메뉴 건너뛰기




Volumn 53, Issue 3, 2008, Pages 130-137

Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: A biomechanical study;Osteosynthese am proximalen humerus mittels winkelstabiler platte oder doppelplatte: Eine vergleichende biomechanische untersuchung

Author keywords

Angle fixed osteosynthesis; Biomechanics; Fracture; Humerus; Plate fixation

Indexed keywords

AXIAL LOADS; BIOMECHANICS; COATING TECHNIQUES; COMPUTER NETWORKS; FRACTURE FIXATION; IMPLANTS (SURGICAL); LOADING; LOADS (FORCES); MECHANICS; PETROLEUM DEPOSITS; PETROLEUM RESERVOIRS; PLATES (STRUCTURAL COMPONENTS);

EID: 44949262177     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/BMT.2008.018     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 0035028278 scopus 로고    scopus 로고
    • Die Osteosynthese der dislozierten Humeruskopffraktur mit der winkelstabilen proximalen Oberarmplatte.
    • Bartsch S, Hullmann S, Hillrichs B, Giers R, Echtermeyer V. Die Osteosynthese der dislozierten Humeruskopffraktur mit der winkelstabilen proximalen Oberarmplatte. Akt Traumatol 2001; 31: 64-71.
    • (2001) Akt Traumatol , vol.31 , pp. 64-71
    • Bartsch, S.1    Hullmann, S.2    Hillrichs, B.3    Giers, R.4    Echtermeyer, V.5
  • 2
    • 33644524124 scopus 로고    scopus 로고
    • Assessment of bone quality in the proximal humerus by measurement of the contralateral site: A cadaveric analysis
    • Diederichs G, Korner J, Goldhahn J, Linke B. Assessment of bone quality in the proximal humerus by measurement of the contralateral site: a cadaveric analysis. Arch Orthop Trauma Surg 2006; 126: 93-100.
    • (2006) Arch Orthop Trauma Surg , vol.126 , pp. 93-100
    • Diederichs, G.1    Korner, J.2    Goldhahn, J.3    Linke, B.4
  • 3
    • 0028156028 scopus 로고
    • Open reduction and internal fixation of three- and four-part fractures of the proximal humerus
    • Esser R. Open reduction and internal fixation of three- and four-part fractures of the proximal humerus. Clin Orthop 1994; 299: 244-255.
    • (1994) Clin Orthop , vol.299 , pp. 244-255
    • Esser, R.1
  • 4
    • 44949249136 scopus 로고    scopus 로고
    • Die menschliche Tibia im Torsionsversuch. Inauguraldissertation
    • Davos
    • Grütter R. Die menschliche Tibia im Torsionsversuch. Inauguraldissertation. Davos, Schweiz: AO-Forschungsinstitut: Davos 1996.
    • (1996) Davos, Schweiz: AO-Forschungsinstitut
    • Grütter, R.1
  • 5
    • 33645046408 scopus 로고    scopus 로고
    • New trends in the treatment of proximal humerus fractures
    • Helmy N, Hintermann B. New trends in the treatment of proximal humerus fractures. Clin Orthop 2006; 442: 100-108.
    • (2006) Clin Orthop , vol.442 , pp. 100-108
    • Helmy, N.1    Hintermann, B.2
  • 6
    • 26944483556 scopus 로고    scopus 로고
    • Fractures of the proximal humerus in osteoporotic bone
    • Hertel R. Fractures of the proximal humerus in osteoporotic bone. Osteoporos Int 2005; 16: S65-S72.
    • (2005) Osteoporos Int , vol.16
    • Hertel, R.1
  • 7
    • 44949194984 scopus 로고    scopus 로고
    • Rotationsstabilität von verschiedenen Osteosynthesetechniken bei proximalen Humerusfrakturen.
    • Hersche O, Trentz O. Rotationsstabilität von verschiedenen Osteosynthesetechniken bei proximalen Humerusfrakturen. Swiss Surgery 1996; 2 (Suppl): 24.
