메뉴 건너뛰기




Volumn 24, Issue 9, 2004, Pages 541-543

Comparison of skin sites for estimating serum total bilirubin in in-patients and out-patients: Chest is superior to brow

Author keywords

[No Author keywords available]

Indexed keywords

BILIRUBIN;

EID: 4544348667     PISSN: 07438346     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.jp.7211141     Document Type: Article
Times cited : (16)

References (7)
  • 1
    • 0034243250 scopus 로고    scopus 로고
    • Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia
    • Bhutani VK, Gourley GR, Adler S, Kreamer B, Dalin C, Johnson LH. Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia. Pediatrics 2000;106:E17.
    • (2000) Pediatrics , vol.106
    • Bhutani, V.K.1    Gourley, G.R.2    Adler, S.3    Kreamer, B.4    Dalin, C.5    Johnson, L.H.6
  • 2
    • 0035009870 scopus 로고    scopus 로고
    • Transcutaneous bilirubin measurement: A multicenter evaluation of a new device
    • Rubaltelli FF, Gourley GR, Loskamp N, et al. Transcutaneous bilirubin measurement: a multicenter evaluation of a new device. Pediatrics 2001;107:1264-71.
    • (2001) Pediatrics , vol.107 , pp. 1264-1271
    • Rubaltelli, F.F.1    Gourley, G.R.2    Loskamp, N.3
  • 3
    • 0036196104 scopus 로고    scopus 로고
    • A new transcutaneous bilirubinometer, BiliCheck, used in the neonatal intensive care unit and the maternity ward
    • Ebbesen F, Rasmussen LM, Wimberley PD. A new transcutaneous bilirubinometer, BiliCheck, used in the neonatal intensive care unit and the maternity ward. Acta Paediatr 2002;91:203-11.
    • (2002) Acta Paediatr. , vol.91 , pp. 203-211
    • Ebbesen, F.1    Rasmussen, L.M.2    Wimberley, P.D.3
  • 4
    • 0036178755 scopus 로고    scopus 로고
    • Improved transcutaneous bilirubinometry: Comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population
    • Robertson A, Kazmierczak S, Vos P. Improved transcutaneous bilirubinometry: comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population. J Perinatol 2002;22:12-4.
    • (2002) J. Perinatol. , vol.22 , pp. 12-14
    • Robertson, A.1    Kazmierczak, S.2    Vos, P.3
  • 5
    • 0036305221 scopus 로고    scopus 로고
    • Assessment of a transcutaneous device in the evaluation of neonatal hyperbilirubinemia in a primarily Hispanic population
    • Engle WD, Jackson GL, Sendelbach D, Manning D, Frawley WH. Assessment of a transcutaneous device in the evaluation of neonatal hyperbilirubinemia in a primarily Hispanic population. Pediatrics 2002;110:61-7.
    • (2002) Pediatrics , vol.110 , pp. 61-67
    • Engle, W.D.1    Jackson, G.L.2    Sendelbach, D.3    Manning, D.4    Frawley, W.H.5
  • 7
    • 0026352735 scopus 로고
    • Factors affecting transcutaneous bilirubin measurement: Effect of daylight
    • Yamauchi Y, Yamanouchi I. Factors affecting transcutaneous bilirubin measurement: effect of daylight. Acta Paediatr Jpn 1991;33:658-62.
    • (1991) Acta Paediatr. Jpn. , vol.33 , pp. 658-662
    • Yamauchi, Y.1    Yamanouchi, I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.