Volumn 5, Issue 3, 2008, Pages 187-192

Analyzing misdiagnosis of 64-detector computed tomography coronary angiography

Author keywords

64 detect computed tomography coronary angiography; Conventional coronary angiography; Coronary artery disease; Misdiagnose

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ARTICLE; CHI SQUARE TEST; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; FALSE NEGATIVE RESULT; FALSE POSITIVE RESULT; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE;

EID: 45849123512     PISSN: 16728475     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (18)
  • 1
    • 33750879978 scopus 로고    scopus 로고
    • Coronary arteries angiography by 64-slice computed tomography
    • Wang XM, Wu LB, Li ZJ, et al. Coronary arteries angiography by 64-slice computed tomography. The Chinese Journal of Radiology, 2005,39(11):1201-1204.
    • (2005) The Chinese Journal of Radiology , vol.39 , Issue.11 , pp. 1201-1204
    • Wang, X.M.1    Wu, L.B.2    Li, Z.J.3
  • 2
    • 45849149412 scopus 로고    scopus 로고
    • The technology of coronary arteries angiography by 64-slice computed tomography
    • Zhang M, Li SL, Gun ZP, et al. The technology of coronary arteries angiography by 64-slice computed tomography. Chinese Journal of Medical Imaging Technology,2005,21(12):1948-1950.
    • (2005) Chinese Journal of Medical Imaging Technology , vol.21 , Issue.12 , pp. 1948-1950
    • Zhang, M.1    Li, S.L.2    Gun, Z.P.3
  • 3
    • 33646102670 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - comparison with conventional invasive angiography
    • Mariko MD, Jean-Francois MD, Masato RT, et al. Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - comparison with conventional invasive angiography. Circulation Journal,2006,70:(5)564-571
    • (2006) Circulation Journal , vol.70 , Issue.5 , pp. 564-571
    • Mariko, M.D.1    Jean-Francois, M.D.2    Masato, R.T.3
  • 4
    • 0242670021 scopus 로고    scopus 로고
    • Image quality in a standardized algorithm for minimally invasive coronary angiograhy with multislice spiral computed tomograhy
    • Gerber TC, Kuzo RS, Lane GE, et al. Image quality in a standardized algorithm for minimally invasive coronary angiograhy with multislice spiral computed tomograhy. Journal of Computer Assisted tomography, 2003, 27 (1): 62.
    • (2003) Journal of Computer Assisted tomography , vol.27 , Issue.1 , pp. 62
    • Gerber, T.C.1    Kuzo, R.S.2    Lane, G.E.3
  • 5
    • 33749624597 scopus 로고    scopus 로고
    • The value of diagnosis of coronary artery disease by 64-detector computed tomography
    • Meng L, Zhang ZQ, Lv B, et al. The value of diagnosis of coronary artery disease by 64-detector computed tomography. The Chinese Journal of Radiology,2006,40(8):792-796.
    • (2006) The Chinese Journal of Radiology , vol.40 , Issue.8 , pp. 792-796
    • Meng, L.1    Zhang, Z.Q.2    Lv, B.3
  • 6
    • 45849103289 scopus 로고    scopus 로고
    • Heart rate and phase of reconstruction builds the influence to the image quantity of the multislice computed tomography for detecting coronary arteries angiography
    • Mao DB, Hua YQ, Wang MP, et al. Heart rate and phase of reconstruction builds the influence to the image quantity of the multislice computed tomography for detecting coronary arteries angiography. Chinese Journal of Radiology, 2005, 38(5):521-524.
    • (2005) Chinese Journal of Radiology , vol.38 , Issue.5 , pp. 521-524
    • Mao, D.B.1    Hua, Y.Q.2    Wang, M.P.3
  • 7
    • 33749640327 scopus 로고    scopus 로고
    • Primary research of 64-silice computed tomography coronary angiography
    • Wang YN, Jin ZY, Kong LY, et al. Primary research of 64-silice computed tomography coronary angiography. Chinese Journal of Radiology,2006,40(8):797-801.
    • (2006) Chinese Journal of Radiology , vol.40 , Issue.8 , pp. 797-801
    • Wang, Y.N.1    Jin, Z.Y.2    Kong, L.Y.3
  • 8
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease: Report of the AdHoc committee for Grading of Coronary Artery disease, Council on Cardiovascular surgery, American Heart Association
    • Austen W, Edward J, Frye R, et al. A reporting system on patients evaluated for coronary artery disease: report of the AdHoc committee for Grading of Coronary Artery disease, Council on Cardiovascular surgery, American Heart Association. Circulation, 1975,51(1):5-50.
    • (1975) Circulation , vol.51 , Issue.1 , pp. 5-50
    • Austen, W.1    Edward, J.2    Frye, R.3
  • 9
    • 45849132861 scopus 로고    scopus 로고
