메뉴 건너뛰기




Volumn 26, Issue 6, 2008, Pages 721-726

Feasibility of using hyperpolarized [1-13C]lactate as a substrate for in vivo metabolic 13C MRSI studies

Author keywords

C13; DNP; MRSI

Indexed keywords

ALANINE; BICARBONATE; CARBON 13; LACTIC ACID; PYRUVIC ACID;

EID: 45849120216     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2008.01.002     Document Type: Article
Times cited : (100)

References (9)
  • 4
    • 36849029752 scopus 로고    scopus 로고
    • Chen AP, Alberts MJ, Cunningham CH, Kohler SJ, Yen Y, Hurd RE, et al. Hyperpolarized C-13 spectroscopic imaging of the TRAMP mouse at 3T - initial experience. Magn Reson Med 2007;58(6):1294-8.
    • Chen AP, Alberts MJ, Cunningham CH, Kohler SJ, Yen Y, Hurd RE, et al. Hyperpolarized C-13 spectroscopic imaging of the TRAMP mouse at 3T - initial experience. Magn Reson Med 2007;58(6):1294-8.
  • 5
    • 34547746449 scopus 로고    scopus 로고
    • In vivo 13 carbon metabolic imaging at 3T with hyperpolarized 13C-1-pyruvate
    • Kohler S.J., Yen Y., Wolber J., Chen A.P., Albers M.J., Bok R., et al. In vivo 13 carbon metabolic imaging at 3T with hyperpolarized 13C-1-pyruvate. Magn Res Med 58 1 (2007) 65-69
    • (2007) Magn Res Med , vol.58 , Issue.1 , pp. 65-69
    • Kohler, S.J.1    Yen, Y.2    Wolber, J.3    Chen, A.P.4    Albers, M.J.5    Bok, R.6
  • 6
    • 45849130666 scopus 로고    scopus 로고
    • Kinetic modeling of hyperpolarized 13C1-pyruvate metabolism using dynamic magnetic resonance spectroscopy. International Society for Magnetic Resonance
    • Berlin, Germany
    • Zierhut M.L., Chen A.P., Bok R., Albers M., Zhang V., Pels P., et al. Kinetic modeling of hyperpolarized 13C1-pyruvate metabolism using dynamic magnetic resonance spectroscopy. International Society for Magnetic Resonance. Medicine 15th annual meeting (2007) 366 Berlin, Germany
    • (2007) Medicine 15th annual meeting , pp. 366
    • Zierhut, M.L.1    Chen, A.P.2    Bok, R.3    Albers, M.4    Zhang, V.5    Pels, P.6
  • 7
    • 38249019089 scopus 로고
    • Design and evaluation of a novel dual-tuned resonator for spectroscopic imaging
    • Derby K., Tropp J., and Hawryszko C. Design and evaluation of a novel dual-tuned resonator for spectroscopic imaging. J Magn Reson 86 (1990) 645-651
    • (1990) J Magn Reson , vol.86 , pp. 645-651
    • Derby, K.1    Tropp, J.2    Hawryszko, C.3
  • 8
    • 0032587954 scopus 로고    scopus 로고
    • Fast T1 mapping on a whole-body scanner
    • Deichmann R., Hahn D., and Haase A. Fast T1 mapping on a whole-body scanner. Magn Res Med 42 (1999) 206-209
    • (1999) Magn Res Med , vol.42 , pp. 206-209
    • Deichmann, R.1    Hahn, D.2    Haase, A.3
  • 9
    • 27644551824 scopus 로고    scopus 로고
    • Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging
    • Cunningham C., Vigneron D., Chen A., Xu D., Nelson S., Hurd R., et al. Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging. Magn Res Med 54 (2005) 1286-1289
    • (2005) Magn Res Med , vol.54 , pp. 1286-1289
    • Cunningham, C.1    Vigneron, D.2    Chen, A.3    Xu, D.4    Nelson, S.5    Hurd, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.