Volumn 57, Issue 10, 2008, Pages 1651-1658

Benefits, limitations and uncertainty of in situ spectrometry

Author keywords

COD; Optical sensors; PCA; PLS; Spectrometry; Turbidimetry; Uncertainty

Indexed keywords

ABSORPTION; CORRELATION METHODS; SPECTROMETERS; SPECTROMETRY; TESTING;

EID: 45549107200     PISSN: 02731223     EISSN: None     Source Type: Book Series    
DOI: 10.2166/wst.2008.145     Document Type: Article
Times cited : (11)

References (5)
  • 1
    • 38649097844 scopus 로고    scopus 로고
    • Comparison of and uncertainties in raw sewage COD measurements by laboratory techniques and field UV-visible spectrometry
    • Bertrand-Krajewski, T.-L., Winkler, S., Saracevic, E., Torres, A. & Schaar, H. 2007 Comparison of and uncertainties in raw sewage COD measurements by laboratory techniques and field UV-visible spectrometry. Water Sci. Technol. 56(11), 17-25.
    • (2007) Water Sci. Technol , vol.56 , Issue.11 , pp. 17-25
    • Bertrand-Krajewski, T.-L.1    Winkler, S.2    Saracevic, E.3    Torres, A.4    Schaar, H.5
  • 2
    • 38649110883 scopus 로고
    • Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung - Gruppe H: Bestimmung des chemischen Sauerstoffbedarfs (CSB) -Kurzzeitverfahren (H 43)
    • DIN 38409-H43, Berlin Deutschland, Deutsches Institut für Normung, in German
    • DIN 38409-H43 1980 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung - Gruppe H: Bestimmung des chemischen Sauerstoffbedarfs (CSB) -Kurzzeitverfahren (H 43). Berlin (Deutschland): Deutsches Institut für Normung. [in German].
    • (1980)
  • 3
    • 51649129854 scopus 로고    scopus 로고
    • Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method. Geneva (Switzerland): ISO, p. 18
    • ISO 15705
    • ISO 15705 2002 Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method. Geneva (Switzerland): ISO, p. 18.
    • (2002)
  • 5
    • 42549151515 scopus 로고    scopus 로고
    • Partial Least Squarcs local calibration of a UV-visible spectrometer used for in situ measurements of COD and TSS concentrations in urban drainage systems
    • Torres, A. & Bertrand-Krajewski, J.-L. 2008 Partial Least Squarcs local calibration of a UV-visible spectrometer used for in situ measurements of COD and TSS concentrations in urban drainage systems. Water Sci. Technol. 57(4), 581-588.
    • (2008) Water Sci. Technol , vol.57 , Issue.4 , pp. 581-588
    • Torres, A.1    Bertrand-Krajewski, J.-L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.