메뉴 건너뛰기




Volumn 94, Issue 4, 2008, Pages 382-391

Functional range of motion of the hip joint;La mobilité fonctionnelle de l'articulation de la hanche

Author keywords

Arthroplasty; Biomechanics; Hip; Kinematics; Prosthesis; Range of motion

Indexed keywords

ADULT; ARTICLE; FEMALE; HIP; HUMAN; JOINT CHARACTERISTICS AND FUNCTIONS; MALE; PHYSIOLOGY; THEORETICAL MODEL;

EID: 44949138933     PISSN: 00351040     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rco.2007.08.001     Document Type: Article
Times cited : (9)

References (22)
  • 1
    • 0029449284 scopus 로고
    • Variations intra- et interindividuelles de la mobilité pelvienne au cours de la marche du sujet sain
    • Dujardin F., Selva O., Mejjad O., Pasero D., Piraux J.L., and Thomine J.M. Variations intra- et interindividuelles de la mobilité pelvienne au cours de la marche du sujet sain. Rev Chir Orthop 81 (1995) 592-600
    • (1995) Rev Chir Orthop , vol.81 , pp. 592-600
    • Dujardin, F.1    Selva, O.2    Mejjad, O.3    Pasero, D.4    Piraux, J.L.5    Thomine, J.M.6
  • 2
    • 0034797485 scopus 로고    scopus 로고
    • Walking velocity in aged persons: its association with lower extremity joint range of motion
    • Escalante A., Lichtenstein M.J., and Hazuda H.P. Walking velocity in aged persons: its association with lower extremity joint range of motion. Arthritis Rheum 45 (2001) 287-294
    • (2001) Arthritis Rheum , vol.45 , pp. 287-294
    • Escalante, A.1    Lichtenstein, M.J.2    Hazuda, H.P.3
  • 3
    • 0026531833 scopus 로고
    • Impingement and loosening of the long posterior wall acetabular implant
    • Murray D.W. Impingement and loosening of the long posterior wall acetabular implant. J Bone Joint Surg Br 74 (1992) 377-379
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 377-379
    • Murray, D.W.1
  • 4
    • 20444399895 scopus 로고    scopus 로고
    • Salvati EA: Impingement in total hip arthroplasty a study of retrieved acetabular components
    • Shon W.Y., Baldini T., Peterson M.G., and Wright T.M. Salvati EA: Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty 20 (2005) 427-435
    • (2005) J Arthroplasty , vol.20 , pp. 427-435
    • Shon, W.Y.1    Baldini, T.2    Peterson, M.G.3    Wright, T.M.4
  • 5
    • 0018630253 scopus 로고
    • L'étude électromyographique de la marche et de la fonction automatique de la musculature en orthopédie
    • Taillard W., and Blanc Y. L'étude électromyographique de la marche et de la fonction automatique de la musculature en orthopédie. Brux Med 59 (1979) 419-434
    • (1979) Brux Med , vol.59 , pp. 419-434
    • Taillard, W.1    Blanc, Y.2
  • 6
    • 0014848095 scopus 로고
    • Hip motion measurements for selected activities of daily living
    • Johnston R.C., and Smidt G.L. Hip motion measurements for selected activities of daily living. Clin Orthop 72 (1970) 205-215
    • (1970) Clin Orthop , vol.72 , pp. 205-215
    • Johnston, R.C.1    Smidt, G.L.2
  • 8
    • 44949131909 scopus 로고    scopus 로고
    • Étude des fonctionnalités du membre supérieur en mouvement par l'exploitation de trajectoires de marqueurs externes
    • Gutierrez C. Étude des fonctionnalités du membre supérieur en mouvement par l'exploitation de trajectoires de marqueurs externes. Thèse Lyon : Mécanique 259 (1996) 44-75
    • (1996) Thèse Lyon : Mécanique , vol.259 , pp. 44-75
    • Gutierrez, C.1
  • 9
    • 28844482901 scopus 로고    scopus 로고
    • Detection of the center of the hip joint in computer-assisted surgery: An evaluation study of the Surgetics algorithm
    • Stindel E., Gil D., Briard J.L., Merloz P., Dubrana F., and Lefevre C. Detection of the center of the hip joint in computer-assisted surgery: An evaluation study of the Surgetics algorithm. Comput Aided Surg 10 (2005) 133-139
    • (2005) Comput Aided Surg , vol.10 , pp. 133-139
    • Stindel, E.1    Gil, D.2    Briard, J.L.3    Merloz, P.4    Dubrana, F.5    Lefevre, C.6
  • 10
    • 0024929110 scopus 로고
    • A three-dimensional musculoskeletal model for gait analysis. Anatomical variability estimates
    • White S.C., Yack H.J., and Winter D.A. A three-dimensional musculoskeletal model for gait analysis. Anatomical variability estimates. J Biomech 22 (1989) 885-893
    • (1989) J Biomech , vol.22 , pp. 885-893
    • White, S.C.1    Yack, H.J.2    Winter, D.A.3
  • 11
    • 0036207866 scopus 로고    scopus 로고
    • ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion-part I: ankle, hip, and spine. International Society of Biomechanics
