메뉴 건너뛰기




Volumn 61, Issue 6, 2004, Pages 1391-1395

Freeze-drying applied to radioactive source preparation

Author keywords

Freeze drying; Radioactivity measurement; Source preparation

Indexed keywords

ATMOSPHERIC PRESSURE; CRYSTALLIZATION; DRYING; EVAPORATION; ISOTOPES; RADIATION EFFECTS; RADIOISOTOPES; VALUE ENGINEERING;

EID: 4544300420     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2004.04.006     Document Type: Article
Times cited : (21)

References (19)
  • 1
    • 0024277133 scopus 로고
    • Imaging plate illuminates many fields
    • Amemiya Y., Miyahara J. Imaging plate illuminates many fields. Nature. 336:1988;89-90
    • (1988) Nature , vol.336 , pp. 89-90
    • Amemiya, Y.1    Miyahara, J.2
  • 2
    • 4544304703 scopus 로고
    • De la distillation et de la dessiccation dans le vide à l'aide des basses températures
    • d'Arsonval M., Bordas F. De la distillation et de la dessiccation dans le vide à l'aide des basses températures. C. R. Acad. Sci. 143:1906;567-570
    • (1906) C. R. Acad. Sci. , vol.143 , pp. 567-570
    • D'Arsonval, M.1    Bordas, F.2
  • 5
    • 0036138978 scopus 로고    scopus 로고
    • A new set of electronic modules (NIM standard) for a coincidence system using the pulse mixing method
    • Bouchard J. A new set of electronic modules (NIM standard) for a coincidence system using the pulse mixing method. Appl. Radiat. Isot. 56:2002;269-273
    • (2002) Appl. Radiat. Isot. , vol.56 , pp. 269-273
    • Bouchard, J.1
  • 7
    • 27044447726 scopus 로고
    • The standardization of radioisotopes by the beta-gamma coincidence method using high efficiency detectors
    • Campion P.J. The standardization of radioisotopes by the beta-gamma coincidence method using high efficiency detectors. J. Appl. Radiat. Isot. 4:1959;232-248
    • (1959) J. Appl. Radiat. Isot. , vol.4 , pp. 232-248
    • Campion, P.J.1
  • 8
    • 0023104297 scopus 로고
    • Calculation of extrapolation curves in the 4πβ-γ coincidence method
    • Chauvenet B., Bouchard J., Vatin R. Calculation of extrapolation curves in the 4πβ-γ coincidence method. Appl. Radiat. Isot. 38(1):1987;41-44
    • (1987) Appl. Radiat. Isot. , vol.38 , Issue.1 , pp. 41-44
    • Chauvenet, B.1    Bouchard, J.2    Vatin, R.3
  • 10
    • 2042514797 scopus 로고
    • A routine procedure for 4π proportional counting soft beta particles from solid sources
    • Keith R.L.G., Watt D.E. A routine procedure for 4π proportional counting soft beta particles from solid sources. Nucl. Instrum. Methods. 42:1966;68-70
    • (1966) Nucl. Instrum. Methods , vol.42 , pp. 68-70
    • Keith, R.L.G.1    Watt, D.E.2
  • 13
    • 0015845362 scopus 로고
    • Thin 4π sources on electrosprayed ion exchange resin for radioactivity measurement standardization
    • Lowenthal G.C., Wyllie H.A. Thin 4π sources on electrosprayed ion exchange resin for radioactivity measurement standardization. Int. J. Appl. Radiat. Isot. 24:1973;415-423
    • (1973) Int. J. Appl. Radiat. Isot. , vol.24 , pp. 415-423
    • Lowenthal, G.C.1    Wyllie, H.A.2
  • 14
    • 0003852052 scopus 로고
    • National Council on Radiation Protection and Measurements, NCRP Report No. 58. NCRP Publications, Washington, D.C.
    • NCRP, 1978. A Handbook of Radioactivity Measurements Procedures. National Council on Radiation Protection and Measurements, NCRP Report No. 58. NCRP Publications, Washington, D.C., pp. 196-216.
    • (1978) A Handbook of Radioactivity Measurements Procedures , pp. 196-216
  • 15
    • 0342748772 scopus 로고
    • A new material and techniques for the fabrication and measurement of very thin films for use in 4π counting
    • Pate B.D., Yaffe L. A new material and techniques for the fabrication and measurement of very thin films for use in 4π counting. Can. J. Chem. 33:1954;15-23
    • (1954) Can. J. Chem. , vol.33 , pp. 15-23
    • Pate, B.D.1    Yaffe, L.2
  • 17
    • 0031549170 scopus 로고    scopus 로고
    • A new conducting polymer radioactive source support for 4πβ-γ coincidence counting
    • de Sanoit J., Geffroy B., Rosilio Ch., Hainos D. A new conducting polymer radioactive source support for 4πβ-γ coincidence counting. Nucl. Instrum. Methods B. 131:1997;305-312
    • (1997) Nucl. Instrum. Methods B , vol.131 , pp. 305-312
    • De Sanoit, J.1    Geffroy, B.2    Rosilio, Ch.3    Hainos, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.