-
1
-
-
24644444644
-
Noninvasive glucose sensing
-
Arnold M A, Small G W. Noninvasive glucose sensing [J]. Anal Chem, 2005, 77(17): 5429-5439.
-
(2005)
Anal Chem
, vol.77
, Issue.17
, pp. 5429-5439
-
-
Arnold, M.A.1
Small, G.W.2
-
2
-
-
6044275963
-
Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
-
Khalil O S. Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium [J]. Diabetes Techno Ther, 2004, 6(5): 660-697.
-
(2004)
Diabetes Techno Ther
, vol.6
, Issue.5
, pp. 660-697
-
-
Khalil, O.S.1
-
3
-
-
33744771301
-
New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring
-
Maruo K, Oota T, Tsurugi M, et al. New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring [J]. Appl Spectrosc, 2006, 60(4): 441-449.
-
(2006)
Appl Spectrosc
, vol.60
, Issue.4
, pp. 441-449
-
-
Maruo, K.1
Oota, T.2
Tsurugi, M.3
-
4
-
-
0031185616
-
Monte Carlo modeling studies of the effect of physiological factors and other analytes on the determination of glucose concentration in vivo by near infrared optical absorption and scattering measurements
-
Qu J, Wilson B C. Monte Carlo modeling studies of the effect of physiological factors and other analytes on the determination of glucose concentration in vivo by near infrared optical absorption and scattering measurements [J]. J Biomed Opt, 1997, 2(3): 319-325.
-
(1997)
J Biomed Opt
, vol.2
, Issue.3
, pp. 319-325
-
-
Qu, J.1
Wilson, B.C.2
-
5
-
-
0036489388
-
Determination of glucose concentration in a scattering medium based on selected wavelengths by use of an overtone absorption band
-
Yoon G, Amerov A K, Jeon K J, et al. Determination of glucose concentration in a scattering medium based on selected wavelengths by use of an overtone absorption band [J]. Appl Opt, 2002, 41(7): 1469-1475.
-
(2002)
Appl Opt
, vol.41
, Issue.7
, pp. 1469-1475
-
-
Yoon, G.1
Amerov, A.K.2
Jeon, K.J.3
-
6
-
-
0242269450
-
In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
-
Maruo K, Tsurugi M, Tamura M, et al. In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy [J]. Appl Spectrosc, 2003, 57(10): 1236-1244.
-
(2003)
Appl Spectrosc
, vol.57
, Issue.10
, pp. 1236-1244
-
-
Maruo, K.1
Tsurugi, M.2
Tamura, M.3
-
7
-
-
0242493198
-
Noninvasive blood glucose assay using a newly developed near-infrared system
-
Maruo K, Tsurugi M, Chin J, et al. Noninvasive blood glucose assay using a newly developed near-infrared system [J]. IEEE J Set Top Quant Elect, 2003, 9(2): 322-330.
-
(2003)
IEEE J Set Top Quant Elect
, vol.9
, Issue.2
, pp. 322-330
-
-
Maruo, K.1
Tsurugi, M.2
Chin, J.3
-
8
-
-
0022723652
-
Error propagation and figures of merit for quantification by solving matrix equations
-
Lorber A. Error propagation and figures of merit for quantification by solving matrix equations [J]. Anal Chem, 1986, 58(6): 1167-1172.
-
(1986)
Anal Chem
, vol.58
, Issue.6
, pp. 1167-1172
-
-
Lorber, A.1
-
9
-
-
0001753960
-
Analytical figures of merit for tensorial calibration
-
Faber K, Lorber A, Kowalski B R. Analytical figures of merit for tensorial calibration [J]. J Chemom, 1997, 11(5): 419-461.
-
(1997)
J Chemom
, vol.11
, Issue.5
, pp. 419-461
-
-
Faber, K.1
Lorber, A.2
Kowalski, B.R.3
-
10
-
-
0033962029
-
Exact presentation of multivariate calibration model as univariate calibration graph
-
Faber N M. Exact presentation of multivariate calibration model as univariate calibration graph [J]. Chemom Intell Lab Syst, 2000, 50(1): 107-114.
-
(2000)
Chemom Intell Lab Syst
, vol.50
, Issue.1
, pp. 107-114
-
-
Faber, N.M.1
-
11
-
-
0033082688
-
Multivariate sensitivity for the interpretation of the effect of spectral pretreatment methods on near-infrared calibration model predictions
-
Faber N M. Multivariate sensitivity for the interpretation of the effect of spectral pretreatment methods on near-infrared calibration model predictions [J]. Anal Chem, 1999, 71(3): 557-565.
-
(1999)
Anal Chem
, vol.71
, Issue.3
, pp. 557-565
-
-
Faber, N.M.1
-
12
-
-
0000479247
-
Net analyte signal calculation in multivariate calibration
-
Lorber A, Faber K, Kowalski B R. Net analyte signal calculation in multivariate calibration [J]. Anal Chem, 1997, 69(8): 1620-1626.
-
(1997)
Anal Chem
, vol.69
, Issue.8
, pp. 1620-1626
-
-
Lorber, A.1
Faber, K.2
Kowalski, B.R.3
-
13
-
-
0034888006
-
Improved calculation of the net analyte signal in inverse multivariate calibration
-
Ferre J, Brown S D, Rius F X. Improved calculation of the net analyte signal in inverse multivariate calibration [J]. J Chemom, 2001, 15(6): 537-553.
-
(2001)
J Chemom
, vol.15
, Issue.6
, pp. 537-553
-
-
Ferre, J.1
Brown, S.D.2
Rius, F.X.3
-
15
-
-
21744447919
-
Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique
-
Xu K, Qiu Q, Jiang J, et al. Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique [J]. Opt Lasers Eng, 2005, 43(10): 1096-1106.
-
(2005)
Opt Lasers Eng
, vol.43
, Issue.10
, pp. 1096-1106
-
-
Xu, K.1
Qiu, Q.2
Jiang, J.3
-
16
-
-
0029045693
-
MCML-Monte Carlo modeling of light transport in multi-layered tissue
-
Wang Lihong, Jacques S L, Zheng Liqiong. MCML-Monte Carlo modeling of light transport in multi-layered tissue [J]. Comput Methods and Programs Biomed, 1995, 47(1): 131-146.
-
(1995)
Comput Methods and Programs Biomed
, vol.47
, Issue.1
, pp. 131-146
-
-
Wang, L.1
Jacques, S.L.2
Zheng, L.3
|