메뉴 건너뛰기




Volumn 3, Issue , 2004, Pages

Hemodynamic transfer function estimation with Laguerre polynomials and confidence intervals construction, from functional magnetic resonance imaging (fMRI) data

Author keywords

[No Author keywords available]

Indexed keywords

CONFIDENCE INTERVALS; HEMODYNAMIC RESPONSE FUNCTION (HRF); LAUGUREE POLYNOMIALS;

EID: 4544321833     PISSN: 15206149     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 1
    • 0005387435 scopus 로고
    • Localization of brain function using MRI
    • M.S. Cohen and S.Y. Bookheimer, " Localization of brain function using MRI," Trends Neurosciences vol. 17, pp.208-276, 1994.
    • (1994) Trends Neurosciences , vol.17 , pp. 208-276
    • Cohen, M.S.1    Bookheimer, S.Y.2
  • 3
    • 0029999731 scopus 로고    scopus 로고
    • Linear system analysis of functional MRI in human V1
    • G.M.Boynton, S.A. Engel, G.H. Glover and D.J. Heeger, " Linear system analysis of functional MRI in human V1," J. Neuroscience, vol.16, pp. 4207-4421, 1996.
    • (1996) J. Neuroscience , vol.16 , pp. 4207-4421
    • Boynton, G.M.1    Engel, S.A.2    Glover, G.H.3    Heeger, D.J.4
  • 5
    • 0034813965 scopus 로고    scopus 로고
    • Locally regularized Spatiotemporal modeling and model comparison for functional MRI
    • P. Purdon, V. Solo, R. Weiskoff, E. Brown, " Locally regularized Spatiotemporal modeling and model comparison for functional MRI", Neuroimage 14, pp.912-923, 2001.
    • (2001) Neuroimage , vol.14 , pp. 912-923
    • Purdon, P.1    Solo, V.2    Weiskoff, R.3    Brown, E.4
  • 6
    • 0026157695 scopus 로고
    • System identification using Laguerre models
    • May
    • B. Walberg, " System Identification using Laguerre Models," IEEE Trans. Automatic Control, vol.36, no.5, May 1991.
    • (1991) IEEE Trans. Automatic Control , vol.36 , Issue.5
    • Walberg, B.1
  • 8
    • 0034351115 scopus 로고    scopus 로고
    • Modeling the hemodynamic response in fMRI using smooth FIR filters
    • Dec.
    • C. Goutte, F. Nielson, L.K. Hansen, " Modeling the hemodynamic response in fMRI using smooth FIR filters," IEEE Trans. on Medical Imaging, vol.19, no. 12, Dec. 2000.
    • (2000) IEEE Trans. on Medical Imaging , vol.19 , Issue.12
    • Goutte, C.1    Nielson, F.2    Hansen, L.K.3
  • 9
    • 0033653960 scopus 로고    scopus 로고
    • Estimation and detection of event related fMRI signals with temporally correlated noise: A statistically efficient and unbiased approach
    • M.A. Burock, A.M. Dale, Estimation and detection of event related fMRI signals with temporally correlated noise: a statistically efficient and unbiased approach", Human Brain Mapping vol. 11, 249-260, 2000.
    • (2000) Human Brain Mapping , vol.11 , pp. 249-260
    • Burock, M.A.1    Dale, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.