메뉴 건너뛰기




Volumn 7, Issue , 2008, Pages

A new adhesive technique for internal fixation in midfacial surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADHESION FORCES; ADHESIVE BONDING; AMPHIPHILIC(AP); APPLIED (CO); BONDING STRENGTHS; BONE BONDING; BONE FRAGMENTS; BONE HEALING; BONE SURFACES; CORTICAL BONES; CORTICAL BOVINE; DENTIN BONDING AGENTS; FIXATION SYSTEMS; IN ORDER; IN-VITRO; LOAD BEARING; METAL PLATES; ORTHOTOPIC; OSTEOSYNTHESIS; PILOT HOLE (PH); POLYMETHYLMETHACRYLATE (PMMA) BONE CEMENT; PRIMARY STABILITY; RELATIVELY CONSTANT; SURGICAL THERAPIES; TENSION TESTS; WET STORAGE;

EID: 45849115063     PISSN: 1475925X     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-7-16     Document Type: Article
Times cited : (23)

References (38)
  • 2
    • 0025987986 scopus 로고
    • Plattenosteosynthese in der Traumatologie des Mittelgesichtes- Ein Fortschritt?
    • 1869202
    • Luhr HG Plattenosteosynthese in der Traumatologie des Mittelgesichtes- ein Fortschritt? Fortschr Kiefer- Gesichtschir 1991, 36:30-33. 1869202
    • (1991) Fortschr Kiefer- Gesichtschir , vol.36 , pp. 30-33
    • Luhr, H.G.1
  • 3
    • 2942637375 scopus 로고    scopus 로고
    • Comparison of the bond strength of selected adhesive dental systems to cortical bone under in vitro conditions
    • 10.1016/j.ijom.2003.10.020 15145041
    • Maurer P Bekes K Gernhardt CR Schaller H-G Schubert J Comparison of the bond strength of selected adhesive dental systems to cortical bone under in vitro conditions Int J Oral Maxillofac Surg 2004, 33:377-381. 10.1016/ j.ijom.2003.10.020 15145041
    • (2004) Int J Oral Maxillofac Surg , vol.33 , pp. 377-381
    • Maurer, P.1    Bekes, K.2    Gernhardt, C.R.3    Schaller, H.-G.4    Schubert, J.5
  • 4
    • 24144459619 scopus 로고    scopus 로고
    • Current Therapy: Complications Associated with Rigid Internal Fixation of Facial Fractures
    • Aziz SR Ziccardi VB Borah G Current Therapy: Complications Associated with Rigid Internal Fixation of Facial Fractures Compend Contin Educ Dent 2005, 8:565-571.
    • (2005) Compend Contin Educ Dent , vol.8 , pp. 565-571
    • Aziz, S.R.1    Ziccardi, V.B.2    Borah, G.3
  • 5
    • 0025901178 scopus 로고
    • Application of microfixation techniques in reconstructive maxillofacial surgery
    • 2056364
    • Eppley BL Sadove AM Application of microfixation techniques in reconstructive maxillofacial surgery J Oral Maxillofac Surg 1991, 49:683-688. 2056364
    • (1991) J Oral Maxillofac Surg , vol.49 , pp. 683-688
    • Eppley, B.L.1    Sadove, A.M.2
  • 6
    • 0025220169 scopus 로고
    • Indications for Use of a Microsystem for Internal Fixation in Craniofacial Surgery
    • 10.1097/00001665-199001000-00009 2088562
    • Luhr HG Indications for Use of a Microsystem for Internal Fixation in Craniofacial Surgery J Craniofac Surg 1990, 1:35-52. 10.1097/ 00001665-199001000-00009 2088562
    • (1990) J Craniofac Surg , vol.1 , pp. 35-52
    • Luhr, H.G.1
  • 7
    • 0032992572 scopus 로고    scopus 로고
