메뉴 건너뛰기




Volumn 55, Issue 6, 2008, Pages 1355-1362

Vibrating interventional device detection using real-time 3-D color Doppler

Author keywords

[No Author keywords available]

Indexed keywords

(OTDR) TECHNOLOGY; ANALYTICAL MODELLING; ATRIAL SEPTAL PUNCTURE NEEDLE; CLINICAL PROCEDURES; COLOR DOPPLER; DEVICE DETECTION; ENDOMYOCARDIAL BIOPSY; IN-VIVO; INTERVENTIONAL; MINIMALLY INVASIVE SURGERY (MIS); PHYSIOLOGICAL MOTION; RADIATION EXPOSURES; RADIO FREQUENCY (RF); REAL TIME 3 D (THREE DIMENSION); SOFT TISSUES; ULTRASOUND (US) IMAGES; ULTRASOUND SYSTEMS; VASCULAR GRAFTING; VIBRATING DEVICES; WATER TANK EXPERIMENTS;

EID: 44949192736     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2008.798     Document Type: Article
Times cited : (44)

References (36)
  • 2
    • 2342488846 scopus 로고    scopus 로고
    • New techniques in image-guided percutaneous biopsy
    • S. Gupta, "New techniques in image-guided percutaneous biopsy, " Cardiovasc. Intervent. Radiol., vol. 27, pp. 91-104, 2004.
    • (2004) Cardiovasc. Intervent. Radiol , vol.27 , pp. 91-104
    • Gupta, S.1
  • 3
    • 0035383719 scopus 로고    scopus 로고
    • In-vitro visualization of biopsy needles with ultrasound: A comparative study of standard and echogenic needles using an ultrasound phantom
    • R. E. Hopkins and M. Bradley, "In-vitro visualization of biopsy needles with ultrasound: A comparative study of standard and echogenic needles using an ultrasound phantom, " Clin. Radiol., vol. 56, pp. 499-502, 2001.
    • (2001) Clin. Radiol , vol.56 , pp. 499-502
    • Hopkins, R.E.1    Bradley, M.2
  • 5
    • 0021463080 scopus 로고
    • Ultrasonic stylets for needles and catheters
    • W. N. McDicken and T. Andersen, "Ultrasonic stylets for needles and catheters, " Ultrasound Med. Biol., vol. 10, pp. 499-507, 1984.
    • (1984) Ultrasound Med. Biol , vol.10 , pp. 499-507
    • McDicken, W.N.1    Andersen, T.2
  • 7
    • 0031102706 scopus 로고    scopus 로고
    • A system for ultrasonic beaconguidance of catheters and other minimally-invasive medical devices
    • D. Vilkomerson and D. Lyons, "A system for ultrasonic beaconguidance of catheters and other minimally-invasive medical devices, " IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, pp. 496-504, 1997.
    • (1997) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.44 , pp. 496-504
    • Vilkomerson, D.1    Lyons, D.2
  • 8
    • 0030779353 scopus 로고    scopus 로고
    • A system for ultrasonic beaconguidance of catheters and other minimally-invasive medical devices
    • D. Vilkomerson and D. Lyons, "A system for ultrasonic beaconguidance of catheters and other minimally-invasive medical devices, " IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, pp. 27-35, 1997.
    • (1997) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.44 , pp. 27-35
    • Vilkomerson, D.1    Lyons, D.2
  • 9
    • 0035200465 scopus 로고    scopus 로고
    • Locating a catheter transducer in a three-dimensional ultrasound imaging field
    • C. L. Merdes and P. D. Wolf, "Locating a catheter transducer in a three-dimensional ultrasound imaging field, " IEEE Trans. Biomed. Eng., vol. 48, pp. 1444-1452, 2001.
    • (2001) IEEE Trans. Biomed. Eng , vol.48 , pp. 1444-1452
    • Merdes, C.L.1    Wolf, P.D.2
  • 10
    • 0038799807 scopus 로고    scopus 로고
