메뉴 건너뛰기




Volumn 128, Issue 3, 2008, Pages 343-350

Surface dose measurement in patients and physicians and effective dose estimation in patients during uterine artery embolisation

Author keywords

[No Author keywords available]

Indexed keywords

ANTHROPOMETRY; ARTICLE; BODY SURFACE; CLINICAL ARTICLE; CONTROLLED STUDY; DOSIMETER; DOSIMETRY; FEMALE; FOREARM; HUMAN; HUMAN EXPERIMENT; NORMAL HUMAN; OCCUPATIONAL EXPOSURE; OVARY; PATIENT MONITORING; PHOTOLUMINESCENCE; PHYSICIAN; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; RADIATION MEASUREMENT; RADIATION RESPONSE; THERMOLUMINESCENCE DOSIMETRY; TISSUE LEVEL; UTERINE ARTERY EMBOLIZATION; UTERUS; UTERUS MYOMA;

EID: 45149094235     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncm383     Document Type: Article
Times cited : (10)

References (16)
  • 2
    • 0036721294 scopus 로고    scopus 로고
    • Angiographic classification of ovarian artery-to-uterine artery anastomoses: Initial observation in uterine fibroid embolization
    • Razavi, M. K., Wolanske, K. A., Hwang, G. L., Sze, D. Y., Kee, S. T. and Dake, M. D. Angiographic classification of ovarian artery-to-uterine artery anastomoses: Initial observation in uterine fibroid embolization Radiology 224, 707-712 (2002).
    • (2002) Radiology , vol.224 , pp. 707-712
    • Razavi, M.K.1    Wolanske, K.A.2    Hwang, G.L.3    Sze, D.Y.4    Kee, S.T.5    Dake, M.D.6
  • 4
    • 0030728086 scopus 로고    scopus 로고
    • Preliminary experience with uterine artery embolization for uterine fibroids
    • Goodwin, S. C., Vedanthams, S., McLucas, B., Forno, A. and Perrella. R. Preliminary experience with uterine artery embolization for uterine fibroids. JVIR 8, 517-526 (1997).
    • (1997) JVIR , vol.8 , pp. 517-526
    • Goodwin, S.C.1    Vedanthams, S.2    McLucas, B.3    Forno, A.4    Perrella, R.5
  • 5
    • 0031751507 scopus 로고    scopus 로고
    • Uterine arterial embolization for the management of leiomyomas: Quality-of-life assessment and clinical response
    • Worthington-Kirsch, R. L., Popky, G. L. and Hutchins, F. L. Uterine arterial embolization for the management of leiomyomas: Quality-of-life assessment and clinical response. Radiology 208, 625-629 (1998).
    • (1998) Radiology , vol.208 , pp. 625-629
    • Worthington-Kirsch, R.L.1    Popky, G.L.2    Hutchins, F.L.3
  • 6
    • 0041583566 scopus 로고    scopus 로고
    • International Commission on Radiological Protection, ICRP Publication 85 Oxford: Pergamon Press
    • International Commission on Radiological Protection. Avoidance of radiation injuries ftom medical interventional procedures. ICRP Publication 85 (Oxford: Pergamon Press) (2000).
    • (2000) Avoidance of radiation injuries ftom medical interventional procedures
  • 7
    • 0033962339 scopus 로고    scopus 로고
    • Patient radiation dose associated with uterine artery embolization
    • Nikolic, B., Spies, L. B., Lundsten, M. J. and Abbeara, S. Patient radiation dose associated with uterine artery embolization. Radiology 214, 121-125 (2000).
    • (2000) Radiology , vol.214 , pp. 121-125
    • Nikolic, B.1    Spies, L.B.2    Lundsten, M.J.3    Abbeara, S.4
  • 8
    • 0942277191 scopus 로고    scopus 로고
    • The dose measurement of patients and physicians using a glass dosimeter during endovascular treatment for brain disease
    • Nishizawa, K., Moritake, T., Matsumaru, Y., Tsuboi, K. and Iwai, K. The dose measurement of patients and physicians using a glass dosimeter during endovascular treatment for brain disease. Radiat. Prot. Dosim. 107, 247-252 (2003).
    • (2003) Radiat. Prot. Dosim , vol.107 , pp. 247-252
    • Nishizawa, K.1    Moritake, T.2    Matsumaru, Y.3    Tsuboi, K.4    Iwai, K.5
  • 9
    • 0041961679 scopus 로고    scopus 로고
    • A few remark on photoluninescence dosimetry with high energy X-rays
    • Tsuda, M. A few remark on photoluninescence dosimetry with high energy X-rays. Jpn J. Med. Phys. 20, 131-139 (2000).
    • (2000) Jpn J. Med. Phys , vol.20 , pp. 131-139
    • Tsuda, M.1
  • 10
    • 0942264672 scopus 로고    scopus 로고
    • Revaluation of elemental composition of Mix-DP
    • Hiraoka, T. Revaluation of elemental composition of Mix-DP. Jpn J. Med. Phys. 17, 15-17 (1997).
    • (1997) Jpn J. Med. Phys , vol.17 , pp. 15-17
    • Hiraoka, T.1
  • 11
    • 0019434272 scopus 로고
    • The tissue-equivalence of the Alderson Rando anthropomorphic phantom for X-rays of diagnostic qualities
    • Shrimpton, P. C., Wall, B. F. and Fisher, E. S. The tissue-equivalence of the Alderson Rando anthropomorphic phantom for X-rays of diagnostic qualities. Phys. Med. Biol. 26, 133-139 (1981).
    • (1981) Phys. Med. Biol , vol.26 , pp. 133-139
    • Shrimpton, P.C.1    Wall, B.F.2    Fisher, E.S.3
  • 14
    • 0019450914 scopus 로고
    • Reference Japanese man II. Distribution of strontium in the skeleton and in the mass of mineralired bone
    • Tanaka, G., Kawamura, H. and Nomura, E. Reference Japanese man II. Distribution of strontium in the skeleton and in the mass of mineralired bone. Health Phys. 40, 601 -614 (1981).
    • (1981) Health Phys , vol.40 , pp. 601-614
    • Tanaka, G.1    Kawamura, H.2    Nomura, E.3
  • 15
  • 16
    • 0036877017 scopus 로고    scopus 로고
    • Uterine artery embolization for symptomatic fibroids: Clinical results in 400 women with imaging follow-up
    • Walker, W. J. and Pelage, J. P. Uterine artery embolization for symptomatic fibroids: Clinical results in 400 women with imaging follow-up. BJOG 109, 1262-1272 (2002).
    • (2002) BJOG , vol.109 , pp. 1262-1272
    • Walker, W.J.1    Pelage, J.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.