    • Complications of Internal Fixation of Maxillofacial Fractures with Microplates
    • 9973119
    • Schortingbuis J Bos RRM Vissink A Complications of Internal Fixation of Maxillofacial Fractures with Microplates J Oral Maxillofac Surg 1999, 57:130-134. 10.1016/S0278-2391(99)90224-0 9973119
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 130-134
    • Schortingbuis, J.1    Bos, R.R.M.2    Vissink, A.3
  • 8
    • 0026795590 scopus 로고
    • The loadability of the 0.8 mm microsystem in thin midfacial regions: An animal experimental study
    • 1401105
    • Bähr W Lessing R The loadability of the 0.8 mm microsystem in thin midfacial regions: An animal experimental study J Craniomaxillofac Surg 1992, 20:287-291. 1401105
    • (1992) J Craniomaxillofac Surg , vol.20 , pp. 287-291
    • Bähr, W.1    Lessing, R.2
  • 9
    • 0003943122 scopus 로고    scopus 로고
    • Berlin Heidelberg New York: Springer Verlag
    • Adler CP Knochenkrankheiten Berlin Heidelberg New York: Springer Verlag 2004
    • (2004) Knochenkrankheiten
    • Adler, C.P.1
  • 10
    • 45849097726 scopus 로고    scopus 로고
    • Drill-Free-Schrauben: In-vitro-Tests, In-vivo-Untersuchungen und klinische Anwendungen selbstbohrender und selbstschneidender Osteosyntheseschrauben in der Mund- Kiefer- Gesichtschirurgie
    • Zahnmed Dissertation. Martin-Luther-Universität Halle-Wittenberg, Medizinischen Fakultät
    • Heidemann W Drill-Free-Schrauben: In-vitro-Tests, In-vivo-Untersuchungen und klinische Anwendungen selbstbohrender und selbstschneidender Osteosyntheseschrauben in der Mund- Kiefer- Gesichtschirurgie Zahnmed Dissertation. Martin-Luther-Universität Halle-Wittenberg, Medizinischen Fakultät 2001
    • (2001)
    • Heidemann, W.1
  • 14
    • 0029051011 scopus 로고
    • In vitro fracture fixation: Adhesive systems compared with a conventionel technique
    • 10.1016/0266-4356(95)90004-7 8736747
    • Perry MJ Youngson CC In vitro fracture fixation: Adhesive systems compared with a conventionel technique Br J Oral Maxillofac Surg 1995, 33:224-227. 10.1016/0266-4356(95)90004-7 8736747
    • (1995) Br J Oral Maxillofac Surg , vol.33 , pp. 224-227
    • Perry, M.J.1    Youngson, C.C.2
  • 15
    • 0031844184 scopus 로고    scopus 로고
    • Fixation of the craniofacial skeleton with butyl-2-cyanoacrylate and its effects on histotoxicity and healing
    • 10.1097/00006534-199808000-00003 9703064
    • Shermack M Wong L Inoue N Crain BJ Im MJ Chao EYS Manson PN Fixation of the craniofacial skeleton with butyl-2-cyanoacrylate and its effects on histotoxicity and healing Plast Reconstr Surg 1998, 102:309-318. 10.1097/ 00006534-199808000-00003 9703064
    • (1998) Plast Reconstr Surg , vol.102 , pp. 309-318
    • Shermack, M.1    Wong, L.2    Inoue, N.3    Crain, B.J.4    Im, M.J.5    Chao, E.Y.S.6    Manson, P.N.7
  • 16
    • 33847777166 scopus 로고    scopus 로고
    • Partially adhesive fixation of reconstruction plates at midfacial fractures - An alternative solution to screw fixation?
