메뉴 건너뛰기




Volumn 144, Issue 1, 2008, Pages 39-48

Real-time intraoperative assessment of the extrahepatic bile ducts in rats and pigs using invisible near-infrared fluorescent light

Author keywords

[No Author keywords available]

Indexed keywords

FLUORESCENT DYE; INDOCYANINE GREEN; IR 786;

EID: 45049085679     PISSN: 00396060     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.surg.2008.03.017     Document Type: Article
Times cited : (56)

References (48)
  • 1
    • 0027049978 scopus 로고
    • Iatrogenic bile duct injuries. The real incidence and contributing factors-implications for laparoscopic cholecystectomy
    • Caputo L., Aitken D.R., Mackett M.C., and Robles A.E. Iatrogenic bile duct injuries. The real incidence and contributing factors-implications for laparoscopic cholecystectomy. Am Surg 58 (1992) 766-771
    • (1992) Am Surg , vol.58 , pp. 766-771
    • Caputo, L.1    Aitken, D.R.2    Mackett, M.C.3    Robles, A.E.4
  • 2
    • 0025120547 scopus 로고
    • Iatrogenic injury to the bile duct. Who, how, where?
    • discussion 1030-1
    • Moossa A.R., Mayer A.D., and Stabile B. Iatrogenic injury to the bile duct. Who, how, where?. Arch Surg 125 (1990) 1028-1030 discussion 1030-1
    • (1990) Arch Surg , vol.125 , pp. 1028-1030
    • Moossa, A.R.1    Mayer, A.D.2    Stabile, B.3
  • 3
    • 0033511439 scopus 로고    scopus 로고
    • Complications of cholecystectomy: risks of the laparoscopic approach and protective effects of operative cholangiography: a population-based study
    • Fletcher D.R., Hobbs M.S., Tan P., Valinsky L.J., Hockey R.L., Pikora T.J., et al. Complications of cholecystectomy: risks of the laparoscopic approach and protective effects of operative cholangiography: a population-based study. Ann Surg 229 (1999) 449-457
    • (1999) Ann Surg , vol.229 , pp. 449-457
    • Fletcher, D.R.1    Hobbs, M.S.2    Tan, P.3    Valinsky, L.J.4    Hockey, R.L.5    Pikora, T.J.6
  • 4
    • 0142010065 scopus 로고    scopus 로고
    • [Intraoperative cholangiography during laparoscopic cholecystectomy: selective or routine?]
    • Piacentini F., Perri S., Pietrangeli F., Nardi Jr. M., Dalla Torre A., Nicita A., et al. [Intraoperative cholangiography during laparoscopic cholecystectomy: selective or routine?]. G Chir 24 (2003) 123-128
    • (2003) G Chir , vol.24 , pp. 123-128
    • Piacentini, F.1    Perri, S.2    Pietrangeli, F.3    Nardi Jr., M.4    Dalla Torre, A.5    Nicita, A.6
  • 5
    • 33744774204 scopus 로고    scopus 로고
    • Routine versus selective intraoperative cholangiography during laparoscopic cholecystectomy: a survey of 2,130 patients undergoing laparoscopic cholecystectomy
    • Nickkholgh A., Soltaniyekta S., and Kalbasi H. Routine versus selective intraoperative cholangiography during laparoscopic cholecystectomy: a survey of 2,130 patients undergoing laparoscopic cholecystectomy. Surg Endosc 20 (2006) 868-874
    • (2006) Surg Endosc , vol.20 , pp. 868-874
    • Nickkholgh, A.1    Soltaniyekta, S.2    Kalbasi, H.3
  • 6
    • 0029381869 scopus 로고
    • Biliary tract complications of laparoscopic cholecystectomy are detected more frequently with routine intraoperative cholangiography
    • Woods M.S., Traverso L.W., Kozarek R.A., Donohue J.H., Fletcher D.R., Hunter J.G., et al. Biliary tract complications of laparoscopic cholecystectomy are detected more frequently with routine intraoperative cholangiography. Surg Endosc 9 (1995) 1076-1080
    • (1995) Surg Endosc , vol.9 , pp. 1076-1080
    • Woods, M.S.1    Traverso, L.W.2    Kozarek, R.A.3    Donohue, J.H.4    Fletcher, D.R.5    Hunter, J.G.6
  • 8
    • 0034826823 scopus 로고    scopus 로고
    • How do bile duct injuries sustained during laparoscopic cholecystectomy differ from those during open cholecystectomy?
