kamata, M.3
|