    • (1996) Swiss Surgery , vol.2 , Issue.SUPPL. , pp. 24
    • Hersche, O.1    Trentz, O.2
  • 8
    • 0032816596 scopus 로고    scopus 로고
    • Plate fixation of proximal humeral fractures with indirect reduction: Surgical technique and results utilizing three shoulder scores
    • Hessmann MH, Baumgaertel F, Gehling H, Klingelhoeffer I, Gotzen L. Plate fixation of proximal humeral fractures with indirect reduction: surgical technique and results utilizing three shoulder scores. Injury 1999; 30: 453-462.
    • (1999) Injury , vol.30 , pp. 453-462
    • Hessmann, M.H.1    Baumgaertel, F.2    Gehling, H.3    Klingelhoeffer, I.4    Gotzen, L.5
  • 9
    • 22544468510 scopus 로고    scopus 로고
    • Locked plate fixation and intramedullary nailing for proximal humeral fractures: A biomechanical evaluation
    • Hessmann MH, Sternstein W, Hansen M, Krummenauer F, Fischer T, Rommens PM. Locked plate fixation and intramedullary nailing for proximal humeral fractures: a biomechanical evaluation. J Trauma 2005; 58:1194-1201.
    • (2005) J Trauma , vol.58 , pp. 1194-1201
    • Hessmann, M.H.1    Sternstein, W.2    Hansen, M.3    Krummenauer, F.4    Fischer, T.5    Rommens, P.M.6
  • 10
    • 11144248954 scopus 로고    scopus 로고
    • Sind winkelstabile Plattensysteme mit elastischen Eigenschaften für die Stabilisierung der Oberarmkopffraktur vorteilhaft?
    • Hessmann MH, Sternstein W, Mehler D, Korner J, Hofmann A, Rommens PM. Sind winkelstabile Plattensysteme mit elastischen Eigenschaften für die Stabilisierung der Oberarmkopffraktur vorteilhaft? Biomed Tech 2004; 49: 345-350.
    • (2004) Biomed Tech , vol.49 , pp. 345-350
    • Hessmann, M.H.1    Sternstein, W.2    Mehler, D.3    Korner, J.4    Hofmann, A.5    Rommens, P.M.6
  • 11
    • 0033646587 scopus 로고    scopus 로고
    • Rigid internal fixation of fractures of the proximal humerus in older patients
    • Hintermann B, Trouillier HH, Schäfer D. Rigid internal fixation of fractures of the proximal humerus in older patients. J Bone Joint Surg 2000; 82B: 1107-1112.
    • (2000) J Bone Joint Surg , vol.82 B , pp. 1107-1112
    • Hintermann, B.1    Trouillier, H.H.2    Schäfer, D.3
  • 12
    • 0032151553 scopus 로고    scopus 로고
    • Semitubular blade plate fixation in proximal humeral fractures: A biomechanical study in a cadaveric model
    • Instrum K, Fennell C, Shrive N, Damson E, Sonnabend D, Hollinshead R. Semitubular blade plate fixation in proximal humeral fractures: a biomechanical study in a cadaveric model. J Shoulder Elbow Surg 1998; 7: 462-466.
    • (1998) J Shoulder Elbow Surg , vol.7 , pp. 462-466
    • Instrum, K.1    Fennell, C.2    Shrive, N.3    Damson, E.4    Sonnabend, D.5    Hollinshead, R.6
  • 13
    • 0030225744 scopus 로고    scopus 로고
    • Biomechanical investigations of the glenohumeral joint
    • Itoi E, Hsu HC, An KN. Biomechanical investigations of the glenohumeral joint. J Shoulder Elbow Surg 1996; 5: 407-424.
    • (1996) J Shoulder Elbow Surg , vol.5 , pp. 407-424
    • Itoi, E.1    Hsu, H.C.2    An, K.N.3
  • 14
    • 10744229279 scopus 로고    scopus 로고