    • Techniques and protocols for acquisition and display of contrast-enhanced CT angiography
    • New Jersy: Humana Press
    • Becker CR. Techniques and protocols for acquisition and display of contrast-enhanced CT angiography. CT of heart, principles and applications. New Jersy: Humana Press,2007:229-235.
    • (2007) CT of heart, principles and applications , pp. 229-235
    • Becker, C.R.1
  • 10
    • 45849102199 scopus 로고
    • Safety and cost effectiveness of high-osmolality contrast material in patients undergoing cardiac angiography
    • Steinberg EP, Moore RD, Powe NR, et al. Safety and cost effectiveness of high-osmolality contrast material in patients undergoing cardiac angiography. N Engl J Med,1992:80(6):727-732.
    • (1992) N Engl J Med , vol.80 , Issue.6 , pp. 727-732
    • Steinberg, E.P.1    Moore, R.D.2    Powe, N.R.3
  • 11
    • 2542596891 scopus 로고    scopus 로고
    • Pitfalls, artifacts, and remedies in multidetector row CT coronary angiography
    • Choi HS, Choi BW, Choe KO, et al. Pitfalls, artifacts, and remedies in multidetector row CT coronary angiography. Radiographics, 2004,24(6):787-800.
    • (2004) Radiographics , vol.24 , Issue.6 , pp. 787-800
    • Choi, H.S.1    Choi, B.W.2    Choe, K.O.3
  • 12
    • 45849117384 scopus 로고    scopus 로고
    • The factor to influence image qulity and scanning technique of silice computed tomography coronary angiography
    • Lei ZQ, Han P, Kong XQ, et al. The factor to influence image qulity and scanning technique of silice computed tomography coronary angiography. Journal of Clinical Radiology, 2005, 24(1): 77-80.
    • (2005) Journal of Clinical Radiology , vol.24 , Issue.1 , pp. 77-80
    • Lei, Z.Q.1    Han, P.2    Kong, X.Q.3
  • 13
    • 0347357884 scopus 로고    scopus 로고
    • Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multi-detector spiral computed tomography:a segment-based comparison with intravascular ultrasound
    • Achenbach S, Moselewski F, Repers D, et al. Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multi-detector spiral computed tomography:a segment-based comparison with intravascular ultrasound. circulation, 2004,109(1):14-17.
    • (2004) circulation , vol.109 , Issue.1 , pp. 14-17
    • Achenbach, S.1    Moselewski, F.2    Repers, D.3
  • 14
    • 11244343935 scopus 로고    scopus 로고
    • Multislice CT imaging of anomalous coronary arteries
    • Shi H, Aschoff AJ, Brambs HJ, et al. Multislice CT imaging of anomalous coronary arteries. Eur radiol, 2004, 14(4):2172-2181.
    • (2004) Eur radiol , vol.14 , Issue.4 , pp. 2172-2181
    • Shi, H.1    Aschoff, A.J.2    Brambs, H.J.3
  • 15
    • 34250664852 scopus 로고    scopus 로고
    • The multislice computed tomography coronary angiography: The influence to the image quantity of phase reconstruction and heart rate
    • Chen Y, Han P, Liang B, et al. The multislice computed tomography coronary angiography: The influence to the image quantity of phase reconstruction and heart rate. Chinese Journal of Medical Imaging Technology, 2005,21(3):425-429.
    • (2005) Chinese Journal of Medical Imaging Technology , vol.21 , Issue.3 , pp. 425-429
    • Chen, Y.1    Han, P.2    Liang, B.3
  • 16
    • 10744229899 scopus 로고    scopus 로고
    • Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease
    • Kuettner A, Kopp AF, Schroeder S, et al. Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. J Am Coll Cardiol, 2004,43(6):831-839.
    • (2004) J Am Coll Cardiol , vol.43 , Issue.6 , pp. 831-839
    • Kuettner, A.1    Kopp, A.F.2    Schroeder, S.3
  • 17
    • 0034311878 scopus 로고    scopus 로고
    • Current development of cardiac imaging with multidector-row CT
    • Becker CR, Ohnesorge BM, Schoepf UJ, et al. Current development of cardiac imaging with multidector-row CT. Eur Jr-adiol, 2000,36(2):97-103.
    • (2000) Eur Jr-adiol , vol.36 , Issue.2 , pp. 97-103
    • Becker, C.R.1    Ohnesorge, B.M.2    Schoepf, U.J.3
  • 18
    • 21844447153 scopus 로고    scopus 로고
    • Usefulness of noninvasive msCT coronary angiography as first-line imaging technique in patients with chest pain: Initial clinical experience B
    • Schroederas, Kuettnerb A, Becka T, et al. Usefulness of noninvasive msCT coronary angiography as first-line imaging technique in patients with chest pain: initial clinical experience B. International Journal of Cardiology, 2005, 102 (3): 425-429
    • (2005) International Journal of Cardiology , vol.102 , Issue.3 , pp. 425-429
    • Schroederas1    Kuettnerb, A.2    Becka, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.