    • Color Doppler sonographically guided transthoracic needle aspiration of lung and mediastinal masses
    • M. Gorguner, F. Misirlioglu, P. Polat, H. Kaynar, L. Saglam, A. Mirici, and S. Suma, "Color Doppler sonographically guided transthoracic needle aspiration of lung and mediastinal masses, " J. Ultrasound Med., vol. 22, pp. 703-708, 2003.
    • (2003) J. Ultrasound Med , vol.22 , pp. 703-708
    • Gorguner, M.1    Misirlioglu, F.2    Polat, P.3    Kaynar, H.4    Saglam, L.5    Mirici, A.6    Suma, S.7
  • 12
    • 17644376215 scopus 로고    scopus 로고
    • Real-time 3-D color flow Doppler for guidance of vibrating interventional devices
    • M. P. Fronheiser, P. D. Wolf, S. F. Idriss, R. C. Nelson, W. Lee, and S. W. Smith, "Real-time 3-D color flow Doppler for guidance of vibrating interventional devices," Ultrason. Imag., vol. 26, pp. 173-184, 2004.
    • (2004) Ultrason. Imag , vol.26 , pp. 173-184
    • Fronheiser, M.P.1    Wolf, P.D.2    Idriss, S.F.3    Nelson, R.C.4    Lee, W.5    Smith, S.W.6
  • 13
    • 0036525595 scopus 로고    scopus 로고
    • Guidance of cardiac pacemaker leads using real time 3D ultrasound: Feasibility studies
    • S. W. Smith, R. C. Booi, E. D. Light, C. L. Merdes, and P. D. Wolf, "Guidance of cardiac pacemaker leads using real time 3D ultrasound: Feasibility studies, " Ultrason. Imag., vol. 24, pp. 119-128, 2002.
    • (2002) Ultrason. Imag , vol.24 , pp. 119-128
    • Smith, S.W.1    Booi, R.C.2    Light, E.D.3    Merdes, C.L.4    Wolf, P.D.5
  • 14
    • 0026128882 scopus 로고
    • High-speed ultrasound volumetric imaging-system. 1. Transducer design and beam steering
    • S. W. Smith, H. G. Pavy, and O. T. von Ramm, "High-speed ultrasound volumetric imaging-system. 1. Transducer design and beam steering, " IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 38, pp. 100-108, 1991.
    • (1991) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.38 , pp. 100-108
    • Smith, S.W.1    Pavy, H.G.2    von Ramm, O.T.3
  • 15
    • 0026128878 scopus 로고
    • High-speed ultrasound volumetric imaging-system. 2. Parallel processing and image display
    • O. T. von Ramm, S. W. Smith, and H. G. Pavy, "High-speed ultrasound volumetric imaging-system. 2. Parallel processing and image display, " IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 38, pp. 109-115, 1991.
    • (1991) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.38 , pp. 109-115
    • von Ramm, O.T.1    Smith, S.W.2    Pavy, H.G.3
  • 17
    • 0036511288 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography
    • G. Camarano, M. Jones, R. Z. Freidlin, and J. A. Panza, "Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography, " J. Am. Soc. Echocardiogr., vol. 15, pp. 206-213, 2002.
    • (2002) J. Am. Soc. Echocardiogr , vol.15 , pp. 206-213
    • Camarano, G.1    Jones, M.2    Freidlin, R.Z.3    Panza, J.A.4
  • 18
    • 0035186021 scopus 로고    scopus 로고
    • Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: A comparison with fluoroscopy
    • C. J. McCreery, M. McCulloch, M. Ahmad, and C. R. deFilippi, "Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: A comparison with fluoroscopy, " J. Am. Soc . Echocardi ogr., vol. 14, pp. 927-933, 2001.
    • (2001) J. Am. Soc . Echocardi ogr , vol.14 , pp. 927-933
    • McCreery, C.J.1    McCulloch, M.2    Ahmad, M.3    deFilippi, C.R.4