    • Die proximale Humerusfraktur im hohen Lebensalter - Versorgung mit der winkelstabilen Plattenosteosynthese.
    • Köstler W, Strohm PC, Südkamp NP. Die proximale Humerusfraktur im hohen Lebensalter - Versorgung mit der winkelstabilen Plattenosteosynthese. Chirurg 2003; 74: 985-989.
    • (2003) Chirurg , vol.74 , pp. 985-989
    • Köstler, W.1    Strohm, P.C.2    Südkamp, N.P.3
  • 16
    • 0030004494 scopus 로고    scopus 로고
    • Surgical neck fractures of the proximal humerus: A laboratory evaluation of ten fixation techniques
    • Koval KJ, Blair B, Takei R, Kummer FJ, Zuckerman JD. Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques. J Trauma 1996; 40: 778-783.
    • (1996) J Trauma , vol.40 , pp. 778-783
    • Koval, K.J.1    Blair, B.2    Takei, R.3    Kummer, F.J.4    Zuckerman, J.D.5
  • 18
    • 0038338590 scopus 로고    scopus 로고
    • Proximal humeral fractures: How stiff should an implant be?
    • Lill H, Hepp P, Korner J, et al. Proximal humeral fractures: how stiff should an implant be? Arch Orthop Trauma Surg 2003; 123: 74-81.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 74-81
    • Lill, H.1    Hepp, P.2    Korner, J.3
  • 19
    • 0037279050 scopus 로고    scopus 로고
    • Humeruskopffrakturen - winkelstabile Plattenosteosynthese.
    • Lungershausen W, Bach O, Lorenz CO. Humeruskopffrakturen - winkelstabile Plattenosteosynthese. Zentralbl Chir 2003; 128: 28-33.
    • (2003) Zentralbl Chir , vol.128 , pp. 28-33
    • Lungershausen, W.1    Bach, O.2    Lorenz, C.O.3
  • 20
    • 0034777725 scopus 로고    scopus 로고
    • Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures
    • Marti A, Fankhauser C, Frenk A, Cordey J, Gasser B. Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures. J Orthop Trauma 2001; 15: 482-487.
    • (2001) J Orthop Trauma , vol.15 , pp. 482-487
    • Marti, A.1    Fankhauser, C.2    Frenk, A.3    Cordey, J.4    Gasser, B.5
  • 21
    • 0035514247 scopus 로고    scopus 로고
    • Die winkel- und rotationsstabile Osteosynthese proximaler Humerusfrakturen mit der Humerus-Fixateurplatte.
    • Mückter H, Herzog L, Becker M, Vogel W, Meeder PJ, Buchholz J. Die winkel- und rotationsstabile Osteosynthese proximaler Humerusfrakturen mit der Humerus-Fixateurplatte. Chirurg 2001; 72: 1327-1335.
    • (2001) Chirurg , vol.72 , pp. 1327-1335
    • Mückter, H.1    Herzog, L.2    Becker, M.3    Vogel, W.4    Meeder, P.J.5    Buchholz, J.6
  • 24
    • 0024505109 scopus 로고
    • Open reduction and internal fixation of three-part fractures of the proximal humerus
    • Savoie FH, Geissler WB, Vander Griend RA. Open reduction and internal fixation of three-part fractures of the proximal humerus. Orthopedics 1989; 12: 124-129.
    • (1989) Orthopedics , vol.12 , pp. 124-129
    • Savoie, F.H.1    Geissler, W.B.2    Vander Griend, R.A.3
  • 25
    • 33748957058 scopus 로고    scopus 로고
    • Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: Comparison using cadaveric and synthetic humeri
    • Siffri PC, Peindl RD, Coley ER, Norton J, Connor PM, Kellam JF. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma 2006; 20: 547-554.
    • (2006) J Orthop Trauma , vol.20 , pp. 547-554
    • Siffri, P.C.1    Peindl, R.D.2    Coley, E.R.3    Norton, J.4    Connor, P.M.5    Kellam, J.F.6
