메뉴 건너뛰기




Volumn 113 PART 2, Issue , 2007, Pages 200-210

Economic evaluation of benefits associated with automated fault detection and diagnosis in rooftop air conditioners

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONERS; AMERICAN SOCIETY; ANNUAL MEETINGS; APPLIED (CO); AUTOMATED FAULT DETECTION; CALIFORNIA; CONDITIONING UNITS; COST SAVINGS; CRITICAL SYSTEMS; ECONOMIC EVALUATION (EE); EQUIPMENT LIFE; FAULT DETECTION AND DIAGNOSIS (FDD) SYSTEMS; FAULT PREVENTION; HVAC APPLICATIONS; LOW COST SENSORS; MAINTENANCE INSPECTIONS; PAPER ADDRESSES; PAYBACK PERIOD (PBP); SERVICE ACTIVITIES; SERVICE COSTS; TECHNIQUE DEVELOPMENT; UTILITY COSTS;

EID: 45749149639     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (20)

References (17)
  • 1
    • 0032114824 scopus 로고    scopus 로고
    • Common faults and their impacts for rooftop air conditioners
    • Breuker, M.S., and J.E. Braun. 1998a. Common faults and their impacts for rooftop air conditioners. HVAC&R Research 4(3):303-18.
    • (1998) HVAC&R Research , vol.4 , Issue.3 , pp. 303-318
    • Breuker, M.S.1    Braun, J.E.2
  • 2
    • 0032183639 scopus 로고    scopus 로고
    • Evaluating the performance of a fault detection and diagnostic system for vapor compression equipment
    • Breuker, M.S., and J.E. Braun. 1998b. Evaluating the performance of a fault detection and diagnostic system for vapor compression equipment. HVAC&R Research 4(4):401-23.
    • (1998) HVAC&R Research , vol.4 , Issue.4 , pp. 401-423
    • Breuker, M.S.1    Braun, J.E.2
  • 3
    • 0034832405 scopus 로고    scopus 로고
    • Simple rule-based methods for fault detection and diagnostics applied to packaged air conditioners
    • Chen, B., and J.E. Braun. 2001. Simple rule-based methods for fault detection and diagnostics applied to packaged air conditioners. ASHRAE Transactions 107(1):847-57.
    • (2001) ASHRAE Transactions , vol.107 , Issue.1 , pp. 847-857
    • Chen, B.1    Braun, J.E.2
  • 4
    • 45749108111 scopus 로고    scopus 로고
    • Comstock, M.C, J.E. Braun, and B. Chen. 1999. Literature review for application of fault detection and diagnostic methods to vapor compression cooling equipment, Report # HL99-19. West Lafayette, IN: Purdue University, Ray W. Herrick Laboratories.
    • Comstock, M.C, J.E. Braun, and B. Chen. 1999. Literature review for application of fault detection and diagnostic methods to vapor compression cooling equipment, Report # HL99-19. West Lafayette, IN: Purdue University, Ray W. Herrick Laboratories.
  • 5
    • 0003801266 scopus 로고    scopus 로고
    • Demonstrating automated fault detection and diagnosis methods in real buildings
    • Espoo, Finland
    • Dexter, A., and J. Pakanen. 2001. Demonstrating automated fault detection and diagnosis methods in real buildings. Report for VTT Building Technology Symposium 217, Espoo, Finland.
    • (2001) Report for VTT Building Technology Symposium , vol.217
    • Dexter, A.1    Pakanen, J.2
  • 6
    • 14544268558 scopus 로고    scopus 로고
    • Methods for fault detection, diagnostics, and prognostics for building systems-A review, Part I
    • Katipamula, S., and M. Brambley. 2005a. Methods for fault detection, diagnostics, and prognostics for building systems-A review, Part I. HVAC&R Research 11(1):3-25.
    • (2005) HVAC&R Research , vol.11 , Issue.1 , pp. 3-25
    • Katipamula, S.1    Brambley, M.2
  • 7
    • 18944392642 scopus 로고    scopus 로고
    • Methods for fault detection, diagnostics, and prognostics for building systems-A review, Part II
