메뉴 건너뛰기




Volumn 23, Issue 4, 2008, Pages 288-293

Avecor trillium oxygenator versus noncoated monolyth oxygenator: A prospective randomized controlled study

Author keywords

[No Author keywords available]

Indexed keywords

HEPARIN; MACROGOL; MARKER; POLYPROPYLENE; SULFATE; SULFONIC ACID DERIVATIVE;

EID: 45449093246     PISSN: 08860440     EISSN: 15408191     Source Type: Journal    
DOI: 10.1111/j.1540-8191.2008.00682.x     Document Type: Article
Times cited : (14)

References (16)
  • 2
    • 0027159961 scopus 로고
    • Blood-surface interactions during cardiopulmonary bypass
    • Edmunds LH Jr. : Blood-surface interactions during cardiopulmonary bypass. J Card Surg 1993 8 : 404 410.
    • (1993) J Card Surg , vol.8 , pp. 404-410
    • Edmunds Jr., L.H.1
  • 3
    • 0032939274 scopus 로고    scopus 로고
    • In vitro evaluation of new surface coatings for extracorporeal circulation
    • Baksaas ST, Videm V, Fosse E, et al : In vitro evaluation of new surface coatings for extracorporeal circulation. Perfusion 1999 14 : 11 19.
    • (1999) Perfusion , vol.14 , pp. 11-19
    • Baksaas, S.T.1    Videm, V.2    Fosse, E.3    Al, E.4
  • 4
    • 0033623890 scopus 로고    scopus 로고
    • Trillium biopassive surface: A new biocompatible treatment for extracorporeal circulation circuits
    • Cazzaniga A, Ranucci M, Isgro G, et al : Trillium biopassive surface: A new biocompatible treatment for extracorporeal circulation circuits. Int J Artif Organs 2000 23 : 319 324.
    • (2000) Int J Artif Organs , vol.23 , pp. 319-324
    • Cazzaniga, A.1    Ranucci, M.2    Isgro, G.3    Al, E.4
  • 5
    • 0032590022 scopus 로고    scopus 로고
    • Effect of trillium biopassive surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass
    • Palanzo DA, Zarro DL, Montesano RM, et al : Effect of trillium biopassive surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass. Perfusion 1999 14 : 473 479.
    • (1999) Perfusion , vol.14 , pp. 473-479
    • Palanzo, D.A.1    Zarro, D.L.2    Montesano, R.M.3    Al, E.4
  • 6
    • 0032707777 scopus 로고    scopus 로고
    • Trillium coating of cardiopulmonary bypass circuits improves biocompatibility
    • Tevaearai HT, Mueller XM, Seigneul I, et al : Trillium coating of cardiopulmonary bypass circuits improves biocompatibility. Int J Artif Organs 1999 22 : 629 634.
    • (1999) Int J Artif Organs , vol.22 , pp. 629-634
    • Tevaearai, H.T.1    Mueller, X.M.2    Seigneul, I.3    Al, E.4
  • 7
    • 2642558047 scopus 로고    scopus 로고
    • Beating heart revascularization with or without cardiopulmonary bypass: Evaluation of inflammatory response in a prospective randomized study
    • Wan IY, Arifi AA, Wan S, et al : Beating heart revascularization with or without cardiopulmonary bypass: Evaluation of inflammatory response in a prospective randomized study. J Thorac Cardiovasc Surg 2004 127 : 1624 1631.
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 1624-1631
    • Wan, I.Y.1    Arifi, A.A.2    Wan, S.3    Al, E.4
  • 8
    • 0027429072 scopus 로고
    • Mechanisms of thrombin generation during surgery and cardiopulmonary bypass
    • Boisclair MD, Lane DA, Philippou H, et al : Mechanisms of thrombin generation during surgery and cardiopulmonary bypass. Blood 1993 82 : 3350 3357.
    • (1993) Blood , vol.82 , pp. 3350-3357
    • Boisclair, M.D.1    Lane, D.A.2    Philippou, H.3    Al, E.4
  • 9
    • 0030271403 scopus 로고    scopus 로고
    • Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility
    • Moen O, Fosse E, Dregelid E, et al : Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility. Ann Thorac Surg 1996 62 : 1134 1140.
    • (1996) Ann Thorac Surg , vol.62 , pp. 1134-1140
    • Moen, O.1    Fosse, E.2    Dregelid, E.3    Al, E.4
  • 10
    • 0029152890 scopus 로고
    • Heparin bonding of bypass circuits reduces cytokine release during cardiopulmonary bypass
    • Steinberg BM, Grossi EA, Schwartz DS, et al : Heparin bonding of bypass circuits reduces cytokine release during cardiopulmonary bypass. Ann Thorac Surg 1995 60 : 525 529.
    • (1995) Ann Thorac Surg , vol.60 , pp. 525-529
    • Steinberg, B.M.1    Grossi, E.A.2    Schwartz, D.S.3    Al, E.4
  • 11
    • 0026538702 scopus 로고
    • Reduced complement activation with heparin-coated oxygenator and tubings in coronary bypass operations
    • Videm V, Svennevig JL, Fosse E, et al : Reduced complement activation with heparin-coated oxygenator and tubings in coronary bypass operations. J Thorac Cardiovasc Surg 1992 103 : 806 813.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 806-813
    • Videm, V.1    Svennevig, J.L.2    Fosse, E.3    Al, E.4
  • 13
    • 0036204951 scopus 로고    scopus 로고
    • Heparin-bonded circuits without a cardiotomy: A description of a minimally invasive technique of cardiopulmonary bypass
    • Lilly KJ, O'Gara PJ, Treanor PR : Heparin-bonded circuits without a cardiotomy: A description of a minimally invasive technique of cardiopulmonary bypass. Perfusion 2002 17 : 95 97.
    • (2002) Perfusion , vol.17 , pp. 95-97
    • Lilly, K.J.1    O'Gara, P.J.2    Treanor, P.R.3
  • 14
    • 0034783119 scopus 로고    scopus 로고
    • Biocompatibility of trillium biopassive surface-coated oxygenator versus uncoated oxygenator during cardiopulmonary bypass
    • Ereth MH, Nuttall GA, Clarke SH, et al : Biocompatibility of trillium biopassive surface-coated oxygenator versus uncoated oxygenator during cardiopulmonary bypass. J Cardiothorac Vasc Anesth 2001 15 : 545 550.
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 545-550
    • Ereth, M.H.1    Nuttall, G.A.2    Clarke, S.H.3    Al, E.4
  • 15
    • 0031864715 scopus 로고    scopus 로고
    • Cardiotomy suction: A major source of brain lipid emboli during cardiopulmonary bypass
    • Brooker RF, Brown WR, Moody DM, et al : Cardiotomy suction: A major source of brain lipid emboli during cardiopulmonary bypass. Ann Thorac Surg 1998 65 : 1651 1655.
    • (1998) Ann Thorac Surg , vol.65 , pp. 1651-1655
    • Brooker, R.F.1    Brown, W.R.2    Moody, D.M.3    Al, E.4
  • 16
    • 0033790341 scopus 로고    scopus 로고
    • Processing scavenged blood with a cell saver reduces cerebral lipid microembolization
    • Kincaid EH, Jones TJ, Stump DA, et al : Processing scavenged blood with a cell saver reduces cerebral lipid microembolization. Ann Thorac Surg 2000 70 : 1296 1300.
    • (2000) Ann Thorac Surg , vol.70 , pp. 1296-1300
    • Kincaid, E.H.1    Jones, T.J.2    Stump, D.A.3    Al, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.