  • 26
    • 0029664841 scopus 로고    scopus 로고
    • Proximale Humerusmehrfragmentfrakturen - Misserfolge nach T-Plattenosteosynthese.
    • Speck M, Lang FJH, Regazzoni P. Proximale Humerusmehrfragmentfrakturen - Misserfolge nach T-Plattenosteosynthese. Swiss Surg 1996; 2: 51-56.
    • (1996) Swiss Surg , vol.2 , pp. 51-56
    • Speck, M.1    Lang, F.J.H.2    Regazzoni, P.3
  • 27
    • 0037351781 scopus 로고    scopus 로고
    • Internal fixation of displaced proximal humeral fractrues with two one-third tubular plates
    • Wanner G, Wanner-Schmid E, Hersche O, von Smekal A, Trentz O, Ertel W. Internal fixation of displaced proximal humeral fractrues with two one-third tubular plates. J Trauma 2003; 54: 536-544.
    • (2003) J Trauma , vol.54 , pp. 536-544
    • Wanner, G.1    Wanner-Schmid, E.2    Hersche, O.3    von Smekal, A.4    Trentz, O.5    Ertel, W.6
  • 28
    • 0031179758 scopus 로고    scopus 로고
    • Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation
    • Wheeler DL, Colville MR. Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation. J Orthop Trauma 1997; 11: 363-367.
    • (1997) J Orthop Trauma , vol.11 , pp. 363-367
    • Wheeler, D.L.1    Colville, M.R.2
  • 29
    • 0036844148 scopus 로고    scopus 로고
    • Open reduction and internal fixation of three- and fourpart fractures of the proximal part of the humerus
    • Wijgman AJ, Roolker W, Patt TW, Raaymakers ELFB, Marti RK. Open reduction and internal fixation of three- and fourpart fractures of the proximal part of the humerus. J Bone Joint Surg 2002; 84A: 1919-1925.
    • (2002) J Bone Joint Surg , vol.84 A , pp. 1919-1925
    • Wijgman, A.J.1    Roolker, W.2    Patt, T.W.3    Raaymakers, E.L.F.B.4    Marti, R.K.5
  • 30
    • 0031226203 scopus 로고    scopus 로고
    • The influence of intramedullary fixation on figure-of-eight wiring for surgical neck fractures of the proximal humerus: A biomechanical comparison
    • Williams GR, Copley LA, Ianotti JP, Lisser SP. The influence of intramedullary fixation on figure-of-eight wiring for surgical neck fractures of the proximal humerus: a biomechanical comparison. J Shoulder Elbow Surg 1997; 6: 423-428.
    • (1997) J Shoulder Elbow Surg , vol.6 , pp. 423-428
    • Williams, G.R.1    Copley, L.A.2    Ianotti, J.P.3    Lisser, S.P.4
  • 31
    • 0029058830 scopus 로고
    • Die 95°-Kondylenplatte für kleinwüchsige Erwachsene und Jugendliche zur Stabilisierung proximaler Humerusfrakturen.
    • Winter E, Volkmann R, Eingartner C, Weller S. Die 95°-Kondylenplatte für kleinwüchsige Erwachsene und Jugendliche zur Stabilisierung proximaler Humerusfrakturen. Akt Traumatol 1995; 25: 85-87.
    • (1995) Akt Traumatol , vol.25 , pp. 85-87
    • Winter, E.1    Volkmann, R.2    Eingartner, C.3    Weller, S.4
  • 32
    • 0012617406 scopus 로고    scopus 로고
    • Erste klinische Erfahrungen mit einem Fixateur interne am Humerus.
    • Wurm M, Wolter D, Wenzl M, Jessel M. Erste klinische Erfahrungen mit einem Fixateur interne am Humerus. Trauma Berufskrankh 1999; 1: 370-374.
    • (1999) Trauma Berufskrankh , vol.1 , pp. 370-374
    • Wurm, M.1    Wolter, D.2    Wenzl, M.3    Jessel, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.