메뉴 건너뛰기




Volumn 47, Issue 9-10, 2008, Pages 1765-1770

Wire mesh tomography applied to trickle beds: A new way to study liquid maldistribution

Author keywords

Liquid distribution; Metrology; Trickle bed

Indexed keywords

CHEMICAL SENSORS; CONCENTRATION (PROCESS); ELECTRODES; PARAMETER ESTIMATION;

EID: 44949129956     PISSN: 02552701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cep.2007.09.017     Document Type: Article
Times cited : (27)

References (10)
  • 1
    • 0032100908 scopus 로고    scopus 로고
    • A new electrode-mesh tomograph for gas-liquid flows
    • Prasser H.-M., Böttger A., and Zschau J. A new electrode-mesh tomograph for gas-liquid flows. Flow Meas. Instrum. 9 (1998) 111-119
    • (1998) Flow Meas. Instrum. , vol.9 , pp. 111-119
    • Prasser, H.-M.1    Böttger, A.2    Zschau, J.3
  • 3
    • 0031421715 scopus 로고    scopus 로고
    • Liquid flow texture in trickle-bed reactors: an experimental study
    • Ravindra P.V., Rao D.P., and Rao M.S. Liquid flow texture in trickle-bed reactors: an experimental study. Ind. Eng. Chem. Res. 36 (1997) 5133-5145
    • (1997) Ind. Eng. Chem. Res. , vol.36 , pp. 5133-5145
    • Ravindra, P.V.1    Rao, D.P.2    Rao, M.S.3
  • 4
    • 22744443465 scopus 로고    scopus 로고
    • Study of liquid spreading from a point source in a trickle bed via gamma-ray tomography and CFD simulation
    • Boyer C., Koudil A., Chen P., and Dudukovic M.P. Study of liquid spreading from a point source in a trickle bed via gamma-ray tomography and CFD simulation. Chem. Eng. Sci. 60 (2005) 6279-6288
    • (2005) Chem. Eng. Sci. , vol.60 , pp. 6279-6288
    • Boyer, C.1    Koudil, A.2    Chen, P.3    Dudukovic, M.P.4
  • 5
    • 0032705310 scopus 로고    scopus 로고
    • Investigation of liquid maldistribution in packed columns by X-ray tomography
    • Marchot P., Toye D., Crine M., Pelsser A.-M., and L'Homme G. Investigation of liquid maldistribution in packed columns by X-ray tomography. Trans. Inst. Chem. Eng. 77 (1999) 511-518
    • (1999) Trans. Inst. Chem. Eng. , vol.77 , pp. 511-518
    • Marchot, P.1    Toye, D.2    Crine, M.3    Pelsser, A.-M.4    L'Homme, G.5
  • 6
    • 22744457996 scopus 로고    scopus 로고
    • Application of magnetic resonance imagining (MRI) for investigation of fluid dynamics in trickle bed reactors and of droplet separation kinetics in packed beds
    • Nguyen N.L., van Buren V., von Garnier A., Hardy E.H., and Reimert R. Application of magnetic resonance imagining (MRI) for investigation of fluid dynamics in trickle bed reactors and of droplet separation kinetics in packed beds. Chem. Eng. Sci. 60 (2005) 6289-6297
    • (2005) Chem. Eng. Sci. , vol.60 , pp. 6289-6297
    • Nguyen, N.L.1    van Buren, V.2    von Garnier, A.3    Hardy, E.H.4    Reimert, R.5
  • 7
    • 0036668920 scopus 로고    scopus 로고
    • Measuring techniques in gas-liquid and gas-liquid-solid reactors
    • Boyer C., Duquenne A.-M., and Wild G. Measuring techniques in gas-liquid and gas-liquid-solid reactors. Chem. Eng. Sci. 57 (2002) 3185-3215
    • (2002) Chem. Eng. Sci. , vol.57 , pp. 3185-3215
    • Boyer, C.1    Duquenne, A.-M.2    Wild, G.3
  • 8
    • 0030616236 scopus 로고    scopus 로고
    • Investigation of the two-phase flow in trickle-bed reactors using capacitance tomography
    • Reinecke N., and Mewes D. Investigation of the two-phase flow in trickle-bed reactors using capacitance tomography. Chem. Eng. Sci. 52 (1997) 2111-2127
    • (1997) Chem. Eng. Sci. , vol.52 , pp. 2111-2127
    • Reinecke, N.1    Mewes, D.2
  • 9
    • 22744446753 scopus 로고    scopus 로고
    • Dynamics of spiral bubble plume motion in the entrance region of bubble columns and three-phase fluidized beds using 3D ECT
    • Warsito W., and Fan L.S. Dynamics of spiral bubble plume motion in the entrance region of bubble columns and three-phase fluidized beds using 3D ECT. Chem. Eng. Sci. 60 (2005) 6073-6084
    • (2005) Chem. Eng. Sci. , vol.60 , pp. 6073-6084
    • Warsito, W.1    Fan, L.S.2
  • 10
    • 44949242821 scopus 로고    scopus 로고
    • I.D. Johnson, U.S. patent, No. 4,644,263 (1987).
    • I.D. Johnson, U.S. patent, No. 4,644,263 (1987).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.