    • 10.1002/mawe.200600100
    • Smeets R Riediger D Wirtz DC Marx R Endres K Partially adhesive fixation of reconstruction plates at midfacial fractures - an alternative solution to screw fixation? Mat Werkstofftech 2007, 38:178-180. 10.1002/ mawe.200600100
    • (2007) Mat Werkstofftech , vol.38 , pp. 178-180
    • Smeets, R.1    Riediger, D.2    Wirtz, D.C.3    Marx, R.4    Endres, K.5
  • 17
    • 5044235580 scopus 로고    scopus 로고
    • The tissue response to an alkylene bis(dilactoyl)-methacrylate bone adhesive
    • 10.1016/j.biomaterials.2004.04.048 15482826
    • Heiss C Hahn N Wenisch S Alt V Pokinskyj P Horas U Kilian O Schnettler R The tissue response to an alkylene bis(dilactoyl)-methacrylate bone adhesive Biomaterials. 2005, 26(12):1389-1396. 10.1016/ j.biomaterials.2004.04.048 15482826
    • (2005) Biomaterials. , vol.26 , Issue.12 , pp. 1389-1396
    • Heiss, C.1    Hahn, N.2    Wenisch, S.3    Alt, V.4    Pokinskyj, P.5    Horas, U.6    Kilian, O.7    Schnettler, R.8
  • 18
    • 0032142902 scopus 로고    scopus 로고
    • Tissues and bone adhesives - Historical aspects
    • 10.1016/S0142-9612(98)00059-3 9794519
    • Donckerwolke M Burny F Muster D Tissues and bone adhesives - historical aspects Biomaterials 1998, 19(16):1461-1466. 10.1016/ S0142-9612(98)00059-3 9794519
    • (1998) Biomaterials , vol.19 , Issue.16 , pp. 1461-1466
    • Donckerwolke, M.1    Burny, F.2    Muster, D.3
  • 19
    • 33645009638 scopus 로고    scopus 로고
    • Deleterious tissue reaction to an alkylene bis(dilactoyl)-methacrylate bone adhesive in long-term follow up after screw augmentation in an bovine model
    • 10.1016/j.biomaterials.2006.01.051
    • Grossterlinden L Janssen A Schmitz N Priemel M Pogoda P Amling M Rueger JM Linhart W Deleterious tissue reaction to an alkylene bis(dilactoyl)-methacrylate bone adhesive in long-term follow up after screw augmentation in an bovine model Biomat 2006, 27:3379-3386. 10.1016/ j.biomaterials.2006.01.051
    • (2006) Biomat , vol.27 , pp. 3379-3386
    • Grossterlinden, L.1    Janssen, A.2    Schmitz, N.3    Priemel, M.4    Pogoda, P.5    Amling, M.6    Rueger, J.M.7    Linhart, W.8
  • 20
    • 0036013942 scopus 로고    scopus 로고
    • Fibrin glue as an osteoinductive protein in a mouse model
    • 10.1016/S0142-9612(02)00064-9 12069345
    • Abiraman S Varma HK Umashankar PR John A Fibrin glue as an osteoinductive protein in a mouse model Biomaterials 2002, 23(14):3023-3031. 10.1016/S0142-9612(02)00064-9 12069345
    • (2002) Biomaterials , vol.23 , Issue.14 , pp. 3023-3031
    • Abiraman, S.1    Varma, H.K.2    Umashankar, P.R.3    John, A.4
  • 21
    • 0013934176 scopus 로고
    • The healing of human fractures in contact with self-curing acrylic cement
    • 5923183
    • Charnley J The healing of human fractures in contact with self-curing acrylic cement Clin Orthop 1966, 47:157-163. 5923183
    • (1966) Clin Orthop , vol.47 , pp. 157-163
    • Charnley, J.1
  • 23
    • 3042515208 scopus 로고    scopus 로고
    • Surface pretreatments for medical application of adhesion
    • 222922 14561228 10.1186/1475-925X-2-15
