메뉴 건너뛰기




Volumn 12, Issue 1, 2008, Pages

Maintenance of tracheal tube cuff pressure: Where are the limits?

Author keywords

[No Author keywords available]

Indexed keywords

ASPIRATION SECRETION; BIOMEDICAL TECHNOLOGY ASSESSMENT; CLINICAL EFFECTIVENESS; COST EFFECTIVENESS ANALYSIS; CUFF; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; HUMAN; INTERMETHOD COMPARISON; NONHUMAN; NOTE; PRIORITY JOURNAL; RISK FACTOR; SECRETION; SUBGLOTTIC SECRETION; TRACHEAL ASPIRATION PROCEDURE; TRACHEAL TUBE CUFF PRESSURE; VENTILATOR ASSOCIATED PNEUMONIA; ANIMAL; DISEASE MODEL; EQUIPMENT DESIGN; INSTRUMENTATION; PRESSURE; SWINE;

EID: 45549091208     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc6194     Document Type: Note
Times cited : (8)

References (16)
  • 1
    • 36549019479 scopus 로고    scopus 로고
    • Continuous control of endotracheal cuff pressure and tracheal wall damage: A randomized controlled animal study
    • 10.1186/cc6142 17915017
    • Nseir S Duguet A Copin MC De Jonckheere J Zhang M Similowski T Marquette CH Continuous control of endotracheal cuff pressure and tracheal wall damage: A randomized controlled animal study Crit Care 2007, 11:R109. 10.1186/cc6142 17915017
    • (2007) Crit Care , vol.11
    • Nseir, S.1    Duguet, A.2    Copin, M.C.3    De Jonckheere, J.4    Zhang, M.5    Similowski, T.6    Marquette, C.H.7
  • 2
    • 2342450732 scopus 로고    scopus 로고
    • Risk factors for ventilator-associated pneumonia: From epidemiology to patient management
    • 10.1086/383039 15095221
    • Bonten MJ Kollef MH Hall JB Risk factors for ventilator-associated pneumonia: From epidemiology to patient management Clin Infect Dis 2004, 38:1141-1149. 10.1086/383039 15095221
    • (2004) Clin Infect Dis , vol.38 , pp. 1141-1149
    • Bonten, M.J.1    Kollef, M.H.2    Hall, J.B.3
  • 3
    • 0033610663 scopus 로고    scopus 로고
    • Supine body position as a risk factor for nosocomial pneumonia in mechanically ventilated patients: A randomised trial
    • 10.1016/S0140-6736(98)12251-1 10584721
    • Drakulovic MB Torres A Bauer TT Nicolas JM Nogue S Ferrer M Supine body position as a risk factor for nosocomial pneumonia in mechanically ventilated patients: A randomised trial Lancet 1999, 354:1851-1858. 10.1016/S0140-6736(98)12251-1 10584721
    • (1999) Lancet , vol.354 , pp. 1851-1858
    • Drakulovic, M.B.1    Torres, A.2    Bauer, T.T.3    Nicolas, J.M.4    Nogue, S.5    Ferrer, M.6
  • 5
    • 33846417278 scopus 로고    scopus 로고
    • Topical chlorhexidine for prevention of ventilator-associated pneumonia: A meta-analysis
    • 10.1097/01.CCM.0000253395.70708.AC 17205028
    • Chlebicki MP Safdar N Topical chlorhexidine for prevention of ventilator-associated pneumonia: A meta-analysis Crit Care Med 2007, 35:595-602. 10.1097/01.CCM.0000253395.70708.AC 17205028
    • (2007) Crit Care Med , vol.35 , pp. 595-602
    • Chlebicki, M.P.1    Safdar, N.2
  • 6
    • 33750267926 scopus 로고    scopus 로고
    • Reduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study
    • 10.1097/01.CCM.0000242154.49632.B0 16957639
    • Rello J Kollef M Diaz E Sandiumenge A del CY Corbella X Zachskorn R Reduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study Crit Care Med 2006, 34:2766-2772. 10.1097/ 01.CCM.0000242154.49632.B0 16957639
    • (2006) Crit Care Med , vol.34 , pp. 2766-2772
    • Rello, J.1    Kollef, M.2    Diaz, E.3    Sandiumenge A. del, C.Y.4    Corbella, X.5    Zachskorn, R.6
  • 7
    • 13644258050 scopus 로고    scopus 로고
    • Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure
    • 535565 15569386 10.1186/1471-2253-4-8
    • Sengupta P Sessler DI Maglinger P Wells S Vogt A Durrani J Wadhwa A Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure BMC Anesthesiol 2004, 4:8. 535565 15569386 10.1186/1471-2253-4-8
    • (2004) BMC Anesthesiol , vol.4 , pp. 8
