메뉴 건너뛰기




Volumn 43, Issue 2-6, 2008, Pages 392-396

Characterisation of radiophotoluminescent dosimeters for environmental monitoring

Author keywords

Energy dependence; Environmental monitoring; Glass dosimeters; IEC Standards; Light sensitivity; RPL

Indexed keywords

DOSIMETERS; ENVIRONMENTAL ENGINEERING; ENVIRONMENTAL MANAGEMENT; ENVIRONMENTAL PROTECTION; GLASS; MICROFLUIDICS; MONITORING; OFFSHORE OIL WELL PRODUCTION; OPTICAL PROPERTIES; PHOTOSENSITIVITY; STANDARDS; THERMOLUMINESCENCE;

EID: 44949180861     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2007.11.020     Document Type: Article
Times cited : (48)

References (12)
  • 1
    • 0345157424 scopus 로고    scopus 로고
    • New aspects of environmental monitoring using phosphate glass and thermoluminescence dosemeters
    • Burgkhardt B., Festag J.G., Piesch E., and Ugi S. New aspects of environmental monitoring using phosphate glass and thermoluminescence dosemeters. Radiat. Prot. Dosim. 66 1 (1996) 187-192
    • (1996) Radiat. Prot. Dosim. , vol.66 , Issue.1 , pp. 187-192
    • Burgkhardt, B.1    Festag, J.G.2    Piesch, E.3    Ugi, S.4
  • 2
    • 44949238708 scopus 로고    scopus 로고
    • Chiyoda Technol Corporation, 2007. 〈http://www.c-technol.co.jp/technol_eng/〉.
    • Chiyoda Technol Corporation, 2007. 〈http://www.c-technol.co.jp/technol_eng/〉.
  • 3
    • 33749653460 scopus 로고    scopus 로고
    • Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters
    • Hsu S.-M., Yeh S.-H., Lin M.-S., and Chen W.-l. Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters. Radiat. Prot. Dosim. 119 (2006) 327-331
    • (2006) Radiat. Prot. Dosim. , vol.119 , pp. 327-331
    • Hsu, S.-M.1    Yeh, S.-H.2    Lin, M.-S.3    Chen, W.-l.4
  • 4
    • 44949231340 scopus 로고    scopus 로고
    • IEC, International Electrotechnical Commission, 1991. Thermoluminescence dosimetry systems for personal and environmental monitoring. CEI/IEC International Standard 1066:1991.
    • IEC, International Electrotechnical Commission, 1991. Thermoluminescence dosimetry systems for personal and environmental monitoring. CEI/IEC International Standard 1066:1991.
  • 5
    • 44949222605 scopus 로고    scopus 로고
    • IEC, International Electrotechnical Commission, 2006. Thermoluminescence dosimetry systems for personal and environmental monitoring. CEI/IEC International Standard 61066:2006.
    • IEC, International Electrotechnical Commission, 2006. Thermoluminescence dosimetry systems for personal and environmental monitoring. CEI/IEC International Standard 61066:2006.
  • 6
    • 44949244123 scopus 로고    scopus 로고
    • ISO, International Organization for Standardization, 1999. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-part 3: calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence, Geneve, ISO 4037-3.
    • ISO, International Organization for Standardization, 1999. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy-part 3: calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence, Geneve, ISO 4037-3.
  • 7
    • 0036390540 scopus 로고    scopus 로고
    • Main dosimetric characteristics of some tissue-equivalent TL detectors
    • Miljanić S., Ranogajec-Komor M., Knežević Z., and Vekić B. Main dosimetric characteristics of some tissue-equivalent TL detectors. Radiat. Prot. Dosim. 100 1-4 (2002) 437-442
    • (2002) Radiat. Prot. Dosim. , vol.100 , Issue.1-4 , pp. 437-442
    • Miljanić, S.1    Ranogajec-Komor, M.2    Knežević, Z.3    Vekić, B.4
  • 8
    • 44949250947 scopus 로고    scopus 로고
    • Piesch, E., Burgkhardt, B., 1984. Environmental monitoring, European interlaboratory test programme for integrating dosemeter systems. Commission of the European Communities, Luxemburg, EUR 8932.
    • Piesch, E., Burgkhardt, B., 1984. Environmental monitoring, European interlaboratory test programme for integrating dosemeter systems. Commission of the European Communities, Luxemburg, EUR 8932.
  • 9
    • 34047182266 scopus 로고    scopus 로고
    • Thermoluminescence dosimetry-application in environmental dosimetry
    • Ranogajec-Komor M. Thermoluminescence dosimetry-application in environmental dosimetry. Radiat. Saf. Manage. 2 1 (2003) 2-16
    • (2003) Radiat. Saf. Manage. , vol.2 , Issue.1 , pp. 2-16
    • Ranogajec-Komor, M.1
  • 11
    • 0033847991 scopus 로고    scopus 로고
    • A catalogue of dosemeters and dosimetric services within EU member states and Switzerland able to estimate external radiation doses as personal dose equivalent
    • van Dijk J.W.E., Bordy J.M., Vanhavere F., Wernli C., and Zamani-Valasiadou M. A catalogue of dosemeters and dosimetric services within EU member states and Switzerland able to estimate external radiation doses as personal dose equivalent. Radiat. Prot. Dosim. 89 (2000) 53-105
    • (2000) Radiat. Prot. Dosim. , vol.89 , pp. 53-105
    • van Dijk, J.W.E.1    Bordy, J.M.2    Vanhavere, F.3    Wernli, C.4    Zamani-Valasiadou, M.5
  • 12
    • 33745597631 scopus 로고    scopus 로고
    • Secondary standard dosimetry laboratory at the Rud{combining short stroke overlay}er Bošković Institute
    • Vekić B., Ban R., and Miljanić S. Secondary standard dosimetry laboratory at the Rud{combining short stroke overlay}er Bošković Institute. Arh. Hig. Rada Toksikol. 57 (2006) 189-194
    • (2006) Arh. Hig. Rada Toksikol. , vol.57 , pp. 189-194
    • Vekić, B.1    Ban, R.2    Miljanić, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.