    • Wu G., Siegler S., Allard P., Kirtley C., Leardini A., Rosenbaum D., et al. ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion-part I: ankle, hip, and spine. International Society of Biomechanics. J Biomech 35 (2002) 543-548
    • (2002) J Biomech , vol.35 , pp. 543-548
    • Wu, G.1    Siegler, S.2    Allard, P.3    Kirtley, C.4    Leardini, A.5    Rosenbaum, D.6
  • 12
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray D.W. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75 (1993) 228-232
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 228-232
    • Murray, D.W.1
  • 14
    • 0030111274 scopus 로고    scopus 로고
    • Position and orientation in space of bones during movement: experimental artefacts
    • Cappozzo A., Catani F., Leardini A., Benedetti M.G., and Croce U.D. Position and orientation in space of bones during movement: experimental artefacts. Clin Biomech 11 (1996) 90-100
    • (1996) Clin Biomech , vol.11 , pp. 90-100
    • Cappozzo, A.1    Catani, F.2    Leardini, A.3    Benedetti, M.G.4    Croce, U.D.5
  • 15
    • 44949231478 scopus 로고    scopus 로고
    • Expansion Scientifique, Paris p. 281-298
    • Dujardin F. Étude de la marche au laboratoire. Implications et perspectives cliniques. Cahier d'enseignement de la SOFCOT 62 (1997), Expansion Scientifique, Paris p. 281-298
    • (1997) Cahier d'enseignement de la SOFCOT , vol.62
    • Dujardin, F.1
  • 16
    • 0034868709 scopus 로고    scopus 로고
    • Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants
    • Mulholland S.J., and Wyss U.P. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res 24 (2001) 191-198
    • (2001) Int J Rehabil Res , vol.24 , pp. 191-198
    • Mulholland, S.J.1    Wyss, U.P.2
  • 17
    • 0036727157 scopus 로고    scopus 로고
    • Determinants of the sit-to-stand movement: a review
    • Janssen W.G., Bussmann H.B., and Stam H.J. Determinants of the sit-to-stand movement: a review. Phys Ther 82 (2002) 866-879
    • (2002) Phys Ther , vol.82 , pp. 866-879
    • Janssen, W.G.1    Bussmann, H.B.2    Stam, H.J.3
  • 18
    • 0036274229 scopus 로고    scopus 로고
    • A mathematical formula to calculate the theoretical range of motion for total hip replacement
    • Yoshimine F., and Ginbayashi K. A mathematical formula to calculate the theoretical range of motion for total hip replacement. J Biomech 35 (2002) 989-993
    • (2002) J Biomech , vol.35 , pp. 989-993
    • Yoshimine, F.1    Ginbayashi, K.2
  • 19
    • 33646067166 scopus 로고    scopus 로고
    • The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements
    • Yoshimine F. The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech 39 (2006) 1315-1323
    • (2006) J Biomech , vol.39 , pp. 1315-1323
    • Yoshimine, F.1
  • 20
    • 7044236774 scopus 로고    scopus 로고
    • The influence of the oscillation angle and the neck anteversion of the prosthesis on the cup safe-zone that fulfills the criteria for range of motion in total hip replacements. The required oscillation angle for an acceptable cup safe-zone
    • Yoshimine F. The influence of the oscillation angle and the neck anteversion of the prosthesis on the cup safe-zone that fulfills the criteria for range of motion in total hip replacements. The required oscillation angle for an acceptable cup safe-zone. J Biomech 38 (2005) 125-132
    • (2005) J Biomech , vol.38 , pp. 125-132
    • Yoshimine, F.1
  • 21
    • 4444364365 scopus 로고    scopus 로고
    • Reduced variability of acetabular cup positioning with use of an imageless navigation system
    • Nogler M., Kessler O., Prassl A., Donnelly B., Streicher R., Sledge J.B., et al. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop (2004) 159-163
    • (2004) Clin Orthop , pp. 159-163
    • Nogler, M.1    Kessler, O.2    Prassl, A.3    Donnelly, B.4    Streicher, R.5    Sledge, J.B.6
  • 22
    • 33745155065 scopus 로고    scopus 로고
    • Positionnement de la cupule d'une prothèse totale de hanche par navigation sans image basée sur la cinématique articulaire. Premiers résultats avec évaluation tomodensitométrique de l'orientation des implants
    • Laffargue P., Pinoit Y., Tabutin J., Giraud F., Puget J., and Migaud H. Positionnement de la cupule d'une prothèse totale de hanche par navigation sans image basée sur la cinématique articulaire. Premiers résultats avec évaluation tomodensitométrique de l'orientation des implants. Rev Chir Orthop 92 (2006) 316-325
    • (2006) Rev Chir Orthop , vol.92 , pp. 316-325
    • Laffargue, P.1    Pinoit, Y.2    Tabutin, J.3    Giraud, F.4    Puget, J.5    Migaud, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.