    • Chaudhary A., Manisegran M., Chandra A., Agarwal A.K., and Sachdev A.K. How do bile duct injuries sustained during laparoscopic cholecystectomy differ from those during open cholecystectomy?. J Laparoendosc Adv Surg Tech A 11 (2001) 187-191
    • (2001) J Laparoendosc Adv Surg Tech A , vol.11 , pp. 187-191
    • Chaudhary, A.1    Manisegran, M.2    Chandra, A.3    Agarwal, A.K.4    Sachdev, A.K.5
  • 9
    • 0032249650 scopus 로고    scopus 로고
    • Managing bile duct injury during and after laparoscopic cholecystectomy
    • Inui H., Kwon A.H., and Kamiyama Y. Managing bile duct injury during and after laparoscopic cholecystectomy. J Hepatobiliary Pancreat Surg 5 (1998) 445-449
    • (1998) J Hepatobiliary Pancreat Surg , vol.5 , pp. 445-449
    • Inui, H.1    Kwon, A.H.2    Kamiyama, Y.3
  • 10
    • 0032040076 scopus 로고    scopus 로고
    • Bile duct injury after laparoscopic cholecystectomy. The United States experience
    • MacFadyen Jr. B.V., Vecchio R., Ricardo A.E., and Mathis C.R. Bile duct injury after laparoscopic cholecystectomy. The United States experience. Surg Endosc 12 (1998) 315-321
    • (1998) Surg Endosc , vol.12 , pp. 315-321
    • MacFadyen Jr., B.V.1    Vecchio, R.2    Ricardo, A.E.3    Mathis, C.R.4
  • 11
    • 0034522660 scopus 로고    scopus 로고
    • The clinical utility of spiral CT cholangiography
    • Breen D.J., and Nicholson A.A. The clinical utility of spiral CT cholangiography. Clin Radiol 55 (2000) 733-739
    • (2000) Clin Radiol , vol.55 , pp. 733-739
    • Breen, D.J.1    Nicholson, A.A.2
  • 12
    • 27844514614 scopus 로고    scopus 로고
    • Routine magnetic resonance cholangiopancreatography and intra-operative cholangiogram in the evaluation of common bile duct stones
    • Dalton S.J., Balupuri S., and Guest J. Routine magnetic resonance cholangiopancreatography and intra-operative cholangiogram in the evaluation of common bile duct stones. Ann R Coll Surg Engl 87 (2005) 469-470
    • (2005) Ann R Coll Surg Engl , vol.87 , pp. 469-470
    • Dalton, S.J.1    Balupuri, S.2    Guest, J.3
  • 13
    • 0018149924 scopus 로고
    • [Clinical comparative study between the contrast media Biligram, Endomirabil and Biliscopin (author's transl)]
    • Krueger P. [Clinical comparative study between the contrast media Biligram, Endomirabil and Biliscopin (author's transl)]. Rontgenblatter 31 (1978) 360-364
    • (1978) Rontgenblatter , vol.31 , pp. 360-364
    • Krueger, P.1
  • 14
    • 0019159408 scopus 로고
    • [Quality of roentgenological visualization and tolerance of various intravenous cholegraphic contrast media (author's transl)]
    • Tischendorf P. [Quality of roentgenological visualization and tolerance of various intravenous cholegraphic contrast media (author's transl)]. Rontgenblatter 33 (1980) 581-587
    • (1980) Rontgenblatter , vol.33 , pp. 581-587
    • Tischendorf, P.1
  • 15
    • 0023500133 scopus 로고
    • Adverse reactions to iotroxate at intravenous cholangiography. A prospective clinical investigation and review of the literature
    • Nilsson U. Adverse reactions to iotroxate at intravenous cholangiography. A prospective clinical investigation and review of the literature. Acta Radiol 28 (1987) 571-575
    • (1987) Acta Radiol , vol.28 , pp. 571-575
    • Nilsson, U.1
  • 16
    • 0142230995 scopus 로고    scopus 로고
    • In vivo near-infrared fluorescence imaging
    • Frangioni J.V. In vivo near-infrared fluorescence imaging. Curr Opin Chem Biol 7 (2003) 626-634
    • (2003) Curr Opin Chem Biol , vol.7 , pp. 626-634
