메뉴 건너뛰기




Volumn 6, Issue 2, 2004, Pages 85-92

Validity of a portable cardio-respiratory system to collect data in the home environment in patients with obstructive sleep apnea

Author keywords

Cardio respiratory; Home monitoring; Monitoring; Physiologic; Polysomnography; Portable; Sleep; Sleep disordered breathing; Validation studies

Indexed keywords

ADULT; AROUSAL; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION COEFFICIENT; DATA ANALYSIS; FEMALE; HEART FUNCTION; HOME; HUMAN; INTERMETHOD COMPARISON; LABORATORY TEST; MALE; MEDICAL INSTRUMENTATION; NIGHT SLEEP; OXIMETRY; POLYSOMNOGRAPHY; RECORDING; RELIABILITY; RESPIRATORY FUNCTION; SENSITIVITY AND SPECIFICITY; SLEEP APNEA SYNDROME; SLEEP TIME; STATISTICAL SIGNIFICANCE; VALIDATION PROCESS;

EID: 4544286151     PISSN: 13021192     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 0027462562 scopus 로고
    • The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
    • Young, T., et al., The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults. N Engl J Med 1993;328: 1230-1235.
    • (1993) N. Engl. J. Med. , vol.328 , pp. 1230-1235
    • Young, T.1
  • 2
    • 0037142964 scopus 로고    scopus 로고
    • Obstructive sleep apnoea
    • Malhotra, A. and D.P. White, Obstructive sleep apnoea. Lance, 2002;360:237-45.
    • (2002) Lance. , vol.360 , pp. 237-245
    • Malhotra, A.1    White, D.P.2
  • 3
    • 0020574392 scopus 로고
    • Validation of respiratory inductive plethysmography in patients with pulmonary disease
    • Tobin, M.J., et al., Validation of respiratory inductive plethysmography in patients with pulmonary disease. Chest 1983;83:615-20.
    • (1983) Chest , vol.83 , pp. 615-620
    • Tobin, M.J.1
  • 4
    • 0021134883 scopus 로고
    • Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease
    • Gonzalez, H., et al., Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease. Am Rev Respir Dis 1984. 130:171-4.
    • (1984) Am. Rev. Respir. Dis. , vol.130 , pp. 171-174
    • Gonzalez, H.1
  • 6
    • 0026333617 scopus 로고
    • A new method for measuring daytime sleepiness: The Epworth sleepiness scale
    • Johns, M.W., A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep 1991;14:540-5.
    • (1991) Sleep , vol.14 , pp. 540-545
    • Johns, M.W.1
  • 7
    • 0033178851 scopus 로고    scopus 로고
    • Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research
    • American Academy of Sleep Medicine
    • American Academy of Sleep Medicine. Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. Sleep 1999. 22: 667-689.
    • (1999) Sleep , vol.22 , pp. 667-689
  • 9
    • 0024501468 scopus 로고
    • Calibration of respiratory inductive plethysmograph during natural breathing
    • Sackner, M.A., et al., Calibration of respiratory inductive plethysmograph during natural breathing. Journal of Applied Physiology 1989. 66:410-20.
    • (1989) Journal of Applied Physiology , vol.66 , pp. 410-420
    • Sackner, M.A.1
  • 10
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin, L.I., A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J.M. and D.G. Altman, Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0028472690 scopus 로고
    • Use of the sleep laboratory in suspected sleep apnea syndrome: Is one night enough?
    • Mendelson, W. B. Use of the sleep laboratory in suspected sleep apnea syndrome: is one night enough? Cleve Clin J Med 1994;61:299-303.
    • (1994) Cleve Clin. J. Med. , vol.61 , pp. 299-303
    • Mendelson, W.B.1
  • 14
    • 0023689473 scopus 로고
    • Night-to-night variability in sleep apnea and sleep-related periodic leg movements in the elderly
    • Mosko, S. S., Dickel, M. J. & Ashurst, J. Night-to-night variability in sleep apnea and sleep-related periodic leg movements in the elderly. Sleep 1988;11:340-8.
    • (1988) Sleep , vol.11 , pp. 340-348
    • Mosko, S.S.1    Dickel, M.J.2    Ashurst, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.