  • 19
  • 20
    • 0000996826 scopus 로고    scopus 로고
    • Identification of congenital heart defects using real time three-dimensional echo in pediatric patients
    • C. E. Fleishman, J. Li, T. Ota, C. J. Ohazama, G. Stetten, D. Adams, O. T. von Ramm, and J. Kisslo, "Identification of congenital heart defects using real time three-dimensional echo in pediatric patients, " Circulation, vol. 94 (Suppl. I), p. 416, 1996.
    • (1996) Circulation , vol.94 , Issue.SUPPL. I , pp. 416
    • Fleishman, C.E.1    Li, J.2    Ota, T.3    Ohazama, C.J.4    Stetten, G.5    Adams, D.6    von Ramm, O.T.7    Kisslo, J.8
  • 21
    • 34548082481 scopus 로고    scopus 로고
    • Analysis of a vibrating interventional device to improve 3-D colormark tracking
    • M. P. Fronheiser and S. W. Smith, "Analysis of a vibrating interventional device to improve 3-D colormark tracking, " IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 54, pp. 1700-1707, 2007.
    • (2007) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.54 , pp. 1700-1707
    • Fronheiser, M.P.1    Smith, S.W.2
  • 22
    • 0021829333 scopus 로고
    • Representations of rapidly oscillating structures on the Doppler display
    • J. Holen, R. C. Waag, and R. Gramiak, "Representations of rapidly oscillating structures on the Doppler display, " Ultrasound Med. Biol., vol. 11, pp. 267-272, 1985.
    • (1985) Ultrasound Med. Biol , vol.11 , pp. 267-272
    • Holen, J.1    Waag, R.C.2    Gramiak, R.3
  • 25
    • 0035909910 scopus 로고    scopus 로고
    • Use of intracardiac echocardiography to guide ablation of atrial fibrillation
    • J. Cooper and L. Epstein, "Use of intracardiac echocardiography to guide ablation of atrial fibrillation, " Circulation, vol. 104, pp. 3010-3013, 2001.
    • (2001) Circulation , vol.104 , pp. 3010-3013
    • Cooper, J.1    Epstein, L.2
  • 26
    • 0036742120 scopus 로고    scopus 로고
    • Phased-array intracardiac echocardiography during pulmonary vein isolation and linear ablation for atrial fibrillation
    • R. Martin, K. Ellenbogen, Y. Lau, J. Hall, G. Kay, R. Shepard, J. Nixon, and M. Wood, "Phased-array intracardiac echocardiography during pulmonary vein isolation and linear ablation for atrial fibrillation, " J. Cardiovasc. Electrophysiol., vol. 13, pp. 873-879, 2002.
    • (2002) J. Cardiovasc. Electrophysiol , vol.13 , pp. 873-879
    • Martin, R.1    Ellenbogen, K.2    Lau, Y.3    Hall, J.4    Kay, G.5    Shepard, R.6    Nixon, J.7    Wood, M.8
  • 27
    • 0035106286 scopus 로고    scopus 로고
    • Phased-array intracardiac echocardiography to guide radiofrequency ablation in the left atrium and at the pulmonary vein ostium
    • J. Morton, P. Sanders, M. Byrne, J. Power, C. Mow, G. Edwards, and J. Kalman, "Phased-array intracardiac echocardiography to guide radiofrequency ablation in the left atrium and at the pulmonary vein ostium, " J. Cardiovasc. Electrophysiol., vol. 12, pp. 343-348, 2001.
    • (2001) J. Cardiovasc. Electrophysiol , vol.12 , pp. 343-348
    • Morton, J.1    Sanders, P.2    Byrne, M.3    Power, J.4    Mow, C.5    Edwards, G.6    Kalman, J.7
  • 28
    • 18844466568 scopus 로고    scopus 로고
    • Primary cardiac lymphoma diagnosed with transesophageal echocardiography-guided endomyocardial biopsy
