메뉴 건너뛰기




Volumn 27, Issue 9, 2004, Pages 995-996

The role of implant constraint in revision total knee replacement: Striking the balance

Author keywords

[No Author keywords available]

Indexed keywords

HUMAN; JOINT LIMITATION; KNEE CRUCIATE LIGAMENT; KNEE LIGAMENT; KNEE PROSTHESIS; MECHANICAL STRESS; MEDICAL DECISION MAKING; NOTE; PROSTHESIS FIXATION; REOPERATION; SURGICAL TECHNIQUE; TOTAL KNEE REPLACEMENT; TREATMENT FAILURE; TREATMENT INDICATION;

EID: 4544234957     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: 10.3928/0147-7447-20040901-44     Document Type: Note
Times cited : (3)

References (10)
  • 1
    • 2342604492 scopus 로고    scopus 로고
    • Managing instability in total knee arthroplasty with constrained and linked implants
    • Naudie DD, Rorabeck CH. Managing instability in total knee arthroplasty with constrained and linked implants. Instr Course Lect. 2004; 53:207-215.
    • (2004) Instr. Course Lect. , vol.53 , pp. 207-215
    • Naudie, D.D.1    Rorabeck, C.H.2
  • 2
    • 0036780564 scopus 로고    scopus 로고
    • Rise of the rotating hinge in revision total knee arthroplasty
    • 1020
    • Barrack RL. Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics. 2002; 25:1020,1058.
    • (2002) Orthopedics , vol.25 , pp. 1058
    • Barrack, R.L.1
  • 3
    • 0035159153 scopus 로고    scopus 로고
    • Evolution of the rotating hinge for complex knee arthroplasty
    • Barrack RL. Evolution of the rotating hinge for complex knee arthroplasty. Clin Orthop. 2001; 392:292-299.
    • (2001) Clin. Orthop. , vol.392 , pp. 292-299
    • Barrack, R.L.1
  • 5
    • 0035167929 scopus 로고    scopus 로고
    • Modular, mobile-bearing hinge total knee arthroplasty
    • Jones RE, Barrack RL, Skedros J. Modular, mobile-bearing hinge total knee arthroplasty. Clin Orthop. 2001; 392:306-314.
    • (2001) Clin. Orthop. , vol.392 , pp. 306-314
    • Jones, R.E.1    Barrack, R.L.2    Skedros, J.3
  • 6
    • 0031877930 scopus 로고    scopus 로고
    • Revision total knee arthroplasty: Should tibial stems be cemented or uncemented?
    • Winemaker MJ, Beingessner DM, Rorabeck CH. Revision total knee arthroplasty: should tibial stems be cemented or uncemented? The Knee. 1998; 5:175-181.
    • (1998) The Knee , vol.5 , pp. 175-181
    • Winemaker, M.J.1    Beingessner, D.M.2    Rorabeck, C.H.3
  • 7
    • 0027404885 scopus 로고
    • Cementless revision total knee arthroplasty
    • Whiteside LA. Cementless revision total knee arthroplasty. Clin Orthop. 1993; 286:160-167.
    • (1993) Clin. Orthop. , vol.286 , pp. 160-167
    • Whiteside, L.A.1
  • 8
    • 0031473308 scopus 로고    scopus 로고
    • Revision total knee arthroplasty with a cemented posterior-stabilized or constrained condylar prosthesis: A minimum 3-year and average 5-year follow-up study
    • Peters CL, Hennessey R, Barden RM, Galante JO, Rosenberg AG. Revision total knee arthroplasty with a cemented posterior-stabilized or constrained condylar prosthesis: a minimum 3-year and average 5-year follow-up study. J Arthroplasty. 1997; 12:896-903.
    • (1997) J. Arthroplasty , vol.12 , pp. 896-903
    • Peters, C.L.1    Hennessey, R.2    Barden, R.M.3    Galante, J.O.4    Rosenberg, A.G.5
  • 9
    • 0028826356 scopus 로고
    • Revision total knee arthroplasty with use of modular components with stems inserted without cement
    • Haas SB, Insall JN, Montgomery W III, Windsor RE. Revision total knee arthroplasty with use of modular components with stems inserted without cement. J Bone Joint Surg Am. 1995; 77:1700-1707.
    • (1995) J. Bone Joint Surg. Am. , vol.77 , pp. 1700-1707
    • Haas, S.B.1    Insall, J.N.2    Montgomery III, W.3    Windsor, R.E.4
  • 10
    • 0029028991 scopus 로고
    • Revision knee arthroplasty. The limits of press fit medullary fixation
    • Vince KG, Long W. Revision knee arthroplasty. The limits of press fit medullary fixation. Clin Orthop. 1995; 317:172-177.
    • (1995) Clin. Orthop. , vol.317 , pp. 172-177
    • Vince, K.G.1    Long, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.