    • Frangioni, J.V.1
  • 17
    • 0029978538 scopus 로고    scopus 로고
    • Intraoperative biliary tree imaging with cholyl-lysyl-fluorescein: an experimental study in the rabbit
    • Oddi A., Mills C.O., Custureri F., Di Nicola V., Elias E., and Di Matteo G. Intraoperative biliary tree imaging with cholyl-lysyl-fluorescein: an experimental study in the rabbit. Surg Laparosc Endosc 6 (1996) 198-200
    • (1996) Surg Laparosc Endosc , vol.6 , pp. 198-200
    • Oddi, A.1    Mills, C.O.2    Custureri, F.3    Di Nicola, V.4    Elias, E.5    Di Matteo, G.6
  • 18
    • 0348103721 scopus 로고    scopus 로고
    • An operational near-infrared fluorescence imaging system prototype for large animal surgery
    • De Grand A.M., and Frangioni J.V. An operational near-infrared fluorescence imaging system prototype for large animal surgery. Technol Cancer Res Treat 2 (2003) 553-562
    • (2003) Technol Cancer Res Treat , vol.2 , pp. 553-562
    • De Grand, A.M.1    Frangioni, J.V.2
  • 19
    • 0043132443 scopus 로고    scopus 로고
    • Functional near-infrared fluorescence imaging for cardiac surgery and targeted gene therapy
    • Nakayama A., del Monte F., Hajjar R.J., and Frangioni J.V. Functional near-infrared fluorescence imaging for cardiac surgery and targeted gene therapy. Mol Imaging 1 (2002) 365-377
    • (2002) Mol Imaging , vol.1 , pp. 365-377
    • Nakayama, A.1    del Monte, F.2    Hajjar, R.J.3    Frangioni, J.V.4
  • 20
    • 33845675782 scopus 로고    scopus 로고
    • Image-guided oncologic surgery using invisible light: completed pre-clinical development for sentinel lymph node mapping
    • Tanaka E., Choi H.S., Fujii H., Bawendi M.G., and Frangioni J.V. Image-guided oncologic surgery using invisible light: completed pre-clinical development for sentinel lymph node mapping. Ann Surg Oncol 13 (2006) 1671-1681
    • (2006) Ann Surg Oncol , vol.13 , pp. 1671-1681
    • Tanaka, E.1    Choi, H.S.2    Fujii, H.3    Bawendi, M.G.4    Frangioni, J.V.5
  • 21
    • 0347473808 scopus 로고    scopus 로고
    • Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping
    • Kim S., Lim Y.T., Soltesz E.G., De Grand A.M., Lee J., Nakayama A., et al. Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping. Nat Biotechnol 22 (2004) 93-97
    • (2004) Nat Biotechnol , vol.22 , pp. 93-97
    • Kim, S.1    Lim, Y.T.2    Soltesz, E.G.3    De Grand, A.M.4    Lee, J.5    Nakayama, A.6
  • 23
    • 23044468241 scopus 로고    scopus 로고
    • Engineering InAs(x)P(1-x)/InP/ZnSe III-V alloyed core/shell quantum dots for the near-infrared
    • Kim S.W., Zimmer J.P., Ohnishi S., Tracy J.B., Frangioni J.V., and Bawendi M.G. Engineering InAs(x)P(1-x)/InP/ZnSe III-V alloyed core/shell quantum dots for the near-infrared. J Am Chem Soc 127 (2005) 10526-10532
    • (2005) J Am Chem Soc , vol.127 , pp. 10526-10532
    • Kim, S.W.1    Zimmer, J.P.2    Ohnishi, S.3    Tracy, J.B.4    Frangioni, J.V.5    Bawendi, M.G.6
  • 24
    • 27244435711 scopus 로고    scopus 로고
    • Organic alternatives to quantum dots for intraoperative near-infrared fluorescent sentinel lymph node mapping
    • Ohnishi S., Lomnes S.J., Laurence R.G., Gogbashian A., Mariani G., and Frangioni J.V. Organic alternatives to quantum dots for intraoperative near-infrared fluorescent sentinel lymph node mapping. Mol Imaging 4 (2005) 172-181
    • (2005) Mol Imaging , vol.4 , pp. 172-181
    • Ohnishi, S.1    Lomnes, S.J.2    Laurence, R.G.3    Gogbashian, A.4    Mariani, G.5    Frangioni, J.V.6
  • 26
    • 20144388227 scopus 로고    scopus 로고
    • Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging
    • Parungo C.P., Ohnishi S., Kim S.W., Kim S., Laurence R.G., Soltesz E.G., et al. Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging. J Thorac Cardiovasc Surg 129 (2005) 844-850
    • (2005) J Thorac Cardiovasc Surg , vol.129 , pp. 844-850
    • Parungo, C.P.1    Ohnishi, S.2    Kim, S.W.3    Kim, S.4    Laurence, R.G.5    Soltesz, E.G.6
  • 27
    • 19944383770 scopus 로고    scopus 로고
    • Intraoperative sentinel lymph node mapping of the lung using near-infrared fluorescent quantum dots
    • discussion 269-77
    • Soltesz E.G., Kim S., Laurence R.G., DeGrand A.M., Parungo C.P., Dor D.M., et al. Intraoperative sentinel lymph node mapping of the lung using near-infrared fluorescent quantum dots. Ann Thorac Surg 79 (2005) 269-277 discussion 269-77
    • (2005) Ann Thorac Surg , vol.79 , pp. 269-277
    • Soltesz, E.G.1    Kim, S.2    Laurence, R.G.3    DeGrand, A.M.4    Parungo, C.P.5    Dor, D.M.6
  • 29
    • 33644653853 scopus 로고    scopus 로고
    • Size series of small indium arsenide-zinc selenide core-shell nanocrystals and their application to in vivo imaging
    • Zimmer J.P., Kim S.W., Ohnishi S., Tanaka E., Frangioni J.V., and Bawendi M.G. Size series of small indium arsenide-zinc selenide core-shell nanocrystals and their application to in vivo imaging. J Am Chem Soc 128 (2006) 2526-2527
    • (2006) J Am Chem Soc , vol.128 , pp. 2526-2527
    • Zimmer, J.P.1    Kim, S.W.2    Ohnishi, S.3    Tanaka, E.4    Frangioni, J.V.5    Bawendi, M.G.6
  • 31
    • 35748955203 scopus 로고    scopus 로고
    • Sentinel lymph node mapping of invasive urinary bladder cancer in animal models using invisible light
    • Knapp D.W., Adams L.G., Degrand A.M., Niles J.D., Ramos-Vara J.A., Weil A.B., et al. Sentinel lymph node mapping of invasive urinary bladder cancer in animal models using invisible light. Eur Urol (2007)
    • (2007) Eur Urol
    • Knapp, D.W.1    Adams, L.G.2    Degrand, A.M.3    Niles, J.D.4    Ramos-Vara, J.A.5    Weil, A.B.6
  • 34
    • 31344447699 scopus 로고    scopus 로고
    • High-affinity near-infrared fluorescent small-molecule contrast agents for in vivo imaging of prostate-specific membrane antigen
    • Humblet V., Lapidus R., Williams L.R., Tsukamoto T., Rojas C., Majer P., et al. High-affinity near-infrared fluorescent small-molecule contrast agents for in vivo imaging of prostate-specific membrane antigen. Mol Imaging 4 (2005) 448-462
    • (2005) Mol Imaging , vol.4 , pp. 448-462
    • Humblet, V.1    Lapidus, R.2    Williams, L.R.3    Tsukamoto, T.4    Rojas, C.5    Majer, P.6
  • 35
    • 0142027300 scopus 로고    scopus 로고
    • Near-infrared fluorescence imaging of microcalcification in an animal model of breast cancer
    • Lenkinski R.E., Ahmed M., Zaheer A., Frangioni J.V., and Goldberg S.N. Near-infrared fluorescence imaging of microcalcification in an animal model of breast cancer. Acad Radiol 10 (2003) 1159-1164
    • (2003) Acad Radiol , vol.10 , pp. 1159-1164
    • Lenkinski, R.E.1    Ahmed, M.2    Zaheer, A.3    Frangioni, J.V.4    Goldberg, S.N.5
  • 37
    • 33748482210 scopus 로고    scopus 로고
    • Intraoperative detection of cell injury and cell death with an 800 nm near-infrared fluorescent Annexin V derivative
    • Ohnishi S., Vanderheyden J.L., Tanaka E., Patel B., De Grand A.M., Laurence R.G., et al. Intraoperative detection of cell injury and cell death with an 800 nm near-infrared fluorescent Annexin V derivative. Am J Transplant 6 (2006) 2321-2331
    • (2006) Am J Transplant , vol.6 , pp. 2321-2331