    • F. Burling, G. Devlin, and S. Heald, "Primary cardiac lymphoma diagnosed with transesophageal echocardiography-guided endomyocardial biopsy, " Circulation, vol. 101, pp. 179-181, 2000.
    • (2000) Circulation , vol.101 , pp. 179-181
    • Burling, F.1    Devlin, G.2    Heald, S.3
  • 29
    • 0022339319 scopus 로고
    • Endomyocardial biopsy in the United Kingdom
    • P. J. Richardson, "Endomyocardial biopsy in the United Kingdom, " Heart Vessels, vol. 1, pp. 83-85, 1985.
    • (1985) Heart Vessels , vol.1 , pp. 83-85
    • Richardson, P.J.1
  • 30
    • 37349014018 scopus 로고    scopus 로고
    • Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology, feasibility study
    • E. C. Pua, S. F. Idriss, P. D. Wolf, and S. W. Smith, "Real-time three-dimensional transesophageal echocardiography for guiding interventional electrophysiology, feasibility study, " Ultrason. Imag., vol. 29, pp. 182-194, 2007.
    • (2007) Ultrason. Imag , vol.29 , pp. 182-194
    • Pua, E.C.1    Idriss, S.F.2    Wolf, P.D.3    Smith, S.W.4
  • 31
    • 17644394942 scopus 로고    scopus 로고
    • Realtime 3-D transesophageal echocardiography
    • E. C. Pua, S. F. Idriss, P. D. Wolf, and S. W. Smith, "Realtime 3-D transesophageal echocardiography, " Ultrason. Imag., vol. 26, pp. 217-232, 2004.
    • (2004) Ultrason. Imag , vol.26 , pp. 217-232
    • Pua, E.C.1    Idriss, S.F.2    Wolf, P.D.3    Smith, S.W.4
  • 32
    • 0033295064 scopus 로고    scopus 로고
    • Update of two dimensional arrays for real time volumetric and real time intracardiac imaging,
    • E. D. Light, J. O. Fiering, P. A. Hultman, W. Lee, and S. W. Smith, "Update of two dimensional arrays for real time volumetric and real time intracardiac imaging, " in Proc. IEEE Ultrason. Symp., vol. 2, 1999, pp. 1217-1220.
    • (1999) Proc. IEEE Ultrason. Symp , vol.2 , pp. 1217-1220
    • Light, E.D.1    Fiering, J.O.2    Hultman, P.A.3    Lee, W.4    Smith, S.W.5
  • 34
    • 0025736942 scopus 로고
    • An efficient algorithm to remove low frequency Doppler signals in digital Doppler systems
    • A. P. G. Hoeks, J. J. W. van de Vorst, A. Dabekaussen, P. J. Brands, and R. S. Reneman, "An efficient algorithm to remove low frequency Doppler signals in digital Doppler systems, " Ultrason. Imag., vol. 13, pp. 135-144, 1991.
    • (1991) Ultrason. Imag , vol.13 , pp. 135-144
    • Hoeks, A.P.G.1    van de Vorst, J.J.W.2    Dabekaussen, A.3    Brands, P.J.4    Reneman, R.S.5
  • 35
    • 0027839734 scopus 로고
    • Deadbeat IIR based MTI filtering for color flow imaging systems,
    • M. A. Shariati, J. H. Dripps, and W. N. McDicken, "Deadbeat IIR based MTI filtering for color flow imaging systems, " in Proc. IEEE Ultrason. Symp., 1993, pp. 1059-1063.
    • (1993) Proc. IEEE Ultrason. Symp , pp. 1059-1063
    • Shariati, M.A.1    Dripps, J.H.2    McDicken, W.N.3
  • 36
    • 0024380426 scopus 로고
    • Bias and variance in the estimate of the Doppler frequency induced by a wall motion filter
    • J. C. Willemetz, A. Nowicki, J. J. Meister, F. De Palma, and G. Pante, "Bias and variance in the estimate of the Doppler frequency induced by a wall motion filter," Ultrason. Imag., vol. 11, pp. 215-225, 1989.
    • (1989) Ultrason. Imag , vol.11 , pp. 215-225
    • Willemetz, J.C.1    Nowicki, A.2    Meister, J.J.3    De Palma, F.4    Pante, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.