메뉴 건너뛰기




Volumn 15, Issue 4, 2008, Pages 305-308

Which is the best fixation method for lateral cortex disruption in the medial open wedge high tibial osteotomy? A biomechanical study

Author keywords

Biomechanical; Lateral cortex disruption; Osteotomy

Indexed keywords

ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CONTROLLED STUDY; FRACTURE EXTERNAL FIXATION; FRACTURE FIXATION; HUMAN; HUMAN CELL; HUMAN TISSUE; INTRAOPERATIVE PERIOD; JOINT STABILITY; PRIORITY JOURNAL; STAPLER; SURGICAL TECHNIQUE; TIBIA OSTEOTOMY;

EID: 45849099436     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2008.04.004     Document Type: Article
Times cited : (33)

References (12)
  • 1
    • 33644869113 scopus 로고    scopus 로고
    • High tibial osteotomy for medial compartment osteoarthritis
    • Dowd G.S., Somayaji H.S., and Uthukuri M. High tibial osteotomy for medial compartment osteoarthritis. Knee 13 2 (2006) 87-92
    • (2006) Knee , vol.13 , Issue.2 , pp. 87-92
    • Dowd, G.S.1    Somayaji, H.S.2    Uthukuri, M.3
  • 2
    • 0027453062 scopus 로고
    • Proximal tibial osteotomy: a critical long term study of eighty-seven cases
    • Coventry M.B., Ilstrup D.M., and Wallrichs S.L. Proximal tibial osteotomy: a critical long term study of eighty-seven cases. J Bone Joint Surg [Am] 75 A (1993) 196-201
    • (1993) J Bone Joint Surg [Am] , vol.75 A , pp. 196-201
    • Coventry, M.B.1    Ilstrup, D.M.2    Wallrichs, S.L.3
  • 3
    • 9744273970 scopus 로고    scopus 로고
    • Fifteen to twenty-eight years' follow-up results of high tibial valgus osteotomy for osteoarthritic
    • Koshino T., Yoshida T., Ara Y., Saito I., and Saito T. Fifteen to twenty-eight years' follow-up results of high tibial valgus osteotomy for osteoarthritic. Knee 11 6 (2004) 439-444
    • (2004) Knee , vol.11 , Issue.6 , pp. 439-444
    • Koshino, T.1    Yoshida, T.2    Ara, Y.3    Saito, I.4    Saito, T.5
  • 4
    • 0023181959 scopus 로고
    • Proximal tibial osteotomy for osteoarthritis with varus deformity: a ten to thirteen-year follow up study
    • Hernigou P., Medevielle D., Debeyre J., and Goutallier D. Proximal tibial osteotomy for osteoarthritis with varus deformity: a ten to thirteen-year follow up study. J Bone Joint Surg [Am] 69A (1987) 332-354
    • (1987) J Bone Joint Surg [Am] , vol.69 A , pp. 332-354
    • Hernigou, P.1    Medevielle, D.2    Debeyre, J.3    Goutallier, D.4
  • 5
    • 12944308336 scopus 로고    scopus 로고
    • Delayed- and non-union following opening wedge high tibial osteotomy: surgeons' results from 182 completed cases
    • Warden S.J., Morris H.G., Crossley K.M., Brukner P.D., and Bennell K.L. Delayed- and non-union following opening wedge high tibial osteotomy: surgeons' results from 182 completed cases. Knee surg Sports Traumatol Arthrosc 13 1 (2004) 34-37
    • (2004) Knee surg Sports Traumatol Arthrosc , vol.13 , Issue.1 , pp. 34-37
    • Warden, S.J.1    Morris, H.G.2    Crossley, K.M.3    Brukner, P.D.4    Bennell, K.L.5
  • 6
    • 12944336549 scopus 로고    scopus 로고
    • Open-wedge high tibial osteotomy: a technical trick to avoid loss of reduction of the opposite cortex
    • Paccola C.A.J., and Fogagnolo F. Open-wedge high tibial osteotomy: a technical trick to avoid loss of reduction of the opposite cortex. Knee surg Sports Traumatol Arthrosc 13 (2005) 19-22
    • (2005) Knee surg Sports Traumatol Arthrosc , vol.13 , pp. 19-22
    • Paccola, C.A.J.1    Fogagnolo, F.2
  • 7
    • 0036911344 scopus 로고    scopus 로고
    • Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study
    • Spahn G., and Wittig R. Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci 7 (2002) 683-687
    • (2002) J Orthop Sci , vol.7 , pp. 683-687
    • Spahn, G.1    Wittig, R.2
  • 8
    • 4744356841 scopus 로고    scopus 로고
    • Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate
    • Stoffel K., Stachowiak G., and Kuster M. Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clin Biomech 19 (2004) 944-950
    • (2004) Clin Biomech , vol.19 , pp. 944-950
    • Stoffel, K.1    Stachowiak, G.2    Kuster, M.3
  • 9
    • 0032693161 scopus 로고    scopus 로고
    • Primary stability of different implants used in conjunction with high tibial osteotomy
    • Flamme C.H., Kohn D., and Kirsch L. Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119 7-8 (1999) 450-455
    • (1999) Arch Orthop Trauma Surg , vol.119 , Issue.7-8 , pp. 450-455
    • Flamme, C.H.1    Kohn, D.2    Kirsch, L.3
  • 11
    • 23244439438 scopus 로고    scopus 로고
    • Biomechanical stability of high tibial opening wedge osteotomy: Internal fixation versus external fixation
    • Zhim F., Laflamme G.Y., Viens H., Saidane K., and Yahia L. Biomechanical stability of high tibial opening wedge osteotomy: Internal fixation versus external fixation. Clin Biomech 20 (2005) 871-876
    • (2005) Clin Biomech , vol.20 , pp. 871-876
    • Zhim, F.1    Laflamme, G.Y.2    Viens, H.3    Saidane, K.4    Yahia, L.5
  • 12
    • 25844503814 scopus 로고    scopus 로고
    • The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy
    • Miller B.S., Dorsey O.P.W., Bryant C.R., and Austin J.C. The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy. J Sports Med [Am] 33 10 (2005) 1552-1557
    • (2005) J Sports Med [Am] , vol.33 , Issue.10 , pp. 1552-1557
    • Miller, B.S.1    Dorsey, O.P.W.2    Bryant, C.R.3    Austin, J.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.