    • Sengupta, P.1    Sessler, D.I.2    Maglinger, P.3    Wells, S.4    Vogt, A.5    Durrani, J.6    Wadhwa, A.7
  • 9
    • 13644269309 scopus 로고    scopus 로고
    • Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia
    • 10.1164/rccm.200405-644ST 15699079
    • Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia Am J Respir Crit Care Med 2005, 171:388-416. 10.1164/rccm.200405-644ST 15699079
    • (2005) Am J Respir Crit Care Med , vol.171 , pp. 388-416
  • 10
    • 0026682956 scopus 로고
    • A pressure regulator for the cuff of a tracheal tube
    • 10.1111/j.1365-2044.1992.tb02332.x 1626671
    • Miller DM A pressure regulator for the cuff of a tracheal tube Anaesthesia 1992, 47:594-596. 10.1111/j.1365-2044.1992.tb02332.x 1626671
    • (1992) Anaesthesia , vol.47 , pp. 594-596
    • Miller, D.M.1
  • 11
    • 0036798301 scopus 로고    scopus 로고
    • Automatic regulation of the cuff pressure in endotracheally-intubated patients
    • 10.1183/09031936.02.02692001 12412697
    • Farre R Rotger M Ferrer M Torres A Navajas D Automatic regulation of the cuff pressure in endotracheally-intubated patients Eur Respir J 2002, 20:1010-1013. 10.1183/09031936.02.02692001 12412697
    • (2002) Eur Respir J , vol.20 , pp. 1010-1013
    • Farre, R.1    Rotger, M.2    Ferrer, M.3    Torres, A.4    Navajas, D.5
  • 12
    • 34249280606 scopus 로고    scopus 로고
    • Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: A randomized trial
    • 10.1097/01.CCM.0000266686.95843.7D 17452937
    • Valencia M Ferrer M Farre R Navajas D Badia JR Nicolas JM Torres A Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: A randomized trial Crit Care Med 2007, 35:1543-1549. 10.1097/01.CCM.0000266686.95843.7D 17452937
    • (2007) Crit Care Med , vol.35 , pp. 1543-1549
    • Valencia, M.1    Ferrer, M.2    Farre, R.3    Navajas, D.4    Badia, J.R.5    Nicolas, J.M.6    Torres, A.7
  • 13
    • 0030962932 scopus 로고    scopus 로고
    • Leakage of fluid past the tracheal tube cuff in a benchtop model
    • 9175972
    • Young PJ Rollinson M Downward G Henderson S Leakage of fluid past the tracheal tube cuff in a benchtop model Br J Anaesth 1997, 78:557-562. 9175972
    • (1997) Br J Anaesth , vol.78 , pp. 557-562
    • Young, P.J.1    Rollinson, M.2    Downward, G.3    Henderson, S.4
  • 14
    • 0242677653 scopus 로고    scopus 로고
    • Fluid leakage past tracheal tube cuffs: Evaluation of the new Microcuff endotracheal tube
    • 10.1007/s00134-003-1933-6 12923620
    • Dullenkopf A Gerber A Weiss M Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube Intensive Care Med 2003, 29:1849-1853. 10.1007/s00134-003-1933-6 12923620
    • (2003) Intensive Care Med , vol.29 , pp. 1849-1853
    • Dullenkopf, A.1    Gerber, A.2    Weiss, M.3
  • 15
    • 36849046753 scopus 로고    scopus 로고
    • Influence of an endotracheal tube with polyurethane cuff and subglottic drainage on pneumonia
    • 10.1164/rccm.200705-761OC
    • Lorente L Lecuona M Alejandro J Maria M Antonio S Influence of an endotracheal tube with polyurethane cuff and subglottic drainage on pneumonia Am J Respir Crit Care Med 2007, 176:1979-1783. 10.1164/ rccm.200705-761OC
    • (2007) Am J Respir Crit Care Med , vol.176 , pp. 1783-1979
    • Lorente, L.1    Lecuona, M.2    Alejandro, J.3    Maria, M.4    Antonio, S.5
  • 16
    • 5644275044 scopus 로고    scopus 로고
    • Evaluation of continuous aspiration of subglottic secretion in an in vivo study
    • 10.1097/01.CCM.0000142575.86468.9B 15483416
    • Berra L De Marchi L Panigada M Yu ZX Baccarelli A Kolobow T Evaluation of continuous aspiration of subglottic secretion in an in vivo study Crit Care Med 2004, 32:2071-2078. 10.1097/01.CCM.0000142575.86468.9B 15483416
    • (2004) Crit Care Med , vol.32 , pp. 2071-2078
    • Berra, L.1    De Marchi, L.2    Panigada, M.3    Yu, Z.X.4    Baccarelli, A.5    Kolobow, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.