    • Erli HJ Marx R Paar O Niethard FU Weber M Wirtz DC Surface pretreatments for medical application of adhesion BioMed Eng OnLine 2003, 2:15-32. 222922 14561228 10.1186/1475-925X-2-15
    • (2003) BioMed Eng OnLine , vol.2 , pp. 15-32
    • Erli, H.J.1    Marx, R.2    Paar, O.3    Niethard, F.U.4    Weber, M.5    Wirtz, D.C.6
  • 25
    • 0038028670 scopus 로고    scopus 로고
    • Eine neue Methode zur Optimierung der Verbundfestigkeit zwischen Knochenzement und azetabulärem Knochen beim künstlichen Hüftgelenkersatz
    • 10.1055/s-2003-38661
    • Wirtz DC Lelgemann B Jungwirth F Niethard FU Marx R Eine neue Methode zur Optimierung der Verbundfestigkeit zwischen Knochenzement und azetabulärem Knochen beim künstlichen Hüftgelenkersatz Z Orthop Unfallch 2003, 141:209-216. 10.1055/s-2003-38661
    • (2003) Z Orthop Unfallch , vol.141 , pp. 209-216
    • Wirtz, D.C.1    Lelgemann, B.2    Jungwirth, F.3    Niethard, F.U.4    Marx, R.5
  • 26
    • 0003979031 scopus 로고
    • Edinburgh and London: E&S Livingstone, Longman Group Limited Press
    • Charnley J Acrylic Cement in Orthopaedic Surgery Edinburgh and London: E&S Livingstone, Longman Group Limited Press 1970
    • (1970) Acrylic Cement in Orthopaedic Surgery
    • Charnley, J.1
  • 27
    • 45849115233 scopus 로고    scopus 로고
    • Bone coupling agent, layered adhesive system and method for making said coupling agent
    • EP 1429814
    • Marx R Fischer H Niethard FU Wirtz DC Bone coupling agent, layered adhesive system and method for making said coupling agent 2005 EP 1429814
    • (2005)
    • Marx, R.1    Fischer, H.2    Niethard, F.U.3    Wirtz, D.C.4
  • 28
    • 0015592550 scopus 로고
    • Lutes, glues, cements and adhesives in medcine and dentistry
    • 4571750
    • Smith DC Lutes, glues, cements and adhesives in medcine and dentistry Biomed Eng 1973, 8:;108-115. 4571750
    • (1973) Biomed Eng , vol.8 , pp. 108-115
    • Smith, D.C.1
  • 29
    • 1542619774 scopus 로고    scopus 로고
    • Tensile bond strength of different adhesive systems between bone and composite compared: An in vitro study
    • 14980587
    • Maurer P Bekes K Gernhardt CR Schaller H-G Schubert J Tensile bond strength of different adhesive systems between bone and composite compared: An in vitro study J Craniomaxillofac Surg 2004, 32:85-89. 14980587
    • (2004) J Craniomaxillofac Surg , vol.32 , pp. 85-89
    • Maurer, P.1    Bekes, K.2    Gernhardt, C.R.3    Schaller, H.-G.4    Schubert, J.5
  • 31
    • 34547691956 scopus 로고    scopus 로고
    • Die Haftkraft verschiedener Dentinhaftvermittler auf kortikalem Schweineknochen in vitro
    • Martin-Luther-Universität Halle-Wittenberg, Universitätsklinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie
    • Bekes K Die Haftkraft verschiedener Dentinhaftvermittler auf kortikalem Schweineknochen in vitro Zahnmed Dissertation Martin-Luther-Universität Halle-Wittenberg, Universitätsklinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie 2003
    • (2003) Zahnmed Dissertation
    • Bekes, K.1
  • 32
    • 45849132178 scopus 로고    scopus 로고
    • Klinik für Zahnärztliche Prothetik Lehr- und Forschungsgebiet Zahnärztliche Werkstoffkunde
    • Marx R Forschungsbericht 2005 Klinik für Zahnärztliche Prothetik Lehr- und Forschungsgebiet Zahnärztliche Werkstoffkunde