    • Katipamula, S., and M. Brambley. 2005b. Methods for fault detection, diagnostics, and prognostics for building systems-A review, Part II. HVAC&R Research 11 (2): 169-88.
    • (2005) HVAC&R Research , vol.11 , Issue.2 , pp. 169-188
    • Katipamula, S.1    Brambley, M.2
  • 8
    • 0030311821 scopus 로고    scopus 로고
    • Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode
    • Levins, PW, C.K. Rice, and V.D. Baxter. 1996. Modeled and measured effects of compressor downsizing in an existing air conditioner/heat pump in the cooling mode. ASHRAE Transactions 102(2):22-33.
    • (1996) ASHRAE Transactions , vol.102 , Issue.2 , pp. 22-33
    • Levins, P.W.1    Rice, C.K.2    Baxter, V.D.3
  • 10
    • 45749099186 scopus 로고    scopus 로고
    • Li, H., and J.E. Braun. 2003. A survey of field service costs for rooftop air conditioners. Internal report, Ray W. Herrick Laboratories, Purdue University, West Lafayette, IN.
    • Li, H., and J.E. Braun. 2003. A survey of field service costs for rooftop air conditioners. Internal report, Ray W. Herrick Laboratories, Purdue University, West Lafayette, IN.
  • 11
    • 45749110470 scopus 로고    scopus 로고
    • Proceedings of the 2004 ACEEE Conference on Energy Efficiency in Buildings, Monterey, CA
    • CD
    • Li, H., and J.E. Braun. 2004. Application of automated fault detection and diagnostics for rooftop air conditioners in California. Proceedings of the 2004 ACEEE Conference on Energy Efficiency in Buildings, Monterey, CA [CD].
    • (2004)
    • Li, H.1    Braun, J.E.2
  • 12
    • 34247486917 scopus 로고    scopus 로고
    • A methodology for diagnosing multiple-simultaneous faults in vapor compression air conditioners
    • Li, H., and J.E. Braun. 2007a. A methodology for diagnosing multiple-simultaneous faults in vapor compression air conditioners. HVAS&R Research 13(2):369-95.
    • (2007) HVAS&R Research , vol.13 , Issue.2 , pp. 369-395
    • Li, H.1    Braun, J.E.2
  • 13
    • 33847224547 scopus 로고    scopus 로고
    • Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners
    • Li, H., and J.E. Braun. 2007b. Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners. International Journal of Refrigeration 30(3):546-64.
    • (2007) International Journal of Refrigeration , vol.30 , Issue.3 , pp. 546-564
    • Li, H.1    Braun, J.E.2
  • 14
    • 33846262435 scopus 로고    scopus 로고
    • An overall performance index for characterizing the economic impact of faults in direct expansion cooling equipment
    • Li, H., and J.E. Braun. 2007c. An overall performance index for characterizing the economic impact of faults in direct expansion cooling equipment. International Journal of Refrigeration 30(2):299-310.
    • (2007) International Journal of Refrigeration , vol.30 , Issue.2 , pp. 299-310
    • Li, H.1    Braun, J.E.2
  • 15
    • 0029754267 scopus 로고    scopus 로고
    • Minimizing operating costs of vapor compression equipment with optimal service scheduling
    • Rossi, T.M., and J.E. Braun. 1996. Minimizing operating costs of vapor compression equipment with optimal service scheduling. HVAC&R Research 2(1):23-47.
    • (1996) HVAC&R Research , vol.2 , Issue.1 , pp. 23-47
    • Rossi, T.M.1    Braun, J.E.2
  • 16
    • 0030736095 scopus 로고    scopus 로고
    • A statistical, rule-based fault detection and diagnostic method for vapor compression air conditioners
    • Rossi, T.M., and J.E. Braun. 1997. A statistical, rule-based fault detection and diagnostic method for vapor compression air conditioners. HVAC&R Research 3(1): 19-37.
    • (1997) HVAC&R Research , vol.3 , Issue.1 , pp. 19-37
    • Rossi, T.M.1    Braun, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.