    • Ohnishi, S.1    Vanderheyden, J.L.2    Tanaka, E.3    Patel, B.4    De Grand, A.M.5    Laurence, R.G.6
  • 38
    • 33750430329 scopus 로고    scopus 로고
    • Radiolabeled and near-infrared fluorescent fibrinogen derivatives create a system for the identification and repair of obscure gastrointestinal bleeding
    • Ohnishi S., Garfein E.S., Karp S.J., and Frangioni J.V. Radiolabeled and near-infrared fluorescent fibrinogen derivatives create a system for the identification and repair of obscure gastrointestinal bleeding. Surgery 140 (2006) 785-792
    • (2006) Surgery , vol.140 , pp. 785-792
    • Ohnishi, S.1    Garfein, E.S.2    Karp, S.J.3    Frangioni, J.V.4
  • 39
    • 33846101945 scopus 로고    scopus 로고
    • Localization and quantification of platelet-rich thrombi in large blood vessels with near-infrared fluorescence imaging
    • Flaumenhaft R., Tanaka E., Graham G.J., De Grand A.M., Laurence R.G., Hoshino K., et al. Localization and quantification of platelet-rich thrombi in large blood vessels with near-infrared fluorescence imaging. Circulation 115 (2007) 84-93
    • (2007) Circulation , vol.115 , pp. 84-93
    • Flaumenhaft, R.1    Tanaka, E.2    Graham, G.J.3    De Grand, A.M.4    Laurence, R.G.5    Hoshino, K.6
  • 41
    • 0024382574 scopus 로고
    • Adverse reactions to indocyanine green: a case report and a review of the literature
    • Benya R., Quintana J., and Brundage B. Adverse reactions to indocyanine green: a case report and a review of the literature. Cathet Cardiovasc Diagn 17 (1989) 231-233
    • (1989) Cathet Cardiovasc Diagn , vol.17 , pp. 231-233
    • Benya, R.1    Quintana, J.2    Brundage, B.3
  • 43
    • 33847088700 scopus 로고
    • Absorption and fluorescence properties of cyanine dyes
    • Benson C., and Kues H.A. Absorption and fluorescence properties of cyanine dyes. J Chem Eng Data 22 (1977) 379-383
    • (1977) J Chem Eng Data , vol.22 , pp. 379-383
    • Benson, C.1    Kues, H.A.2
  • 44
    • 33644748269 scopus 로고    scopus 로고
    • Improved optical sub-systems for intraoperative near-infrared fluorescence imaging
    • Gioux S., De Grand A.M., Lee D.S., Yazdanfarc S., Idoine J.D., Lomnes S.J., et al. Improved optical sub-systems for intraoperative near-infrared fluorescence imaging. Proc of SPIE 6009 (2005) 39-48
    • (2005) Proc of SPIE , vol.6009 , pp. 39-48
    • Gioux, S.1    De Grand, A.M.2    Lee, D.S.3    Yazdanfarc, S.4    Idoine, J.D.5    Lomnes, S.J.6
  • 46
    • 45049088342 scopus 로고    scopus 로고
    • An HPLC/mass spectrometry platform for the development of multimodality contrast agents and targeted therapeutics: prostate-specific membrane antigen small molecule derivatives
    • Humblet V M.P., and Frangioni J.V. An HPLC/mass spectrometry platform for the development of multimodality contrast agents and targeted therapeutics: prostate-specific membrane antigen small molecule derivatives. Contrast Med Mol Imag 4 (2006) 448-462
    • (2006) Contrast Med Mol Imag , vol.4 , pp. 448-462
    • Humblet V, M.P.1    Frangioni, J.V.2
  • 47
    • 35148844070 scopus 로고    scopus 로고
    • Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence
    • Tanaka E., Ohnishi S., Laurence R.G., Choi H.S., Humblet V., and Frangioni J.V. Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence. J Urol 178 (2007) 2197-2202
    • (2007) J Urol , vol.178 , pp. 2197-2202
    • Tanaka, E.1    Ohnishi, S.2    Laurence, R.G.3    Choi, H.S.4    Humblet, V.5    Frangioni, J.V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.