    • Forschungsbericht 2005
    • Marx, R.1
  • 33
    • 45849150921 scopus 로고    scopus 로고
    • Eine neue Methode zur Optimierung der Verbundfestigkeit zwischen Knochenzement und acetabulärem Knochen beim künstlichen Hüftgelenkersatz: In-vitro Testserie an Schafshüften
    • Mumme T Müller-Rath R Jungwirth F Marx R Wirtz D-C Eine neue Methode zur Optimierung der Verbundfestigkeit zwischen Knochenzement und acetabulärem Knochen beim künstlichen Hüftgelenkersatz: in-vitro Testserie an Schafshüften Meeting Abstract DGOOC 2004
    • (2004) Meeting Abstract DGOOC
    • Mumme, T.1    Müller-Rath, R.2    Jungwirth, F.3    Marx, R.4    Wirtz, D.-C.5
  • 34
    • 35348821793 scopus 로고    scopus 로고
    • Einsatz eines amphiphilen Haftvermittlers im Schafsmodell zur Verbesserung der femoralen Knochenzement-Knochen-Verbundfestigkeit in der zementierten Hüftendoprothetik
    • 10.1055/s-2007-965486 17912668
    • Müller-Rath R Wirtz D-C Andereya S Gravius S Hermanns-Sachweh B Marx R Mumme T Einsatz eines amphiphilen Haftvermittlers im Schafsmodell zur Verbesserung der femoralen Knochenzement-Knochen-Verbundfestigkeit in der zementierten Hüftendoprothetik Z Orthop Unfall 2007, 145:476-482. 10.1055/s-2007-965486 17912668
    • (2007) Z Orthop Unfall , vol.145 , pp. 476-482
    • Müller-Rath, R.1    Wirtz, D.-C.2    Andereya, S.3    Gravius, S.4    Hermanns-Sachweh, B.5    Marx, R.6    Mumme, T.7
  • 35
    • 0000781654 scopus 로고
    • A study of some factors which affect the strength of screws and their insertion and holding power in bone
    • 10.1016/0021-9290(68)90023-7 16329432
    • Ansell RH Scales JT A study of some factors which affect the strength of screws and their insertion and holding power in bone J Biomech 1968, 1:279-302. 10.1016/0021-9290(68)90023-7 16329432
    • (1968) J Biomech , vol.1 , pp. 279-302
    • Ansell, R.H.1    Scales, J.T.2
  • 36
    • 0015378503 scopus 로고
    • The mechanical properties of surgical bone screws and some aspects of insertion practice
    • 10.1016/S0020-1383(72)80007-X 4665143
    • Hughes AN Jordan BA The mechanical properties of surgical bone screws and some aspects of insertion practice Injury 1972, 4:25-38. 10.1016/ S0020-1383(72)80007-X 4665143
    • (1972) Injury , vol.4 , pp. 25-38
    • Hughes, A.N.1    Jordan, B.A.2
  • 37
    • 0018853628 scopus 로고
    • Messungen zur Kraftübertragung mit Knochenschrauben
    • Schmid F Dir B Messungen zur Kraftübertragung mit Knochenschrauben Dtsch Zahnärztl Z 1980, 35:28-31.
    • (1980) Dtsch Zahnärztl Z , vol.35 , pp. 28-31
    • Schmid, F.1    Dir, B.2
  • 38
    • 0032062560 scopus 로고    scopus 로고
    • Auswirkung verschiedener Bohrlochdurchmesser auf die Haltekraft von Osteosyntheseschrauben
    • 10.1007/s100060050048 9658803
    • Heidemann W Gerlach KL Gröbel K-H Köllner H-G Auswirkung verschiedener Bohrlochdurchmesser auf die Haltekraft von Osteosyntheseschrauben Mund Kiefer GesichtsChir 1998, 2:136-140. 10.1007/ s100060050048 9658803
    • (1998) Mund Kiefer GesichtsChir , vol.2 , pp. 136-140
    • Heidemann, W.1    Gerlach, K.L.2    Gröbel, K.-H.3    Köllner, H.-G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.